ABAP Select data from SAP table EHFNDD_CCW_WCAST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDD_CCW_WCAST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDD_CCW_WCAST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDD_CCW_WCAST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDD_CCW_WCAST TYPE STANDARD TABLE OF EHFNDD_CCW_WCAST,
      WA_EHFNDD_CCW_WCAST TYPE EHFNDD_CCW_WCAST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDD_CCW_WCAST> TYPE EHFNDD_CCW_WCAST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDD_CCW_WCAST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDD_CCW_WCAST
  INTO TABLE IT_EHFNDD_CCW_WCAST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDD_CCW_WCAST
*  INTO TABLE @DATA(IT_EHFNDD_CCW_WCAST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDD_CCW_WCAST INDEX 1 INTO DATA(WA_EHFNDD_CCW_WCAST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDD_CCW_WCAST ASSIGNING <EHFNDD_CCW_WCAST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDD_CCW_WCAST>-MANDT = 1.
<EHFNDD_CCW_WCAST>-UUID = 1.
<EHFNDD_CCW_WCAST>-CCW_WCODE_UUID = 1.
<EHFNDD_CCW_WCAST>-CREA_DATE_TIME = 1.
<EHFNDD_CCW_WCAST>-CREA_UNAME = 1.
ENDLOOP.

LOOP AT IT_EHFNDD_CCW_WCAST INTO WA_EHFNDD_CCW_WCAST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDD_CCW_WCAST-LCHG_DATE_TIME, sy-vline,
WA_EHFNDD_CCW_WCAST-LCHG_UNAME, sy-vline,
WA_EHFNDD_CCW_WCAST-WASTECODE_UUID, sy-vline,
WA_EHFNDD_CCW_WCAST-WASTE_CODE, sy-vline,
WA_EHFNDD_CCW_WCAST-WASTECODE_SEQ, sy-vline,
ENDLOOP. *Add any further fields from structure WA_EHFNDD_CCW_WCAST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDD_CCW_WCAST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDD_CCW_WCAST INTO WA_EHFNDD_CCW_WCAST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDD_CCW_WCAST_STR,
MANDT TYPE STRING,
UUID TYPE STRING,
CCW_WCODE_UUID TYPE STRING,
CREA_DATE_TIME TYPE STRING,
CREA_UNAME TYPE STRING,
LCHG_DATE_TIME TYPE STRING,
LCHG_UNAME TYPE STRING,
WASTECODE_UUID TYPE STRING,
WASTE_CODE TYPE STRING,
WASTECODE_SEQ TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDD_CCW_WCAST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDD_CCW_WCAST_STR-MANDT sy-vline
WA_EHFNDD_CCW_WCAST_STR-UUID sy-vline
WA_EHFNDD_CCW_WCAST_STR-CCW_WCODE_UUID sy-vline
WA_EHFNDD_CCW_WCAST_STR-CREA_DATE_TIME sy-vline
WA_EHFNDD_CCW_WCAST_STR-CREA_UNAME sy-vline
WA_EHFNDD_CCW_WCAST_STR-LCHG_DATE_TIME sy-vline
WA_EHFNDD_CCW_WCAST_STR-LCHG_UNAME sy-vline
WA_EHFNDD_CCW_WCAST_STR-WASTECODE_UUID sy-vline
WA_EHFNDD_CCW_WCAST_STR-WASTE_CODE sy-vline
WA_EHFNDD_CCW_WCAST_STR-WASTECODE_SEQ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.