ABAP Select data from SAP table ECAMIOPR_COMPL_AU into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ECAMIOPR_COMPL_AU table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ECAMIOPR_COMPL_AU. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ECAMIOPR_COMPL_AU table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ECAMIOPR_COMPL_AU TYPE STANDARD TABLE OF ECAMIOPR_COMPL_AU,
      WA_ECAMIOPR_COMPL_AU TYPE ECAMIOPR_COMPL_AU,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ECAMIOPR_COMPL_AU> TYPE ECAMIOPR_COMPL_AU.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ECAMIOPR_COMPL_AU.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ECAMIOPR_COMPL_AU
  INTO TABLE IT_ECAMIOPR_COMPL_AU.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ECAMIOPR_COMPL_AU
*  INTO TABLE @DATA(IT_ECAMIOPR_COMPL_AU2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ECAMIOPR_COMPL_AU INDEX 1 INTO DATA(WA_ECAMIOPR_COMPL_AU2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ECAMIOPR_COMPL_AU ASSIGNING <ECAMIOPR_COMPL_AU>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ECAMIOPR_COMPL_AU>-BUPA_COMPL = 1.
<ECAMIOPR_COMPL_AU>-ACC = 1.
<ECAMIOPR_COMPL_AU>-CONT = 1.
<ECAMIOPR_COMPL_AU>-CI = 1.
<ECAMIOPR_COMPL_AU>-MR = 1.
ENDLOOP.

LOOP AT IT_ECAMIOPR_COMPL_AU INTO WA_ECAMIOPR_COMPL_AU.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ECAMIOPR_COMPL_AU-GEN, sy-vline,
WA_ECAMIOPR_COMPL_AU-LOCKED, sy-vline,
WA_ECAMIOPR_COMPL_AU-PRGUID, sy-vline,
WA_ECAMIOPR_COMPL_AU-XUCES, sy-vline,
WA_ECAMIOPR_COMPL_AU-MO, sy-vline,
WA_ECAMIOPR_COMPL_AU-AUSZDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ECAMIOPR_COMPL_AU you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ECAMIOPR_COMPL_AU TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ECAMIOPR_COMPL_AU INTO WA_ECAMIOPR_COMPL_AU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ECAMIOPR_COMPL_AU_STR,
BUPA_COMPL TYPE STRING,
ACC TYPE STRING,
CONT TYPE STRING,
CI TYPE STRING,
MR TYPE STRING,
GEN TYPE STRING,
LOCKED TYPE STRING,
PRGUID TYPE STRING,
XUCES TYPE STRING,
MO TYPE STRING,
AUSZDAT TYPE STRING,
DEPARTUREDATE TYPE STRING,
OHNEEINZ TYPE STRING,
MO_TEXT TYPE STRING,
AUTBEST TYPE STRING,
MI TYPE STRING,
EINZDAT TYPE STRING,
BEZUGSDAT TYPE STRING,
UEBADR TYPE STRING,
MI_TEXT TYPE STRING,
AUTBEGR TYPE STRING,
CUST TYPE STRING,
CONTACT TYPE STRING,
SAVE_IMMEDIATELY TYPE STRING,
NOTICE TYPE STRING,
USE_ONLY_MIO_DATES TYPE STRING,END OF T_EKKO_STR. DATA: WA_ECAMIOPR_COMPL_AU_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ECAMIOPR_COMPL_AU_STR-BUPA_COMPL sy-vline
WA_ECAMIOPR_COMPL_AU_STR-ACC sy-vline
WA_ECAMIOPR_COMPL_AU_STR-CONT sy-vline
WA_ECAMIOPR_COMPL_AU_STR-CI sy-vline
WA_ECAMIOPR_COMPL_AU_STR-MR sy-vline
WA_ECAMIOPR_COMPL_AU_STR-GEN sy-vline
WA_ECAMIOPR_COMPL_AU_STR-LOCKED sy-vline
WA_ECAMIOPR_COMPL_AU_STR-PRGUID sy-vline
WA_ECAMIOPR_COMPL_AU_STR-XUCES sy-vline
WA_ECAMIOPR_COMPL_AU_STR-MO sy-vline
WA_ECAMIOPR_COMPL_AU_STR-AUSZDAT sy-vline
WA_ECAMIOPR_COMPL_AU_STR-DEPARTUREDATE sy-vline
WA_ECAMIOPR_COMPL_AU_STR-OHNEEINZ sy-vline
WA_ECAMIOPR_COMPL_AU_STR-MO_TEXT sy-vline
WA_ECAMIOPR_COMPL_AU_STR-AUTBEST sy-vline
WA_ECAMIOPR_COMPL_AU_STR-MI sy-vline
WA_ECAMIOPR_COMPL_AU_STR-EINZDAT sy-vline
WA_ECAMIOPR_COMPL_AU_STR-BEZUGSDAT sy-vline
WA_ECAMIOPR_COMPL_AU_STR-UEBADR sy-vline
WA_ECAMIOPR_COMPL_AU_STR-MI_TEXT sy-vline
WA_ECAMIOPR_COMPL_AU_STR-AUTBEGR sy-vline
WA_ECAMIOPR_COMPL_AU_STR-CUST sy-vline
WA_ECAMIOPR_COMPL_AU_STR-CONTACT sy-vline
WA_ECAMIOPR_COMPL_AU_STR-SAVE_IMMEDIATELY sy-vline
WA_ECAMIOPR_COMPL_AU_STR-NOTICE sy-vline
WA_ECAMIOPR_COMPL_AU_STR-USE_ONLY_MIO_DATES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.