ABAP Select data from SAP table EDO_ESSII_EX_TIPO_SIN_DESGLOSE into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EDO_ESSII_EX_TIPO_SIN_DESGLOSE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EDO_ESSII_EX_TIPO_SIN_DESGLOSE. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EDO_ESSII_EX_TIPO_SIN_DESGLOSE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EDO_ESSII_EX_TIPO_SIN_DESGLOSE TYPE STANDARD TABLE OF EDO_ESSII_EX_TIPO_SIN_DESGLOSE, WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE TYPE EDO_ESSII_EX_TIPO_SIN_DESGLOSE, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EDO_ESSII_EX_TIPO_SIN_DESGLOSE> TYPE EDO_ESSII_EX_TIPO_SIN_DESGLOSE. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EDO_ESSII_EX_TIPO_SIN_DESGLOSE. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EDO_ESSII_EX_TIPO_SIN_DESGLOSE INTO TABLE IT_EDO_ESSII_EX_TIPO_SIN_DESGLOSE. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EDO_ESSII_EX_TIPO_SIN_DESGLOSE * INTO TABLE @DATA(IT_EDO_ESSII_EX_TIPO_SIN_DESGLOSE2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EDO_ESSII_EX_TIPO_SIN_DESGLOSE INDEX 1 INTO DATA(WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EDO_ESSII_EX_TIPO_SIN_DESGLOSE ASSIGNING <EDO_ESSII_EX_TIPO_SIN_DESGLOSE>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EDO_ESSII_EX_TIPO_SIN_DESGLOSE>-CONTROLLER = 1.
<EDO_ESSII_EX_TIPO_SIN_DESGLOSE>-SUJETA = 1.
<EDO_ESSII_EX_TIPO_SIN_DESGLOSE>-CONTROLLER = 1.
<EDO_ESSII_EX_TIPO_SIN_DESGLOSE>-EXENTA = 1.
<EDO_ESSII_EX_TIPO_SIN_DESGLOSE>-CONTROLLER = 1.
ENDLOOP. LOOP AT IT_EDO_ESSII_EX_TIPO_SIN_DESGLOSE INTO WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE-DETALLE_EXENTA, sy-vline,
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE-NO_EXENTA, sy-vline,
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE-CONTROLLER, sy-vline,
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE-TIPO_NO_EXENTA, sy-vline,
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE-DESGLOSE_IVA, sy-vline,
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE-CONTROLLER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EDO_ESSII_EX_TIPO_SIN_DESGLOSE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EDO_ESSII_EX_TIPO_SIN_DESGLOSE INTO WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR,
CONTROLLER TYPE STRING,
SUJETA TYPE STRING,
CONTROLLER TYPE STRING,
EXENTA TYPE STRING,
CONTROLLER TYPE STRING,
DETALLE_EXENTA TYPE STRING,
NO_EXENTA TYPE STRING,
CONTROLLER TYPE STRING,
TIPO_NO_EXENTA TYPE STRING,
DESGLOSE_IVA TYPE STRING,
CONTROLLER TYPE STRING,
DETALLE_IVA TYPE STRING,
NO_SUJETA TYPE STRING,
CONTROLLER TYPE STRING,
IMPORTE_POR_ARTICULOS7_14_OTRO TYPE STRING,
IMPORTE_TAIREGLAS_LOCALIZACION TYPE STRING,END OF T_EKKO_STR. DATA: WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-CONTROLLER sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-SUJETA sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-CONTROLLER sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-EXENTA sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-CONTROLLER sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-DETALLE_EXENTA sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-NO_EXENTA sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-CONTROLLER sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-TIPO_NO_EXENTA sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-DESGLOSE_IVA sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-CONTROLLER sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-DETALLE_IVA sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-NO_SUJETA sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-CONTROLLER sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-IMPORTE_POR_ARTICULOS7_14_OTRO sy-vline
WA_EDO_ESSII_EX_TIPO_SIN_DESGLOSE_STR-IMPORTE_TAIREGLAS_LOCALIZACION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.