ABAP Select data from SAP table EDOC_BR_NFE400NFE_VEIC_PROD into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EDOC_BR_NFE400NFE_VEIC_PROD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EDOC_BR_NFE400NFE_VEIC_PROD. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EDOC_BR_NFE400NFE_VEIC_PROD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EDOC_BR_NFE400NFE_VEIC_PROD TYPE STANDARD TABLE OF EDOC_BR_NFE400NFE_VEIC_PROD, WA_EDOC_BR_NFE400NFE_VEIC_PROD TYPE EDOC_BR_NFE400NFE_VEIC_PROD, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EDOC_BR_NFE400NFE_VEIC_PROD> TYPE EDOC_BR_NFE400NFE_VEIC_PROD. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EDOC_BR_NFE400NFE_VEIC_PROD. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EDOC_BR_NFE400NFE_VEIC_PROD INTO TABLE IT_EDOC_BR_NFE400NFE_VEIC_PROD. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EDOC_BR_NFE400NFE_VEIC_PROD * INTO TABLE @DATA(IT_EDOC_BR_NFE400NFE_VEIC_PROD2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EDOC_BR_NFE400NFE_VEIC_PROD INDEX 1 INTO DATA(WA_EDOC_BR_NFE400NFE_VEIC_PROD2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EDOC_BR_NFE400NFE_VEIC_PROD ASSIGNING <EDOC_BR_NFE400NFE_VEIC_PROD>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EDOC_BR_NFE400NFE_VEIC_PROD>-TPOP = 1.
<EDOC_BR_NFE400NFE_VEIC_PROD>-CHASSI = 1.
<EDOC_BR_NFE400NFE_VEIC_PROD>-CCOR = 1.
<EDOC_BR_NFE400NFE_VEIC_PROD>-XCOR = 1.
<EDOC_BR_NFE400NFE_VEIC_PROD>-POT = 1.
ENDLOOP. LOOP AT IT_EDOC_BR_NFE400NFE_VEIC_PROD INTO WA_EDOC_BR_NFE400NFE_VEIC_PROD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EDOC_BR_NFE400NFE_VEIC_PROD-CILIN, sy-vline,
WA_EDOC_BR_NFE400NFE_VEIC_PROD-PESOL, sy-vline,
WA_EDOC_BR_NFE400NFE_VEIC_PROD-PESOB, sy-vline,
WA_EDOC_BR_NFE400NFE_VEIC_PROD-NSERIE, sy-vline,
WA_EDOC_BR_NFE400NFE_VEIC_PROD-TPCOMB, sy-vline,
WA_EDOC_BR_NFE400NFE_VEIC_PROD-NMOTOR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EDOC_BR_NFE400NFE_VEIC_PROD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EDOC_BR_NFE400NFE_VEIC_PROD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EDOC_BR_NFE400NFE_VEIC_PROD INTO WA_EDOC_BR_NFE400NFE_VEIC_PROD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EDOC_BR_NFE400NFE_VEIC_PROD_STR,
TPOP TYPE STRING,
CHASSI TYPE STRING,
CCOR TYPE STRING,
XCOR TYPE STRING,
POT TYPE STRING,
CILIN TYPE STRING,
PESOL TYPE STRING,
PESOB TYPE STRING,
NSERIE TYPE STRING,
TPCOMB TYPE STRING,
NMOTOR TYPE STRING,
CMT TYPE STRING,
DIST TYPE STRING,
ANOMOD TYPE STRING,
ANOFAB TYPE STRING,
TPPINT TYPE STRING,
TPVEIC TYPE STRING,
ESPVEIC TYPE STRING,
VIN TYPE STRING,
CONDVEIC TYPE STRING,
CMOD TYPE STRING,
CCORDENATRAN TYPE STRING,
LOTA TYPE STRING,
TPREST TYPE STRING,END OF T_EKKO_STR. DATA: WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-TPOP sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-CHASSI sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-CCOR sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-XCOR sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-POT sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-CILIN sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-PESOL sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-PESOB sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-NSERIE sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-TPCOMB sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-NMOTOR sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-CMT sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-DIST sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-ANOMOD sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-ANOFAB sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-TPPINT sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-TPVEIC sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-ESPVEIC sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-VIN sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-CONDVEIC sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-CMOD sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-CCORDENATRAN sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-LOTA sy-vline
WA_EDOC_BR_NFE400NFE_VEIC_PROD_STR-TPREST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.