ABAP Select data from SAP table EEDMSETTLINSELECT_INST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EEDMSETTLINSELECT_INST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EEDMSETTLINSELECT_INST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EEDMSETTLINSELECT_INST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EEDMSETTLINSELECT_INST TYPE STANDARD TABLE OF EEDMSETTLINSELECT_INST,
      WA_EEDMSETTLINSELECT_INST TYPE EEDMSETTLINSELECT_INST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EEDMSETTLINSELECT_INST> TYPE EEDMSETTLINSELECT_INST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EEDMSETTLINSELECT_INST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EEDMSETTLINSELECT_INST
  INTO TABLE IT_EEDMSETTLINSELECT_INST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EEDMSETTLINSELECT_INST
*  INTO TABLE @DATA(IT_EEDMSETTLINSELECT_INST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EEDMSETTLINSELECT_INST INDEX 1 INTO DATA(WA_EEDMSETTLINSELECT_INST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EEDMSETTLINSELECT_INST ASSIGNING <EEDMSETTLINSELECT_INST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EEDMSETTLINSELECT_INST>-SETTLUNIT = 1.
<EEDMSETTLINSELECT_INST>-ANLAGE = 1.
<EEDMSETTLINSELECT_INST>-INT_UI = 1.
<EEDMSETTLINSELECT_INST>-PROFROLE = 1.
<EEDMSETTLINSELECT_INST>-PROFILE = 1.
ENDLOOP.

LOOP AT IT_EEDMSETTLINSELECT_INST INTO WA_EEDMSETTLINSELECT_INST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EEDMSETTLINSELECT_INST-DATEFROM_A, sy-vline,
WA_EEDMSETTLINSELECT_INST-TIMEFROM_A, sy-vline,
WA_EEDMSETTLINSELECT_INST-DATETO_A, sy-vline,
WA_EEDMSETTLINSELECT_INST-TIMETO_A, sy-vline,
WA_EEDMSETTLINSELECT_INST-AB_S, sy-vline,
WA_EEDMSETTLINSELECT_INST-BIS_S, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EEDMSETTLINSELECT_INST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EEDMSETTLINSELECT_INST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EEDMSETTLINSELECT_INST INTO WA_EEDMSETTLINSELECT_INST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ANLAGE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EEDMSETTLINSELECT_INST-ANLAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EEDMSETTLINSELECT_INST-ANLAGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EEDMSETTLINSELECT_INST_STR,
SETTLUNIT TYPE STRING,
ANLAGE TYPE STRING,
INT_UI TYPE STRING,
PROFROLE TYPE STRING,
PROFILE TYPE STRING,
DATEFROM_A TYPE STRING,
TIMEFROM_A TYPE STRING,
DATETO_A TYPE STRING,
TIMETO_A TYPE STRING,
AB_S TYPE STRING,
BIS_S TYPE STRING,
DATEFROM_I TYPE STRING,
TIMEFROM_I TYPE STRING,
DATETO_I TYPE STRING,
TIMETO_I TYPE STRING,
AB_B TYPE STRING,
BIS_B TYPE STRING,
GRID_ID TYPE STRING,
DATEFROM_G TYPE STRING,
TIMEFROM_G TYPE STRING,
DATETO_G TYPE STRING,
TIMETO_G TYPE STRING,
SERVICE TYPE STRING,END OF T_EKKO_STR. DATA: WA_EEDMSETTLINSELECT_INST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EEDMSETTLINSELECT_INST_STR-SETTLUNIT sy-vline
WA_EEDMSETTLINSELECT_INST_STR-ANLAGE sy-vline
WA_EEDMSETTLINSELECT_INST_STR-INT_UI sy-vline
WA_EEDMSETTLINSELECT_INST_STR-PROFROLE sy-vline
WA_EEDMSETTLINSELECT_INST_STR-PROFILE sy-vline
WA_EEDMSETTLINSELECT_INST_STR-DATEFROM_A sy-vline
WA_EEDMSETTLINSELECT_INST_STR-TIMEFROM_A sy-vline
WA_EEDMSETTLINSELECT_INST_STR-DATETO_A sy-vline
WA_EEDMSETTLINSELECT_INST_STR-TIMETO_A sy-vline
WA_EEDMSETTLINSELECT_INST_STR-AB_S sy-vline
WA_EEDMSETTLINSELECT_INST_STR-BIS_S sy-vline
WA_EEDMSETTLINSELECT_INST_STR-DATEFROM_I sy-vline
WA_EEDMSETTLINSELECT_INST_STR-TIMEFROM_I sy-vline
WA_EEDMSETTLINSELECT_INST_STR-DATETO_I sy-vline
WA_EEDMSETTLINSELECT_INST_STR-TIMETO_I sy-vline
WA_EEDMSETTLINSELECT_INST_STR-AB_B sy-vline
WA_EEDMSETTLINSELECT_INST_STR-BIS_B sy-vline
WA_EEDMSETTLINSELECT_INST_STR-GRID_ID sy-vline
WA_EEDMSETTLINSELECT_INST_STR-DATEFROM_G sy-vline
WA_EEDMSETTLINSELECT_INST_STR-TIMEFROM_G sy-vline
WA_EEDMSETTLINSELECT_INST_STR-DATETO_G sy-vline
WA_EEDMSETTLINSELECT_INST_STR-TIMETO_G sy-vline
WA_EEDMSETTLINSELECT_INST_STR-SERVICE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.