ABAP Select data from SAP table EHFNDS_DTS_ROOT_DT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDS_DTS_ROOT_DT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDS_DTS_ROOT_DT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDS_DTS_ROOT_DT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDS_DTS_ROOT_DT TYPE STANDARD TABLE OF EHFNDS_DTS_ROOT_DT,
      WA_EHFNDS_DTS_ROOT_DT TYPE EHFNDS_DTS_ROOT_DT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDS_DTS_ROOT_DT> TYPE EHFNDS_DTS_ROOT_DT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDS_DTS_ROOT_DT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDS_DTS_ROOT_DT
  INTO TABLE IT_EHFNDS_DTS_ROOT_DT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDS_DTS_ROOT_DT
*  INTO TABLE @DATA(IT_EHFNDS_DTS_ROOT_DT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDS_DTS_ROOT_DT INDEX 1 INTO DATA(WA_EHFNDS_DTS_ROOT_DT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDS_DTS_ROOT_DT ASSIGNING <EHFNDS_DTS_ROOT_DT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDS_DTS_ROOT_DT>-STATUS_DESC = 1.
<EHFNDS_DTS_ROOT_DT>-IS_INITIALIZED = 1.
<EHFNDS_DTS_ROOT_DT>-DIMENSION = 1.
<EHFNDS_DTS_ROOT_DT>-DIMENSION_DESC = 1.
<EHFNDS_DTS_ROOT_DT>-FACTOR_NAME = 1.
ENDLOOP.

LOOP AT IT_EHFNDS_DTS_ROOT_DT INTO WA_EHFNDS_DTS_ROOT_DT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDS_DTS_ROOT_DT-UNIT_DESC, sy-vline,
WA_EHFNDS_DTS_ROOT_DT-SAMP_TYPE_DESC, sy-vline,
WA_EHFNDS_DTS_ROOT_DT-LOC_ROOT_NAME_REF, sy-vline,
WA_EHFNDS_DTS_ROOT_DT-EEW_DTS_ROOT_DT, sy-vline,
WA_EHFNDS_DTS_ROOT_DT-HAZARD, sy-vline,
WA_EHFNDS_DTS_ROOT_DT-JOB_DESC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDS_DTS_ROOT_DT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDS_DTS_ROOT_DT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDS_DTS_ROOT_DT INTO WA_EHFNDS_DTS_ROOT_DT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit DIM, internal->external for field DIMENSION CALL FUNCTION 'CONVERSION_EXIT_DIM_OUTPUT' EXPORTING input = WA_EHFNDS_DTS_ROOT_DT-DIMENSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_DTS_ROOT_DT-DIMENSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHHAZ, internal->external for field HAZARD CALL FUNCTION 'CONVERSION_EXIT_EHHAZ_OUTPUT' EXPORTING input = WA_EHFNDS_DTS_ROOT_DT-HAZARD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_DTS_ROOT_DT-HAZARD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHACD, internal->external for field AGENT_COMBINED_KEY_REF CALL FUNCTION 'CONVERSION_EXIT_EHACD_OUTPUT' EXPORTING input = WA_EHFNDS_DTS_ROOT_DT-AGENT_COMBINED_KEY_REF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDS_DTS_ROOT_DT-AGENT_COMBINED_KEY_REF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDS_DTS_ROOT_DT_STR,
STATUS_DESC TYPE STRING,
IS_INITIALIZED TYPE STRING,
DIMENSION TYPE STRING,
DIMENSION_DESC TYPE STRING,
FACTOR_NAME TYPE STRING,
UNIT_DESC TYPE STRING,
SAMP_TYPE_DESC TYPE STRING,
LOC_ROOT_NAME_REF TYPE STRING,
EEW_DTS_ROOT_DT TYPE STRING,
HAZARD TYPE STRING,
JOB_DESC TYPE STRING,
AGENT_DESC TYPE STRING,
AGENT_COMBINED_KEY_REF TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDS_DTS_ROOT_DT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-STATUS_DESC sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-IS_INITIALIZED sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-DIMENSION sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-DIMENSION_DESC sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-FACTOR_NAME sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-UNIT_DESC sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-SAMP_TYPE_DESC sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-LOC_ROOT_NAME_REF sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-EEW_DTS_ROOT_DT sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-HAZARD sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-JOB_DESC sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-AGENT_DESC sy-vline
WA_EHFNDS_DTS_ROOT_DT_STR-AGENT_COMBINED_KEY_REF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.