ABAP Select data from SAP table EDO_TR_SCOPE_INFORMATION7 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EDO_TR_SCOPE_INFORMATION7 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EDO_TR_SCOPE_INFORMATION7. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EDO_TR_SCOPE_INFORMATION7 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EDO_TR_SCOPE_INFORMATION7 TYPE STANDARD TABLE OF EDO_TR_SCOPE_INFORMATION7, WA_EDO_TR_SCOPE_INFORMATION7 TYPE EDO_TR_SCOPE_INFORMATION7, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EDO_TR_SCOPE_INFORMATION7> TYPE EDO_TR_SCOPE_INFORMATION7. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EDO_TR_SCOPE_INFORMATION7. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EDO_TR_SCOPE_INFORMATION7 INTO TABLE IT_EDO_TR_SCOPE_INFORMATION7. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EDO_TR_SCOPE_INFORMATION7 * INTO TABLE @DATA(IT_EDO_TR_SCOPE_INFORMATION72). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EDO_TR_SCOPE_INFORMATION7 INDEX 1 INTO DATA(WA_EDO_TR_SCOPE_INFORMATION72). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EDO_TR_SCOPE_INFORMATION7 ASSIGNING <EDO_TR_SCOPE_INFORMATION7>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EDO_TR_SCOPE_INFORMATION7>-SELECTION = 1.
<EDO_TR_SCOPE_INFORMATION7>-CONTROLLER = 1.
<EDO_TR_SCOPE_INFORMATION7>-BUSINESS_SERVICE = 1.
<EDO_TR_SCOPE_INFORMATION7>-CONTROLLER = 1.
<EDO_TR_SCOPE_INFORMATION7>-BUSINESS_SERVICE_NAME = 1.
ENDLOOP. LOOP AT IT_EDO_TR_SCOPE_INFORMATION7 INTO WA_EDO_TR_SCOPE_INFORMATION7. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EDO_TR_SCOPE_INFORMATION7-SERVICE_TRANSACTION, sy-vline,
WA_EDO_TR_SCOPE_INFORMATION7-CONTROLLER, sy-vline,
WA_EDO_TR_SCOPE_INFORMATION7-TYPE_OF_SERVICE_TRANSACTION, sy-vline,
WA_EDO_TR_SCOPE_INFORMATION7-IS_NON_REPUDIATION_REQUIRED, sy-vline,
WA_EDO_TR_SCOPE_INFORMATION7-IS_AUTHENTICATION_REQUIRED, sy-vline,
WA_EDO_TR_SCOPE_INFORMATION7-IS_NON_REPUDIATION_OF_RECEIPT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EDO_TR_SCOPE_INFORMATION7 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EDO_TR_SCOPE_INFORMATION7 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EDO_TR_SCOPE_INFORMATION7 INTO WA_EDO_TR_SCOPE_INFORMATION7. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EDO_TR_SCOPE_INFORMATION7_STR,
SELECTION TYPE STRING,
CONTROLLER TYPE STRING,
BUSINESS_SERVICE TYPE STRING,
CONTROLLER TYPE STRING,
BUSINESS_SERVICE_NAME TYPE STRING,
SERVICE_TRANSACTION TYPE STRING,
CONTROLLER TYPE STRING,
TYPE_OF_SERVICE_TRANSACTION TYPE STRING,
IS_NON_REPUDIATION_REQUIRED TYPE STRING,
IS_AUTHENTICATION_REQUIRED TYPE STRING,
IS_NON_REPUDIATION_OF_RECEIPT TYPE STRING,
IS_INTELLIGIBLE_CHECK_REQUIRED TYPE STRING,
IS_APPLICATION_ERROR_RESPONSE TYPE STRING,
TIME_TO_ACKNOWLEDGE_RECEIPT TYPE STRING,
TIME_TO_ACKNOWLEDGE_ACCEPTANCE TYPE STRING,
TIME_TO_PERFORM TYPE STRING,
RECURRENCE TYPE STRING,
CORRELATION_INFORMATION TYPE STRING,
CONTROLLER TYPE STRING,
REQUESTING_DOCUMENT_CREATION_D TYPE STRING,
REQUESTING_DOCUMENT_INSTANCE_I TYPE STRING,
EXPECTED_RESPONSE_DATE_TIME TYPE STRING,
SCOPE_INFORMATION TYPE STRING,END OF T_EKKO_STR. DATA: WA_EDO_TR_SCOPE_INFORMATION7_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-SELECTION sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-CONTROLLER sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-BUSINESS_SERVICE sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-CONTROLLER sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-BUSINESS_SERVICE_NAME sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-SERVICE_TRANSACTION sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-CONTROLLER sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-TYPE_OF_SERVICE_TRANSACTION sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-IS_NON_REPUDIATION_REQUIRED sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-IS_AUTHENTICATION_REQUIRED sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-IS_NON_REPUDIATION_OF_RECEIPT sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-IS_INTELLIGIBLE_CHECK_REQUIRED sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-IS_APPLICATION_ERROR_RESPONSE sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-TIME_TO_ACKNOWLEDGE_RECEIPT sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-TIME_TO_ACKNOWLEDGE_ACCEPTANCE sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-TIME_TO_PERFORM sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-RECURRENCE sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-CORRELATION_INFORMATION sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-CONTROLLER sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-REQUESTING_DOCUMENT_CREATION_D sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-REQUESTING_DOCUMENT_INSTANCE_I sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-EXPECTED_RESPONSE_DATE_TIME sy-vline
WA_EDO_TR_SCOPE_INFORMATION7_STR-SCOPE_INFORMATION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.