ABAP Select data from SAP table EAUSVD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAUSVD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAUSVD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAUSVD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAUSVD TYPE STANDARD TABLE OF EAUSVD,
      WA_EAUSVD TYPE EAUSVD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAUSVD> TYPE EAUSVD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAUSVD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAUSVD
  INTO TABLE IT_EAUSVD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAUSVD
*  INTO TABLE @DATA(IT_EAUSVD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAUSVD INDEX 1 INTO DATA(WA_EAUSVD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAUSVD ASSIGNING <EAUSVD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAUSVD>-MANDT = 1.
<EAUSVD>-AUSZBELEG = 1.
<EAUSVD>-VERTRAG = 1.
<EAUSVD>-VBEZ = 1.
<EAUSVD>-ANLAGE = 1.
ENDLOOP.

LOOP AT IT_EAUSVD INTO WA_EAUSVD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAUSVD-VSTELLE, sy-vline,
WA_EAUSVD-VBSADR, sy-vline,
WA_EAUSVD-OHNEEINZ, sy-vline,
WA_EAUSVD-OHNEEINZT, sy-vline,
WA_EAUSVD-MAHNV, sy-vline,
WA_EAUSVD-MAHNVT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAUSVD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAUSVD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAUSVD INTO WA_EAUSVD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUSZBELEG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAUSVD-AUSZBELEG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAUSVD-AUSZBELEG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERTRAG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAUSVD-VERTRAG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAUSVD-VERTRAG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLAGE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAUSVD-ANLAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAUSVD-ANLAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VSTELLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAUSVD-VSTELLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAUSVD-VSTELLE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EIGENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAUSVD-EIGENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAUSVD-EIGENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAUSVD_STR,
MANDT TYPE STRING,
AUSZBELEG TYPE STRING,
VERTRAG TYPE STRING,
VBEZ TYPE STRING,
ANLAGE TYPE STRING,
VSTELLE TYPE STRING,
VBSADR TYPE STRING,
OHNEEINZ TYPE STRING,
OHNEEINZT TYPE STRING,
MAHNV TYPE STRING,
MAHNVT TYPE STRING,
MANSP TYPE STRING,
MANSPT TYPE STRING,
AUSZDAT TYPE STRING,
AUSZSTAT TYPE STRING,
AUSZSTATT TYPE STRING,
WORKIT TYPE STRING,
AKLASSE TYPE STRING,
AKLASSET TYPE STRING,
SPARTE TYPE STRING,
SPARTET TYPE STRING,
BUKRS TYPE STRING,
BUKRST TYPE STRING,
ANLART TYPE STRING,
ANLARTT TYPE STRING,
VBSART TYPE STRING,
VBSARTT TYPE STRING,
KOFIZ TYPE STRING,
KOFIZT TYPE STRING,
GEMFAKT TYPE STRING,
PYPLT TYPE STRING,
PYPLTT TYPE STRING,
PYPLS TYPE STRING,
BEZUG TYPE STRING,
EIGENVERBR TYPE STRING,
MANABR TYPE STRING,
PAUSCHAL TYPE STRING,
EIGENT TYPE STRING,
NAMEEIGENT TYPE STRING,
MANOUTSORT TYPE STRING,
MANOUTSRTT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAUSVD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAUSVD_STR-MANDT sy-vline
WA_EAUSVD_STR-AUSZBELEG sy-vline
WA_EAUSVD_STR-VERTRAG sy-vline
WA_EAUSVD_STR-VBEZ sy-vline
WA_EAUSVD_STR-ANLAGE sy-vline
WA_EAUSVD_STR-VSTELLE sy-vline
WA_EAUSVD_STR-VBSADR sy-vline
WA_EAUSVD_STR-OHNEEINZ sy-vline
WA_EAUSVD_STR-OHNEEINZT sy-vline
WA_EAUSVD_STR-MAHNV sy-vline
WA_EAUSVD_STR-MAHNVT sy-vline
WA_EAUSVD_STR-MANSP sy-vline
WA_EAUSVD_STR-MANSPT sy-vline
WA_EAUSVD_STR-AUSZDAT sy-vline
WA_EAUSVD_STR-AUSZSTAT sy-vline
WA_EAUSVD_STR-AUSZSTATT sy-vline
WA_EAUSVD_STR-WORKIT sy-vline
WA_EAUSVD_STR-AKLASSE sy-vline
WA_EAUSVD_STR-AKLASSET sy-vline
WA_EAUSVD_STR-SPARTE sy-vline
WA_EAUSVD_STR-SPARTET sy-vline
WA_EAUSVD_STR-BUKRS sy-vline
WA_EAUSVD_STR-BUKRST sy-vline
WA_EAUSVD_STR-ANLART sy-vline
WA_EAUSVD_STR-ANLARTT sy-vline
WA_EAUSVD_STR-VBSART sy-vline
WA_EAUSVD_STR-VBSARTT sy-vline
WA_EAUSVD_STR-KOFIZ sy-vline
WA_EAUSVD_STR-KOFIZT sy-vline
WA_EAUSVD_STR-GEMFAKT sy-vline
WA_EAUSVD_STR-PYPLT sy-vline
WA_EAUSVD_STR-PYPLTT sy-vline
WA_EAUSVD_STR-PYPLS sy-vline
WA_EAUSVD_STR-BEZUG sy-vline
WA_EAUSVD_STR-EIGENVERBR sy-vline
WA_EAUSVD_STR-MANABR sy-vline
WA_EAUSVD_STR-PAUSCHAL sy-vline
WA_EAUSVD_STR-EIGENT sy-vline
WA_EAUSVD_STR-NAMEEIGENT sy-vline
WA_EAUSVD_STR-MANOUTSORT sy-vline
WA_EAUSVD_STR-MANOUTSRTT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.