ABAP Select data from SAP table EDOC_BR_NFE400NFE_ICMSSN201 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EDOC_BR_NFE400NFE_ICMSSN201 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EDOC_BR_NFE400NFE_ICMSSN201. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EDOC_BR_NFE400NFE_ICMSSN201 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EDOC_BR_NFE400NFE_ICMSSN201 TYPE STANDARD TABLE OF EDOC_BR_NFE400NFE_ICMSSN201,
      WA_EDOC_BR_NFE400NFE_ICMSSN201 TYPE EDOC_BR_NFE400NFE_ICMSSN201,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EDOC_BR_NFE400NFE_ICMSSN201> TYPE EDOC_BR_NFE400NFE_ICMSSN201.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EDOC_BR_NFE400NFE_ICMSSN201.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EDOC_BR_NFE400NFE_ICMSSN201
  INTO TABLE IT_EDOC_BR_NFE400NFE_ICMSSN201.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EDOC_BR_NFE400NFE_ICMSSN201
*  INTO TABLE @DATA(IT_EDOC_BR_NFE400NFE_ICMSSN2012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EDOC_BR_NFE400NFE_ICMSSN201 INDEX 1 INTO DATA(WA_EDOC_BR_NFE400NFE_ICMSSN2012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EDOC_BR_NFE400NFE_ICMSSN201 ASSIGNING <EDOC_BR_NFE400NFE_ICMSSN201>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EDOC_BR_NFE400NFE_ICMSSN201>-ORIG = 1.
<EDOC_BR_NFE400NFE_ICMSSN201>-CSOSN = 1.
<EDOC_BR_NFE400NFE_ICMSSN201>-MODBCST = 1.
<EDOC_BR_NFE400NFE_ICMSSN201>-PMVAST = 1.
<EDOC_BR_NFE400NFE_ICMSSN201>-PREDBCST = 1.
ENDLOOP.

LOOP AT IT_EDOC_BR_NFE400NFE_ICMSSN201 INTO WA_EDOC_BR_NFE400NFE_ICMSSN201.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EDOC_BR_NFE400NFE_ICMSSN201-VBCST, sy-vline,
WA_EDOC_BR_NFE400NFE_ICMSSN201-PICMSST, sy-vline,
WA_EDOC_BR_NFE400NFE_ICMSSN201-VICMSST, sy-vline,
WA_EDOC_BR_NFE400NFE_ICMSSN201-VBCFCPST, sy-vline,
WA_EDOC_BR_NFE400NFE_ICMSSN201-PFCPST, sy-vline,
WA_EDOC_BR_NFE400NFE_ICMSSN201-VFCPST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EDOC_BR_NFE400NFE_ICMSSN201 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EDOC_BR_NFE400NFE_ICMSSN201 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EDOC_BR_NFE400NFE_ICMSSN201 INTO WA_EDOC_BR_NFE400NFE_ICMSSN201. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EDOC_BR_NFE400NFE_ICMSSN201_STR,
ORIG TYPE STRING,
CSOSN TYPE STRING,
MODBCST TYPE STRING,
PMVAST TYPE STRING,
PREDBCST TYPE STRING,
VBCST TYPE STRING,
PICMSST TYPE STRING,
VICMSST TYPE STRING,
VBCFCPST TYPE STRING,
PFCPST TYPE STRING,
VFCPST TYPE STRING,
PCREDSN TYPE STRING,
VCREDICMSSN TYPE STRING,END OF T_EKKO_STR. DATA: WA_EDOC_BR_NFE400NFE_ICMSSN201_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-ORIG sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-CSOSN sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-MODBCST sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-PMVAST sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-PREDBCST sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-VBCST sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-PICMSST sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-VICMSST sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-VBCFCPST sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-PFCPST sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-VFCPST sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-PCREDSN sy-vline
WA_EDOC_BR_NFE400NFE_ICMSSN201_STR-VCREDICMSSN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.