ABAP Select data from SAP table EHFNDS_API_PPM_HAND into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDS_API_PPM_HAND table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDS_API_PPM_HAND. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDS_API_PPM_HAND table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDS_API_PPM_HAND TYPE STANDARD TABLE OF EHFNDS_API_PPM_HAND,
      WA_EHFNDS_API_PPM_HAND TYPE EHFNDS_API_PPM_HAND,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDS_API_PPM_HAND> TYPE EHFNDS_API_PPM_HAND.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDS_API_PPM_HAND.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDS_API_PPM_HAND
  INTO TABLE IT_EHFNDS_API_PPM_HAND.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDS_API_PPM_HAND
*  INTO TABLE @DATA(IT_EHFNDS_API_PPM_HAND2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDS_API_PPM_HAND INDEX 1 INTO DATA(WA_EHFNDS_API_PPM_HAND2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDS_API_PPM_HAND ASSIGNING <EHFNDS_API_PPM_HAND>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDS_API_PPM_HAND>-KEY = 1.
<EHFNDS_API_PPM_HAND>-PARENT_KEY = 1.
<EHFNDS_API_PPM_HAND>-ROOT_KEY = 1.
<EHFNDS_API_PPM_HAND>-PCPRPTYSEQUENCE = 1.
<EHFNDS_API_PPM_HAND>-PRSNLPROTGLOVEMATERIALTYPEUUID = 1.
ENDLOOP.

LOOP AT IT_EHFNDS_API_PPM_HAND INTO WA_EHFNDS_API_PPM_HAND.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDS_API_PPM_HAND-PRSNLPROTGLOVEPROTINDEXUUID, sy-vline,
WA_EHFNDS_API_PPM_HAND-PRSNLPROTGLOVEADDLSTMNTUUID, sy-vline,
WA_EHFNDS_API_PPM_HAND-PRSNLPROTGLOVEMAXWEARDURN, sy-vline,
WA_EHFNDS_API_PPM_HAND-PRSNLPROTWEARDURNLOWRQTYOPTR, sy-vline,
WA_EHFNDS_API_PPM_HAND-PRSNLPROTGLOVEMAXWEARDURNTXT, sy-vline,
WA_EHFNDS_API_PPM_HAND-PRSNLPROTWEARDURNUPPERQTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDS_API_PPM_HAND you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDS_API_PPM_HAND TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDS_API_PPM_HAND INTO WA_EHFNDS_API_PPM_HAND. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDS_API_PPM_HAND_STR,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
PCPRPTYSEQUENCE TYPE STRING,
PRSNLPROTGLOVEMATERIALTYPEUUID TYPE STRING,
PRSNLPROTGLOVEPROTINDEXUUID TYPE STRING,
PRSNLPROTGLOVEADDLSTMNTUUID TYPE STRING,
PRSNLPROTGLOVEMAXWEARDURN TYPE STRING,
PRSNLPROTWEARDURNLOWRQTYOPTR TYPE STRING,
PRSNLPROTGLOVEMAXWEARDURNTXT TYPE STRING,
PRSNLPROTWEARDURNUPPERQTY TYPE STRING,
PRSNLPROTWEARDURNUPPERQTYOPTR TYPE STRING,
PRSNLPROTWEARDURNUPPERQTYTXT TYPE STRING,
PRSNLPROTGLOVEMAXWEARDURNUNIT TYPE STRING,
PRSNLPROTGLOVETHICKNESSQTY TYPE STRING,
PRSNLPROTTHICKNESSLOWRQTYOPTR TYPE STRING,
PRSNLPROTGLOVETHICKNESSQTYTXT TYPE STRING,
PRSNLPROTTHICKNESSUPPERQTY TYPE STRING,
PRSNLPROTTHICKNESSUPPERQTYOPTR TYPE STRING,
PRSNLPROTTHICKNESSUPPERQTYTXT TYPE STRING,
PRSNLPROTGLOVETHICKNESSUNIT TYPE STRING,
CREATIONDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
ISACTIVEENTITY TYPE STRING,
RATINGS TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDS_API_PPM_HAND_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDS_API_PPM_HAND_STR-KEY sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PARENT_KEY sy-vline
WA_EHFNDS_API_PPM_HAND_STR-ROOT_KEY sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PCPRPTYSEQUENCE sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTGLOVEMATERIALTYPEUUID sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTGLOVEPROTINDEXUUID sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTGLOVEADDLSTMNTUUID sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTGLOVEMAXWEARDURN sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTWEARDURNLOWRQTYOPTR sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTGLOVEMAXWEARDURNTXT sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTWEARDURNUPPERQTY sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTWEARDURNUPPERQTYOPTR sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTWEARDURNUPPERQTYTXT sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTGLOVEMAXWEARDURNUNIT sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTGLOVETHICKNESSQTY sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTTHICKNESSLOWRQTYOPTR sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTGLOVETHICKNESSQTYTXT sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTTHICKNESSUPPERQTY sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTTHICKNESSUPPERQTYOPTR sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTTHICKNESSUPPERQTYTXT sy-vline
WA_EHFNDS_API_PPM_HAND_STR-PRSNLPROTGLOVETHICKNESSUNIT sy-vline
WA_EHFNDS_API_PPM_HAND_STR-CREATIONDATETIME sy-vline
WA_EHFNDS_API_PPM_HAND_STR-CREATEDBYUSER sy-vline
WA_EHFNDS_API_PPM_HAND_STR-LASTCHANGEDATETIME sy-vline
WA_EHFNDS_API_PPM_HAND_STR-LASTCHANGEDBYUSER sy-vline
WA_EHFNDS_API_PPM_HAND_STR-ACTIVEUUID sy-vline
WA_EHFNDS_API_PPM_HAND_STR-HASACTIVEENTITY sy-vline
WA_EHFNDS_API_PPM_HAND_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_EHFNDS_API_PPM_HAND_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_EHFNDS_API_PPM_HAND_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_EHFNDS_API_PPM_HAND_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_EHFNDS_API_PPM_HAND_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_EHFNDS_API_PPM_HAND_STR-ISACTIVEENTITY sy-vline
WA_EHFNDS_API_PPM_HAND_STR-RATINGS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.