ABAP Select data from SAP table EHFNDS_REQ_REG_LIST_QRY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDS_REQ_REG_LIST_QRY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDS_REQ_REG_LIST_QRY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDS_REQ_REG_LIST_QRY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDS_REQ_REG_LIST_QRY TYPE STANDARD TABLE OF EHFNDS_REQ_REG_LIST_QRY,
      WA_EHFNDS_REQ_REG_LIST_QRY TYPE EHFNDS_REQ_REG_LIST_QRY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDS_REQ_REG_LIST_QRY> TYPE EHFNDS_REQ_REG_LIST_QRY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDS_REQ_REG_LIST_QRY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDS_REQ_REG_LIST_QRY
  INTO TABLE IT_EHFNDS_REQ_REG_LIST_QRY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDS_REQ_REG_LIST_QRY
*  INTO TABLE @DATA(IT_EHFNDS_REQ_REG_LIST_QRY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDS_REQ_REG_LIST_QRY INDEX 1 INTO DATA(WA_EHFNDS_REQ_REG_LIST_QRY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDS_REQ_REG_LIST_QRY ASSIGNING <EHFNDS_REQ_REG_LIST_QRY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDS_REQ_REG_LIST_QRY>-DATE = 1.
<EHFNDS_REQ_REG_LIST_QRY>-TITLE = 1.
<EHFNDS_REQ_REG_LIST_QRY>-REGLIST_NAME = 1.
<EHFNDS_REQ_REG_LIST_QRY>-NAME = 1.
<EHFNDS_REQ_REG_LIST_QRY>-CAS_NUMBER = 1.
ENDLOOP.

LOOP AT IT_EHFNDS_REQ_REG_LIST_QRY INTO WA_EHFNDS_REQ_REG_LIST_QRY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDS_REQ_REG_LIST_QRY-ADD_INFO, sy-vline,
WA_EHFNDS_REQ_REG_LIST_QRY-POLUTANT_NAME, sy-vline,
WA_EHFNDS_REQ_REG_LIST_QRY-POLUTANT_CAS_NO, sy-vline,
WA_EHFNDS_REQ_REG_LIST_QRY-REGLIST_TYPE, sy-vline,
WA_EHFNDS_REQ_REG_LIST_QRY-NAME_COMB, sy-vline,
WA_EHFNDS_REQ_REG_LIST_QRY-CAS_NUM_COMB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDS_REQ_REG_LIST_QRY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDS_REQ_REG_LIST_QRY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDS_REQ_REG_LIST_QRY INTO WA_EHFNDS_REQ_REG_LIST_QRY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit RLTYP, internal->external for field REGLIST_TYPE CALL FUNCTION 'CONVERSION_EXIT_RLTYP_OUTPUT' EXPORTING input = WA_EHFNDS_REQ_REG_LIST_QRY-REGLIST_TYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_REQ_REG_LIST_QRY-REGLIST_TYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CSFNM, internal->external for field CLSF_ROOT_KEY_REF CALL FUNCTION 'CONVERSION_EXIT_CSFNM_OUTPUT' EXPORTING input = WA_EHFNDS_REQ_REG_LIST_QRY-CLSF_ROOT_KEY_REF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_REQ_REG_LIST_QRY-CLSF_ROOT_KEY_REF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHPHY, internal->external for field PROPERTY_KEY_REF CALL FUNCTION 'CONVERSION_EXIT_EHPHY_OUTPUT' EXPORTING input = WA_EHFNDS_REQ_REG_LIST_QRY-PROPERTY_KEY_REF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_REQ_REG_LIST_QRY-PROPERTY_KEY_REF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDS_REQ_REG_LIST_QRY_STR,
DATE TYPE STRING,
TITLE TYPE STRING,
REGLIST_NAME TYPE STRING,
NAME TYPE STRING,
CAS_NUMBER TYPE STRING,
ADD_INFO TYPE STRING,
POLUTANT_NAME TYPE STRING,
POLUTANT_CAS_NO TYPE STRING,
REGLIST_TYPE TYPE STRING,
NAME_COMB TYPE STRING,
CAS_NUM_COMB TYPE STRING,
CLSF_ROOT_KEY_REF TYPE STRING,
PROPERTY_KEY_REF TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDS_REQ_REG_LIST_QRY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-DATE sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-TITLE sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-REGLIST_NAME sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-NAME sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-CAS_NUMBER sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-ADD_INFO sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-POLUTANT_NAME sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-POLUTANT_CAS_NO sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-REGLIST_TYPE sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-NAME_COMB sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-CAS_NUM_COMB sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-CLSF_ROOT_KEY_REF sy-vline
WA_EHFNDS_REQ_REG_LIST_QRY_STR-PROPERTY_KEY_REF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.