ABAP Select data from SAP table EHCSMS_SPC_REG_LIST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHCSMS_SPC_REG_LIST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHCSMS_SPC_REG_LIST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHCSMS_SPC_REG_LIST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHCSMS_SPC_REG_LIST TYPE STANDARD TABLE OF EHCSMS_SPC_REG_LIST,
      WA_EHCSMS_SPC_REG_LIST TYPE EHCSMS_SPC_REG_LIST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHCSMS_SPC_REG_LIST> TYPE EHCSMS_SPC_REG_LIST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHCSMS_SPC_REG_LIST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHCSMS_SPC_REG_LIST
  INTO TABLE IT_EHCSMS_SPC_REG_LIST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHCSMS_SPC_REG_LIST
*  INTO TABLE @DATA(IT_EHCSMS_SPC_REG_LIST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHCSMS_SPC_REG_LIST INDEX 1 INTO DATA(WA_EHCSMS_SPC_REG_LIST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHCSMS_SPC_REG_LIST ASSIGNING <EHCSMS_SPC_REG_LIST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHCSMS_SPC_REG_LIST>-MANDT = 1.
<EHCSMS_SPC_REG_LIST>-SLSTID = 1.
<EHCSMS_SPC_REG_LIST>-SLSTDIS = 1.
<EHCSMS_SPC_REG_LIST>-SLSTDAT = 1.
<EHCSMS_SPC_REG_LIST>-SLSTVER = 1.
ENDLOOP.

LOOP AT IT_EHCSMS_SPC_REG_LIST INTO WA_EHCSMS_SPC_REG_LIST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHCSMS_SPC_REG_LIST-SLSTRES, sy-vline,
WA_EHCSMS_SPC_REG_LIST-RVLID, sy-vline,
WA_EHCSMS_SPC_REG_LIST-REM, sy-vline,
WA_EHCSMS_SPC_REG_LIST-SLSTLAN, sy-vline,
WA_EHCSMS_SPC_REG_LIST-SLSTSID, sy-vline,
WA_EHCSMS_SPC_REG_LIST-SLSTSCH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHCSMS_SPC_REG_LIST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHCSMS_SPC_REG_LIST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHCSMS_SPC_REG_LIST INTO WA_EHCSMS_SPC_REG_LIST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SLSTRES CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHCSMS_SPC_REG_LIST-SLSTRES IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHCSMS_SPC_REG_LIST-SLSTRES.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EHCSMS_SPC_REG_LIST-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHCSMS_SPC_REG_LIST-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHCSMS_SPC_REG_LIST_STR,
MANDT TYPE STRING,
SLSTID TYPE STRING,
SLSTDIS TYPE STRING,
SLSTDAT TYPE STRING,
SLSTVER TYPE STRING,
SLSTRES TYPE STRING,
RVLID TYPE STRING,
REM TYPE STRING,
SLSTLAN TYPE STRING,
SLSTSID TYPE STRING,
SLSTSCH TYPE STRING,
NEGATIVFLG TYPE STRING,
LANGU TYPE STRING,
SLSTNAM TYPE STRING,
SLSTNA2 TYPE STRING,
SLSTCON TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHCSMS_SPC_REG_LIST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-MANDT sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTID sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTDIS sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTDAT sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTVER sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTRES sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-RVLID sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-REM sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTLAN sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTSID sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTSCH sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-NEGATIVFLG sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-LANGU sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTNAM sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTNA2 sy-vline
WA_EHCSMS_SPC_REG_LIST_STR-SLSTCON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.