ABAP Select data from SAP table ECSTAT_S_AUGMENT_CHAR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ECSTAT_S_AUGMENT_CHAR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ECSTAT_S_AUGMENT_CHAR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ECSTAT_S_AUGMENT_CHAR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ECSTAT_S_AUGMENT_CHAR TYPE STANDARD TABLE OF ECSTAT_S_AUGMENT_CHAR,
      WA_ECSTAT_S_AUGMENT_CHAR TYPE ECSTAT_S_AUGMENT_CHAR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ECSTAT_S_AUGMENT_CHAR> TYPE ECSTAT_S_AUGMENT_CHAR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ECSTAT_S_AUGMENT_CHAR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ECSTAT_S_AUGMENT_CHAR
  INTO TABLE IT_ECSTAT_S_AUGMENT_CHAR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ECSTAT_S_AUGMENT_CHAR
*  INTO TABLE @DATA(IT_ECSTAT_S_AUGMENT_CHAR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ECSTAT_S_AUGMENT_CHAR INDEX 1 INTO DATA(WA_ECSTAT_S_AUGMENT_CHAR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ECSTAT_S_AUGMENT_CHAR ASSIGNING <ECSTAT_S_AUGMENT_CHAR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ECSTAT_S_AUGMENT_CHAR>-IDENTIFIER = 1.
<ECSTAT_S_AUGMENT_CHAR>-STARTPROF = 1.
<ECSTAT_S_AUGMENT_CHAR>-TESTSCRIPT = 1.
<ECSTAT_S_AUGMENT_CHAR>-TESTSCRIPT_VER = 1.
<ECSTAT_S_AUGMENT_CHAR>-START_TESTSCRIPT = 1.
ENDLOOP.

LOOP AT IT_ECSTAT_S_AUGMENT_CHAR INTO WA_ECSTAT_S_AUGMENT_CHAR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ECSTAT_S_AUGMENT_CHAR-START_TESTSCRIPT_VER, sy-vline,
WA_ECSTAT_S_AUGMENT_CHAR-R_START_TESTSCRIPT, sy-vline,
WA_ECSTAT_S_AUGMENT_CHAR-R_START_TESTSCRIPT_VER, sy-vline,
WA_ECSTAT_S_AUGMENT_CHAR-TESTCONF, sy-vline,
WA_ECSTAT_S_AUGMENT_CHAR-TESTCONF_VAR, sy-vline,
WA_ECSTAT_S_AUGMENT_CHAR-START_TESTCONF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ECSTAT_S_AUGMENT_CHAR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ECSTAT_S_AUGMENT_CHAR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ECSTAT_S_AUGMENT_CHAR INTO WA_ECSTAT_S_AUGMENT_CHAR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ECSTAT_S_AUGMENT_CHAR_STR,
IDENTIFIER TYPE STRING,
STARTPROF TYPE STRING,
TESTSCRIPT TYPE STRING,
TESTSCRIPT_VER TYPE STRING,
START_TESTSCRIPT TYPE STRING,
START_TESTSCRIPT_VER TYPE STRING,
R_START_TESTSCRIPT TYPE STRING,
R_START_TESTSCRIPT_VER TYPE STRING,
TESTCONF TYPE STRING,
TESTCONF_VAR TYPE STRING,
START_TESTCONF TYPE STRING,
START_TESTCONF_VAR TYPE STRING,
R_START_TESTCONF TYPE STRING,
R_START_TESTCONF_VAR TYPE STRING,
TESTCONT TYPE STRING,
TESTCONT_VAR TYPE STRING,
TESTCONT_VER TYPE STRING,
SYSTCONT TYPE STRING,
TARGSYST TYPE STRING,
LOC TYPE STRING,
LOC_SPACE TYPE STRING,
LOC_COMM TYPE STRING,
LOC_PROG TYPE STRING,END OF T_EKKO_STR. DATA: WA_ECSTAT_S_AUGMENT_CHAR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-IDENTIFIER sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-STARTPROF sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-TESTSCRIPT sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-TESTSCRIPT_VER sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-START_TESTSCRIPT sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-START_TESTSCRIPT_VER sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-R_START_TESTSCRIPT sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-R_START_TESTSCRIPT_VER sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-TESTCONF sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-TESTCONF_VAR sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-START_TESTCONF sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-START_TESTCONF_VAR sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-R_START_TESTCONF sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-R_START_TESTCONF_VAR sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-TESTCONT sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-TESTCONT_VAR sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-TESTCONT_VER sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-SYSTCONT sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-TARGSYST sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-LOC sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-LOC_SPACE sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-LOC_COMM sy-vline
WA_ECSTAT_S_AUGMENT_CHAR_STR-LOC_PROG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.