ABAP Select data from SAP table EDEX_REQMD_GRID_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EDEX_REQMD_GRID_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EDEX_REQMD_GRID_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EDEX_REQMD_GRID_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EDEX_REQMD_GRID_DATA TYPE STANDARD TABLE OF EDEX_REQMD_GRID_DATA,
WA_EDEX_REQMD_GRID_DATA TYPE EDEX_REQMD_GRID_DATA,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EDEX_REQMD_GRID_DATA> TYPE EDEX_REQMD_GRID_DATA.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_EDEX_REQMD_GRID_DATA.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM EDEX_REQMD_GRID_DATA
INTO TABLE IT_EDEX_REQMD_GRID_DATA.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM EDEX_REQMD_GRID_DATA
* INTO TABLE @DATA(IT_EDEX_REQMD_GRID_DATA2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EDEX_REQMD_GRID_DATA INDEX 1 INTO DATA(WA_EDEX_REQMD_GRID_DATA2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EDEX_REQMD_GRID_DATA ASSIGNING <EDEX_REQMD_GRID_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<EDEX_REQMD_GRID_DATA>-EUIGRID = 1.
<EDEX_REQMD_GRID_DATA>-MANDT = 1.
<EDEX_REQMD_GRID_DATA>-INT_UI = 1.
<EDEX_REQMD_GRID_DATA>-DATETO = 1.
<EDEX_REQMD_GRID_DATA>-TIMETO = 1.
ENDLOOP. LOOP AT IT_EDEX_REQMD_GRID_DATA INTO WA_EDEX_REQMD_GRID_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EDEX_REQMD_GRID_DATA-DATEFROM, sy-vline,
WA_EDEX_REQMD_GRID_DATA-TIMEFROM, sy-vline,
WA_EDEX_REQMD_GRID_DATA-GRID_ID, sy-vline,
WA_EDEX_REQMD_GRID_DATA-ERDAT, sy-vline,
WA_EDEX_REQMD_GRID_DATA-ERNAM, sy-vline,
WA_EDEX_REQMD_GRID_DATA-AEDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EDEX_REQMD_GRID_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EDEX_REQMD_GRID_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EDEX_REQMD_GRID_DATA INTO WA_EDEX_REQMD_GRID_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EDEX_REQMD_GRID_DATA-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EDEX_REQMD_GRID_DATA-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EDEX_REQMD_GRID_DATA_STR,
EUIGRID TYPE STRING,
MANDT TYPE STRING,
INT_UI TYPE STRING,
DATETO TYPE STRING,
TIMETO TYPE STRING,
DATEFROM TYPE STRING,
TIMEFROM TYPE STRING,
GRID_ID TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
BEGRU TYPE STRING,
LOEVM TYPE STRING,
GRID_LEVEL TYPE STRING,
EGRID TYPE STRING,
MANDT TYPE STRING,
GRID_ID TYPE STRING,
SUP_GRID_ID TYPE STRING,
SPARTYP TYPE STRING,
GRID_LEVEL_TYPE TYPE STRING,
EXTERNALID TYPE STRING,
EXT_CODELISTID TYPE STRING,
EGRIDT TYPE STRING,
MANDT TYPE STRING,
SPRAS TYPE STRING,
GRID_ID TYPE STRING,
GRID_NAME TYPE STRING,
IEEANL TYPE STRING,END OF T_EKKO_STR. DATA: WA_EDEX_REQMD_GRID_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-EUIGRID sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-MANDT sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-INT_UI sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-DATETO sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-TIMETO sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-DATEFROM sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-TIMEFROM sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-GRID_ID sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-ERDAT sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-ERNAM sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-AEDAT sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-AENAM sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-BEGRU sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-LOEVM sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-GRID_LEVEL sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-EGRID sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-MANDT sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-GRID_ID sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-SUP_GRID_ID sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-SPARTYP sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-GRID_LEVEL_TYPE sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-EXTERNALID sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-EXT_CODELISTID sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-EGRIDT sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-MANDT sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-SPRAS sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-GRID_ID sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-GRID_NAME sy-vline
WA_EDEX_REQMD_GRID_DATA_STR-IEEANL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.
