ABAP Select data from SAP table EHFNDD_CCI_ED into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDD_CCI_ED table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDD_CCI_ED. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDD_CCI_ED table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDD_CCI_ED TYPE STANDARD TABLE OF EHFNDD_CCI_ED,
      WA_EHFNDD_CCI_ED TYPE EHFNDD_CCI_ED,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDD_CCI_ED> TYPE EHFNDD_CCI_ED.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDD_CCI_ED.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDD_CCI_ED
  INTO TABLE IT_EHFNDD_CCI_ED.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDD_CCI_ED
*  INTO TABLE @DATA(IT_EHFNDD_CCI_ED2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDD_CCI_ED INDEX 1 INTO DATA(WA_EHFNDD_CCI_ED2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDD_CCI_ED ASSIGNING <EHFNDD_CCI_ED>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDD_CCI_ED>-CLIENT = 1.
<EHFNDD_CCI_ED>-CHMLCMPLNCINFOUUID = 1.
<EHFNDD_CCI_ED>-DESCRIPTIONOFDNGRSGDSPCKG = 1.
<EHFNDD_CCI_ED>-DANGEROUSGOODSENCLOSUREQTY = 1.
<EHFNDD_CCI_ED>-DANGEROUSGOODSENCLOSUREUNIT = 1.
ENDLOOP.

LOOP AT IT_EHFNDD_CCI_ED INTO WA_EHFNDD_CCI_ED.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDD_CCI_ED-DESCOFDNGRSGDSINNERPACKGG, sy-vline,
WA_EHFNDD_CCI_ED-DNGRSGDSENCLRINNERPACKAGEQTY, sy-vline,
WA_EHFNDD_CCI_ED-DNGRSGDSENCLRINNERPACKAGEUNIT, sy-vline,
WA_EHFNDD_CCI_ED-DNGRSGDSENCLRNMBROFINNERPCKGS, sy-vline,
WA_EHFNDD_CCI_ED-DANGEROUSGOODSCONTROLTEMP, sy-vline,
WA_EHFNDD_CCI_ED-DANGEROUSGOODSCONTROLTEMPUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDD_CCI_ED you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDD_CCI_ED TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDD_CCI_ED INTO WA_EHFNDD_CCI_ED. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field DANGEROUSGOODSENCLOSUREUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDD_CCI_ED-DANGEROUSGOODSENCLOSUREUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDD_CCI_ED-DANGEROUSGOODSENCLOSUREUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DNGRSGDSENCLRINNERPACKAGEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDD_CCI_ED-DNGRSGDSENCLRINNERPACKAGEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDD_CCI_ED-DNGRSGDSENCLRINNERPACKAGEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DANGEROUSGOODSCONTROLTEMPUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDD_CCI_ED-DANGEROUSGOODSCONTROLTEMPUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDD_CCI_ED-DANGEROUSGOODSCONTROLTEMPUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DANGEROUSGOODSEMGYTEMPUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDD_CCI_ED-DANGEROUSGOODSEMGYTEMPUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDD_CCI_ED-DANGEROUSGOODSEMGYTEMPUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDD_CCI_ED_STR,
CLIENT TYPE STRING,
CHMLCMPLNCINFOUUID TYPE STRING,
DESCRIPTIONOFDNGRSGDSPCKG TYPE STRING,
DANGEROUSGOODSENCLOSUREQTY TYPE STRING,
DANGEROUSGOODSENCLOSUREUNIT TYPE STRING,
DESCOFDNGRSGDSINNERPACKGG TYPE STRING,
DNGRSGDSENCLRINNERPACKAGEQTY TYPE STRING,
DNGRSGDSENCLRINNERPACKAGEUNIT TYPE STRING,
DNGRSGDSENCLRNMBROFINNERPCKGS TYPE STRING,
DANGEROUSGOODSCONTROLTEMP TYPE STRING,
DANGEROUSGOODSCONTROLTEMPUNIT TYPE STRING,
DANGEROUSGOODSEMERGENCYTEMP TYPE STRING,
DANGEROUSGOODSEMGYTEMPUNIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDD_CCI_ED_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDD_CCI_ED_STR-CLIENT sy-vline
WA_EHFNDD_CCI_ED_STR-CHMLCMPLNCINFOUUID sy-vline
WA_EHFNDD_CCI_ED_STR-DESCRIPTIONOFDNGRSGDSPCKG sy-vline
WA_EHFNDD_CCI_ED_STR-DANGEROUSGOODSENCLOSUREQTY sy-vline
WA_EHFNDD_CCI_ED_STR-DANGEROUSGOODSENCLOSUREUNIT sy-vline
WA_EHFNDD_CCI_ED_STR-DESCOFDNGRSGDSINNERPACKGG sy-vline
WA_EHFNDD_CCI_ED_STR-DNGRSGDSENCLRINNERPACKAGEQTY sy-vline
WA_EHFNDD_CCI_ED_STR-DNGRSGDSENCLRINNERPACKAGEUNIT sy-vline
WA_EHFNDD_CCI_ED_STR-DNGRSGDSENCLRNMBROFINNERPCKGS sy-vline
WA_EHFNDD_CCI_ED_STR-DANGEROUSGOODSCONTROLTEMP sy-vline
WA_EHFNDD_CCI_ED_STR-DANGEROUSGOODSCONTROLTEMPUNIT sy-vline
WA_EHFNDD_CCI_ED_STR-DANGEROUSGOODSEMERGENCYTEMP sy-vline
WA_EHFNDD_CCI_ED_STR-DANGEROUSGOODSEMGYTEMPUNIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.