ABAP Select data from SAP table EHFNDS_INC_GRC_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDS_INC_GRC_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDS_INC_GRC_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDS_INC_GRC_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDS_INC_GRC_DATA TYPE STANDARD TABLE OF EHFNDS_INC_GRC_DATA,
      WA_EHFNDS_INC_GRC_DATA TYPE EHFNDS_INC_GRC_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDS_INC_GRC_DATA> TYPE EHFNDS_INC_GRC_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDS_INC_GRC_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDS_INC_GRC_DATA
  INTO TABLE IT_EHFNDS_INC_GRC_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDS_INC_GRC_DATA
*  INTO TABLE @DATA(IT_EHFNDS_INC_GRC_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDS_INC_GRC_DATA INDEX 1 INTO DATA(WA_EHFNDS_INC_GRC_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDS_INC_GRC_DATA ASSIGNING <EHFNDS_INC_GRC_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDS_INC_GRC_DATA>-INCIDENT_ID = 1.
<EHFNDS_INC_GRC_DATA>-ORGUNIT_ID = 1.
<EHFNDS_INC_GRC_DATA>-TXT = 1.
<EHFNDS_INC_GRC_DATA>-DESCR = 1.
<EHFNDS_INC_GRC_DATA>-IDENT_DATE = 1.
ENDLOOP.

LOOP AT IT_EHFNDS_INC_GRC_DATA INTO WA_EHFNDS_INC_GRC_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDS_INC_GRC_DATA-EVENT_DATE, sy-vline,
WA_EHFNDS_INC_GRC_DATA-EXT_REF, sy-vline,
WA_EHFNDS_INC_GRC_DATA-DOC_TICKET, sy-vline,
WA_EHFNDS_INC_GRC_DATA-PROCESSOR, sy-vline,
WA_EHFNDS_INC_GRC_DATA-STATUS, sy-vline,
WA_EHFNDS_INC_GRC_DATA-LOG_USERCRE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDS_INC_GRC_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDS_INC_GRC_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDS_INC_GRC_DATA INTO WA_EHFNDS_INC_GRC_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit DATLO, internal->external for field IDENT_DATE CALL FUNCTION 'CONVERSION_EXIT_DATLO_OUTPUT' EXPORTING input = WA_EHFNDS_INC_GRC_DATA-IDENT_DATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_INC_GRC_DATA-IDENT_DATE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit DATLO, internal->external for field EVENT_DATE CALL FUNCTION 'CONVERSION_EXIT_DATLO_OUTPUT' EXPORTING input = WA_EHFNDS_INC_GRC_DATA-EVENT_DATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_INC_GRC_DATA-EVENT_DATE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field LOG_TIMECRE CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHFNDS_INC_GRC_DATA-LOG_TIMECRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_INC_GRC_DATA-LOG_TIMECRE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field LOG_TIMECHA CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHFNDS_INC_GRC_DATA-LOG_TIMECHA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_INC_GRC_DATA-LOG_TIMECHA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field LOG_TIMEVAL CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHFNDS_INC_GRC_DATA-LOG_TIMEVAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_INC_GRC_DATA-LOG_TIMEVAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDS_INC_GRC_DATA_STR,
INCIDENT_ID TYPE STRING,
ORGUNIT_ID TYPE STRING,
TXT TYPE STRING,
DESCR TYPE STRING,
IDENT_DATE TYPE STRING,
EVENT_DATE TYPE STRING,
EXT_REF TYPE STRING,
DOC_TICKET TYPE STRING,
PROCESSOR TYPE STRING,
STATUS TYPE STRING,
LOG_USERCRE TYPE STRING,
LOG_TIMECRE TYPE STRING,
LOG_USERCHA TYPE STRING,
LOG_TIMECHA TYPE STRING,
LOG_USERVAL TYPE STRING,
LOG_TIMEVAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDS_INC_GRC_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-INCIDENT_ID sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-ORGUNIT_ID sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-TXT sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-DESCR sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-IDENT_DATE sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-EVENT_DATE sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-EXT_REF sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-DOC_TICKET sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-PROCESSOR sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-STATUS sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-LOG_USERCRE sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-LOG_TIMECRE sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-LOG_USERCHA sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-LOG_TIMECHA sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-LOG_USERVAL sy-vline
WA_EHFNDS_INC_GRC_DATA_STR-LOG_TIMEVAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.