ABAP Select data from SAP table EHFNDS_FW_WFF_REP_ANA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDS_FW_WFF_REP_ANA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDS_FW_WFF_REP_ANA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDS_FW_WFF_REP_ANA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDS_FW_WFF_REP_ANA TYPE STANDARD TABLE OF EHFNDS_FW_WFF_REP_ANA,
      WA_EHFNDS_FW_WFF_REP_ANA TYPE EHFNDS_FW_WFF_REP_ANA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDS_FW_WFF_REP_ANA> TYPE EHFNDS_FW_WFF_REP_ANA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDS_FW_WFF_REP_ANA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDS_FW_WFF_REP_ANA
  INTO TABLE IT_EHFNDS_FW_WFF_REP_ANA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDS_FW_WFF_REP_ANA
*  INTO TABLE @DATA(IT_EHFNDS_FW_WFF_REP_ANA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDS_FW_WFF_REP_ANA INDEX 1 INTO DATA(WA_EHFNDS_FW_WFF_REP_ANA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDS_FW_WFF_REP_ANA ASSIGNING <EHFNDS_FW_WFF_REP_ANA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDS_FW_WFF_REP_ANA>-EHSM_COMP = 1.
<EHFNDS_FW_WFF_REP_ANA>-VARIANT = 1.
<EHFNDS_FW_WFF_REP_ANA>-PURPOSE = 1.
<EHFNDS_FW_WFF_REP_ANA>-DESCRIPTION = 1.
<EHFNDS_FW_WFF_REP_ANA>-MONTH_YEAR = 1.
ENDLOOP.

LOOP AT IT_EHFNDS_FW_WFF_REP_ANA INTO WA_EHFNDS_FW_WFF_REP_ANA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDS_FW_WFF_REP_ANA-CLOSED_PROCESSES, sy-vline,
WA_EHFNDS_FW_WFF_REP_ANA-OPEN_PROCESSES, sy-vline,
WA_EHFNDS_FW_WFF_REP_ANA-OVERDUE, sy-vline,
WA_EHFNDS_FW_WFF_REP_ANA-DESC_STEP, sy-vline,
WA_EHFNDS_FW_WFF_REP_ANA-KEY, sy-vline,
WA_EHFNDS_FW_WFF_REP_ANA-TEMP_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDS_FW_WFF_REP_ANA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDS_FW_WFF_REP_ANA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDS_FW_WFF_REP_ANA INTO WA_EHFNDS_FW_WFF_REP_ANA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDS_FW_WFF_REP_ANA_STR,
EHSM_COMP TYPE STRING,
VARIANT TYPE STRING,
PURPOSE TYPE STRING,
DESCRIPTION TYPE STRING,
MONTH_YEAR TYPE STRING,
CLOSED_PROCESSES TYPE STRING,
OPEN_PROCESSES TYPE STRING,
OVERDUE TYPE STRING,
DESC_STEP TYPE STRING,
KEY TYPE STRING,
TEMP_ID TYPE STRING,
NODE_ID TYPE STRING,
AGE TYPE STRING,
RANGE TYPE STRING,
RANGE_IDX TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDS_FW_WFF_REP_ANA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-EHSM_COMP sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-VARIANT sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-PURPOSE sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-DESCRIPTION sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-MONTH_YEAR sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-CLOSED_PROCESSES sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-OPEN_PROCESSES sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-OVERDUE sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-DESC_STEP sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-KEY sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-TEMP_ID sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-NODE_ID sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-AGE sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-RANGE sy-vline
WA_EHFNDS_FW_WFF_REP_ANA_STR-RANGE_IDX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.