ABAP Select data from SAP table EHFNDW_SRAUTOIGN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDW_SRAUTOIGN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDW_SRAUTOIGN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDW_SRAUTOIGN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDW_SRAUTOIGN TYPE STANDARD TABLE OF EHFNDW_SRAUTOIGN,
      WA_EHFNDW_SRAUTOIGN TYPE EHFNDW_SRAUTOIGN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDW_SRAUTOIGN> TYPE EHFNDW_SRAUTOIGN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDW_SRAUTOIGN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDW_SRAUTOIGN
  INTO TABLE IT_EHFNDW_SRAUTOIGN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDW_SRAUTOIGN
*  INTO TABLE @DATA(IT_EHFNDW_SRAUTOIGN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDW_SRAUTOIGN INDEX 1 INTO DATA(WA_EHFNDW_SRAUTOIGN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDW_SRAUTOIGN ASSIGNING <EHFNDW_SRAUTOIGN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDW_SRAUTOIGN>-MANDT = 1.
<EHFNDW_SRAUTOIGN>-PCSFTYAUTOIGNTNPRPTYUUID = 1.
<EHFNDW_SRAUTOIGN>-PCSFTYPRPTYUUID = 1.
<EHFNDW_SRAUTOIGN>-CREATIONUTCDATETIME = 1.
<EHFNDW_SRAUTOIGN>-CREATEDBYUSER = 1.
ENDLOOP.

LOOP AT IT_EHFNDW_SRAUTOIGN INTO WA_EHFNDW_SRAUTOIGN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDW_SRAUTOIGN-LASTCHANGEUTCDATETIME, sy-vline,
WA_EHFNDW_SRAUTOIGN-LASTCHANGEDBYUSER, sy-vline,
WA_EHFNDW_SRAUTOIGN-PCSFTYAUTOIGNTNTEMPLOWRQTYOPTR, sy-vline,
WA_EHFNDW_SRAUTOIGN-PCSFTYAUTOIGNTNTEMPLOWRQTY, sy-vline,
WA_EHFNDW_SRAUTOIGN-PCSFTYAUTOIGNTNTEMPLOWRQTYTXT, sy-vline,
WA_EHFNDW_SRAUTOIGN-PCSFTYAUTOIGNTNTEMPUPRQTYOPTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDW_SRAUTOIGN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDW_SRAUTOIGN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDW_SRAUTOIGN INTO WA_EHFNDW_SRAUTOIGN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field PCSFTYAUTOIGNTNTEMPQTYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDW_SRAUTOIGN-PCSFTYAUTOIGNTNTEMPQTYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDW_SRAUTOIGN-PCSFTYAUTOIGNTNTEMPQTYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDW_SRAUTOIGN_STR,
MANDT TYPE STRING,
PCSFTYAUTOIGNTNPRPTYUUID TYPE STRING,
PCSFTYPRPTYUUID TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
PCSFTYAUTOIGNTNTEMPLOWRQTYOPTR TYPE STRING,
PCSFTYAUTOIGNTNTEMPLOWRQTY TYPE STRING,
PCSFTYAUTOIGNTNTEMPLOWRQTYTXT TYPE STRING,
PCSFTYAUTOIGNTNTEMPUPRQTYOPTR TYPE STRING,
PCSFTYAUTOIGNTNTEMPUPRQTY TYPE STRING,
PCSFTYAUTOIGNTNTEMPUPRQTYTXT TYPE STRING,
PCSFTYAUTOIGNTNTEMPQTYUNIT TYPE STRING,
PCSFTYNOTETEXT TYPE STRING,
PCSFTYHASNOAPPL TYPE STRING,
PCSFTYHASNODATA TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDW_SRAUTOIGN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDW_SRAUTOIGN_STR-MANDT sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYAUTOIGNTNPRPTYUUID sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYPRPTYUUID sy-vline
WA_EHFNDW_SRAUTOIGN_STR-CREATIONUTCDATETIME sy-vline
WA_EHFNDW_SRAUTOIGN_STR-CREATEDBYUSER sy-vline
WA_EHFNDW_SRAUTOIGN_STR-LASTCHANGEUTCDATETIME sy-vline
WA_EHFNDW_SRAUTOIGN_STR-LASTCHANGEDBYUSER sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYAUTOIGNTNTEMPLOWRQTYOPTR sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYAUTOIGNTNTEMPLOWRQTY sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYAUTOIGNTNTEMPLOWRQTYTXT sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYAUTOIGNTNTEMPUPRQTYOPTR sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYAUTOIGNTNTEMPUPRQTY sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYAUTOIGNTNTEMPUPRQTYTXT sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYAUTOIGNTNTEMPQTYUNIT sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYNOTETEXT sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYHASNOAPPL sy-vline
WA_EHFNDW_SRAUTOIGN_STR-PCSFTYHASNODATA sy-vline
WA_EHFNDW_SRAUTOIGN_STR-ACTIVEUUID sy-vline
WA_EHFNDW_SRAUTOIGN_STR-HASACTIVEENTITY sy-vline
WA_EHFNDW_SRAUTOIGN_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_EHFNDW_SRAUTOIGN_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_EHFNDW_SRAUTOIGN_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_EHFNDW_SRAUTOIGN_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_EHFNDW_SRAUTOIGN_STR-DRAFTENTITYOPERATIONCODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.