ABAP Select data from SAP table EDCONT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EDCONT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EDCONT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EDCONT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EDCONT TYPE STANDARD TABLE OF EDCONT,
      WA_EDCONT TYPE EDCONT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EDCONT> TYPE EDCONT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EDCONT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EDCONT
  INTO TABLE IT_EDCONT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EDCONT
*  INTO TABLE @DATA(IT_EDCONT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EDCONT INDEX 1 INTO DATA(WA_EDCONT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EDCONT ASSIGNING <EDCONT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EDCONT>-EDIT = 1.
<EDCONT>-APP_OPEN = 1.
<EDCONT>-APP_ID = 1.
<EDCONT>-APP_FUNC = 1.
<EDCONT>-APP_PARAM = 1.
ENDLOOP.

LOOP AT IT_EDCONT INTO WA_EDCONT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EDCONT-APP_MSG, sy-vline,
WA_EDCONT-APP_DISP, sy-vline,
WA_EDCONT-APP_OBJ, sy-vline,
WA_EDCONT-APP_ABAP, sy-vline,
WA_EDCONT-BUF_NEW, sy-vline,
WA_EDCONT-BUF_NAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EDCONT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EDCONT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EDCONT INTO WA_EDCONT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EDCONT_STR,
EDIT TYPE STRING,
APP_OPEN TYPE STRING,
APP_ID TYPE STRING,
APP_FUNC TYPE STRING,
APP_PARAM TYPE STRING,
APP_MSG TYPE STRING,
APP_DISP TYPE STRING,
APP_OBJ TYPE STRING,
APP_ABAP TYPE STRING,
BUF_NEW TYPE STRING,
BUF_NAME TYPE STRING,
FB_NAME TYPE STRING,
BUF_NUM TYPE STRING,
BUF_VARIED TYPE STRING,
BUF_CUNEW TYPE STRING,
BUF_CULINE TYPE STRING,
BUF_SCLINE TYPE STRING,
BUF_CUOFFS TYPE STRING,
BUF_CUWORD TYPE STRING,
BUF_CUSTRG TYPE STRING,
LINE_SIZE TYPE STRING,
SCR_NULL TYPE STRING,
LINE TYPE STRING,
TITLE TYPE STRING,
APP_PROG TYPE STRING,
INCLS_ENQD TYPE STRING,
EXTEND_MOD TYPE STRING,
STATUS_FLG TYPE STRING,
SAVED TYPE STRING,
TEXTTYPE TYPE STRING,
CONTENT TYPE STRING,
TITLE TYPE STRING,
CB_PROG TYPE STRING,
CB_PFKEY TYPE STRING,
CB_CHECK TYPE STRING,
CB_SAVE TYPE STRING,
CB_USERCOM TYPE STRING,END OF T_EKKO_STR. DATA: WA_EDCONT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EDCONT_STR-EDIT sy-vline
WA_EDCONT_STR-APP_OPEN sy-vline
WA_EDCONT_STR-APP_ID sy-vline
WA_EDCONT_STR-APP_FUNC sy-vline
WA_EDCONT_STR-APP_PARAM sy-vline
WA_EDCONT_STR-APP_MSG sy-vline
WA_EDCONT_STR-APP_DISP sy-vline
WA_EDCONT_STR-APP_OBJ sy-vline
WA_EDCONT_STR-APP_ABAP sy-vline
WA_EDCONT_STR-BUF_NEW sy-vline
WA_EDCONT_STR-BUF_NAME sy-vline
WA_EDCONT_STR-FB_NAME sy-vline
WA_EDCONT_STR-BUF_NUM sy-vline
WA_EDCONT_STR-BUF_VARIED sy-vline
WA_EDCONT_STR-BUF_CUNEW sy-vline
WA_EDCONT_STR-BUF_CULINE sy-vline
WA_EDCONT_STR-BUF_SCLINE sy-vline
WA_EDCONT_STR-BUF_CUOFFS sy-vline
WA_EDCONT_STR-BUF_CUWORD sy-vline
WA_EDCONT_STR-BUF_CUSTRG sy-vline
WA_EDCONT_STR-LINE_SIZE sy-vline
WA_EDCONT_STR-SCR_NULL sy-vline
WA_EDCONT_STR-LINE sy-vline
WA_EDCONT_STR-TITLE sy-vline
WA_EDCONT_STR-APP_PROG sy-vline
WA_EDCONT_STR-INCLS_ENQD sy-vline
WA_EDCONT_STR-EXTEND_MOD sy-vline
WA_EDCONT_STR-STATUS_FLG sy-vline
WA_EDCONT_STR-SAVED sy-vline
WA_EDCONT_STR-TEXTTYPE sy-vline
WA_EDCONT_STR-CONTENT sy-vline
WA_EDCONT_STR-TITLE sy-vline
WA_EDCONT_STR-CB_PROG sy-vline
WA_EDCONT_STR-CB_PFKEY sy-vline
WA_EDCONT_STR-CB_CHECK sy-vline
WA_EDCONT_STR-CB_SAVE sy-vline
WA_EDCONT_STR-CB_USERCOM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.