ABAP Select data from SAP table EDOC_BR_NFE400NFE_TOTAL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EDOC_BR_NFE400NFE_TOTAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EDOC_BR_NFE400NFE_TOTAL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EDOC_BR_NFE400NFE_TOTAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EDOC_BR_NFE400NFE_TOTAL TYPE STANDARD TABLE OF EDOC_BR_NFE400NFE_TOTAL,
      WA_EDOC_BR_NFE400NFE_TOTAL TYPE EDOC_BR_NFE400NFE_TOTAL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EDOC_BR_NFE400NFE_TOTAL> TYPE EDOC_BR_NFE400NFE_TOTAL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EDOC_BR_NFE400NFE_TOTAL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EDOC_BR_NFE400NFE_TOTAL
  INTO TABLE IT_EDOC_BR_NFE400NFE_TOTAL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EDOC_BR_NFE400NFE_TOTAL
*  INTO TABLE @DATA(IT_EDOC_BR_NFE400NFE_TOTAL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EDOC_BR_NFE400NFE_TOTAL INDEX 1 INTO DATA(WA_EDOC_BR_NFE400NFE_TOTAL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EDOC_BR_NFE400NFE_TOTAL ASSIGNING <EDOC_BR_NFE400NFE_TOTAL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EDOC_BR_NFE400NFE_TOTAL>-ICMSTOT = 1.
<EDOC_BR_NFE400NFE_TOTAL>-VBC = 1.
<EDOC_BR_NFE400NFE_TOTAL>-VICMS = 1.
<EDOC_BR_NFE400NFE_TOTAL>-VICMSDESON = 1.
<EDOC_BR_NFE400NFE_TOTAL>-VFCPUFDEST = 1.
ENDLOOP.

LOOP AT IT_EDOC_BR_NFE400NFE_TOTAL INTO WA_EDOC_BR_NFE400NFE_TOTAL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EDOC_BR_NFE400NFE_TOTAL-VICMSUFDEST, sy-vline,
WA_EDOC_BR_NFE400NFE_TOTAL-VICMSUFREMET, sy-vline,
WA_EDOC_BR_NFE400NFE_TOTAL-VFCP, sy-vline,
WA_EDOC_BR_NFE400NFE_TOTAL-VBCST, sy-vline,
WA_EDOC_BR_NFE400NFE_TOTAL-VST, sy-vline,
WA_EDOC_BR_NFE400NFE_TOTAL-VFCPST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EDOC_BR_NFE400NFE_TOTAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EDOC_BR_NFE400NFE_TOTAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EDOC_BR_NFE400NFE_TOTAL INTO WA_EDOC_BR_NFE400NFE_TOTAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EDOC_BR_NFE400NFE_TOTAL_STR,
ICMSTOT TYPE STRING,
VBC TYPE STRING,
VICMS TYPE STRING,
VICMSDESON TYPE STRING,
VFCPUFDEST TYPE STRING,
VICMSUFDEST TYPE STRING,
VICMSUFREMET TYPE STRING,
VFCP TYPE STRING,
VBCST TYPE STRING,
VST TYPE STRING,
VFCPST TYPE STRING,
VFCPSTRET TYPE STRING,
VPROD TYPE STRING,
VFRETE TYPE STRING,
VSEG TYPE STRING,
VDESC TYPE STRING,
VII TYPE STRING,
VIPI TYPE STRING,
VIPIDEVOL TYPE STRING,
VPIS TYPE STRING,
VCOFINS TYPE STRING,
VOUTRO TYPE STRING,
VNF TYPE STRING,
VTOTTRIB TYPE STRING,
ISSQNTOT TYPE STRING,
VSERV TYPE STRING,
VBC TYPE STRING,
VISS TYPE STRING,
VPIS TYPE STRING,
VCOFINS TYPE STRING,
DCOMPET TYPE STRING,
VDEDUCAO TYPE STRING,
VOUTRO TYPE STRING,
VDESCINCOND TYPE STRING,
VDESCCOND TYPE STRING,
VISSRET TYPE STRING,
CREGTRIB TYPE STRING,
RETTRIB TYPE STRING,
VRETPIS TYPE STRING,
VRETCOFINS TYPE STRING,
VRETCSLL TYPE STRING,
VBCIRRF TYPE STRING,
VIRRF TYPE STRING,
VBCRETPREV TYPE STRING,
VRETPREV TYPE STRING,END OF T_EKKO_STR. DATA: WA_EDOC_BR_NFE400NFE_TOTAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-ICMSTOT sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VBC sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VICMS sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VICMSDESON sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VFCPUFDEST sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VICMSUFDEST sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VICMSUFREMET sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VFCP sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VBCST sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VST sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VFCPST sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VFCPSTRET sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VPROD sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VFRETE sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VSEG sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VDESC sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VII sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VIPI sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VIPIDEVOL sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VPIS sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VCOFINS sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VOUTRO sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VNF sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VTOTTRIB sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-ISSQNTOT sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VSERV sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VBC sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VISS sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VPIS sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VCOFINS sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-DCOMPET sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VDEDUCAO sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VOUTRO sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VDESCINCOND sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VDESCCOND sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VISSRET sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-CREGTRIB sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-RETTRIB sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VRETPIS sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VRETCOFINS sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VRETCSLL sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VBCIRRF sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VIRRF sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VBCRETPREV sy-vline
WA_EDOC_BR_NFE400NFE_TOTAL_STR-VRETPREV sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.