ABAP Select data from SAP table EHDGMS_CLDD_MESSAGE_INT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHDGMS_CLDD_MESSAGE_INT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHDGMS_CLDD_MESSAGE_INT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHDGMS_CLDD_MESSAGE_INT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHDGMS_CLDD_MESSAGE_INT TYPE STANDARD TABLE OF EHDGMS_CLDD_MESSAGE_INT,
      WA_EHDGMS_CLDD_MESSAGE_INT TYPE EHDGMS_CLDD_MESSAGE_INT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHDGMS_CLDD_MESSAGE_INT> TYPE EHDGMS_CLDD_MESSAGE_INT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHDGMS_CLDD_MESSAGE_INT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHDGMS_CLDD_MESSAGE_INT
  INTO TABLE IT_EHDGMS_CLDD_MESSAGE_INT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHDGMS_CLDD_MESSAGE_INT
*  INTO TABLE @DATA(IT_EHDGMS_CLDD_MESSAGE_INT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHDGMS_CLDD_MESSAGE_INT INDEX 1 INTO DATA(WA_EHDGMS_CLDD_MESSAGE_INT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHDGMS_CLDD_MESSAGE_INT ASSIGNING <EHDGMS_CLDD_MESSAGE_INT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHDGMS_CLDD_MESSAGE_INT>-COMPL_REQ_ID = 1.
<EHDGMS_CLDD_MESSAGE_INT>-LANGUAGE = 1.
<EHDGMS_CLDD_MESSAGE_INT>-REGULATION = 1.
<EHDGMS_CLDD_MESSAGE_INT>-INTERNAL_LANGUAGE = 1.
<EHDGMS_CLDD_MESSAGE_INT>-MSGTY = 1.
ENDLOOP.

LOOP AT IT_EHDGMS_CLDD_MESSAGE_INT INTO WA_EHDGMS_CLDD_MESSAGE_INT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHDGMS_CLDD_MESSAGE_INT-MSGID, sy-vline,
WA_EHDGMS_CLDD_MESSAGE_INT-MSGNO, sy-vline,
WA_EHDGMS_CLDD_MESSAGE_INT-MSGV1, sy-vline,
WA_EHDGMS_CLDD_MESSAGE_INT-MSGV2, sy-vline,
WA_EHDGMS_CLDD_MESSAGE_INT-MSGV3, sy-vline,
WA_EHDGMS_CLDD_MESSAGE_INT-MSGV4, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHDGMS_CLDD_MESSAGE_INT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHDGMS_CLDD_MESSAGE_INT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHDGMS_CLDD_MESSAGE_INT INTO WA_EHDGMS_CLDD_MESSAGE_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EHDGMS_CLDD_MESSAGE_INT-LANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHDGMS_CLDD_MESSAGE_INT-LANGUAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field INTERNAL_LANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EHDGMS_CLDD_MESSAGE_INT-INTERNAL_LANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHDGMS_CLDD_MESSAGE_INT-INTERNAL_LANGUAGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHDGMS_CLDD_MESSAGE_INT_STR,
COMPL_REQ_ID TYPE STRING,
LANGUAGE TYPE STRING,
REGULATION TYPE STRING,
INTERNAL_LANGUAGE TYPE STRING,
MSGTY TYPE STRING,
MSGID TYPE STRING,
MSGNO TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,
MSGV1_SRC TYPE STRING,
MSGV2_SRC TYPE STRING,
MSGV3_SRC TYPE STRING,
MSGV4_SRC TYPE STRING,
DETLEVEL TYPE STRING,
PROBCLASS TYPE STRING,
ALSORT TYPE STRING,
TIME_STMP TYPE STRING,
MSG_COUNT TYPE STRING,
CONTEXT TYPE STRING,
TABNAME TYPE STRING,
VALUE TYPE STRING,
PARAMS TYPE STRING,
T_PAR TYPE STRING,
CALLBACK TYPE STRING,
USEREXITP TYPE STRING,
USEREXITF TYPE STRING,
USEREXITT TYPE STRING,
ALTEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHDGMS_CLDD_MESSAGE_INT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-COMPL_REQ_ID sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-LANGUAGE sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-REGULATION sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-INTERNAL_LANGUAGE sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGTY sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGID sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGNO sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGV1 sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGV2 sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGV3 sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGV4 sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGV1_SRC sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGV2_SRC sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGV3_SRC sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSGV4_SRC sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-DETLEVEL sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-PROBCLASS sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-ALSORT sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-TIME_STMP sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-MSG_COUNT sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-CONTEXT sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-TABNAME sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-VALUE sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-PARAMS sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-T_PAR sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-CALLBACK sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-USEREXITP sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-USEREXITF sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-USEREXITT sy-vline
WA_EHDGMS_CLDD_MESSAGE_INT_STR-ALTEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.