ABAP Select data from SAP table EAUS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAUS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAUS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAUS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAUS TYPE STANDARD TABLE OF EAUS,
      WA_EAUS TYPE EAUS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAUS> TYPE EAUS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAUS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAUS
  INTO TABLE IT_EAUS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAUS
*  INTO TABLE @DATA(IT_EAUS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAUS INDEX 1 INTO DATA(WA_EAUS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAUS ASSIGNING <EAUS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAUS>-MANDT = 1.
<EAUS>-AUSZBELEG = 1.
<EAUS>-KUNDE = 1.
<EAUS>-VKONT = 1.
<EAUS>-BVAR = 1.
ENDLOOP.

LOOP AT IT_EAUS INTO WA_EAUS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAUS-VORLAUSZ, sy-vline,
WA_EAUS-DEBWECHS, sy-vline,
WA_EAUS-DEPARTUREDATE, sy-vline,
WA_EAUS-ABSSTOPKZ, sy-vline,
WA_EAUS-ABSSTOPANFO, sy-vline,
WA_EAUS-SCHLUSSRECH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAUS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAUS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAUS INTO WA_EAUS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AUSZBELEG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAUS-AUSZBELEG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAUS-AUSZBELEG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNDE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAUS-KUNDE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAUS-KUNDE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAUS-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAUS-VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VORLAUSZ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAUS-VORLAUSZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAUS-VORLAUSZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OPBEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAUS-OPBEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAUS-OPBEL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAUS_STR,
MANDT TYPE STRING,
AUSZBELEG TYPE STRING,
KUNDE TYPE STRING,
VKONT TYPE STRING,
BVAR TYPE STRING,
VORLAUSZ TYPE STRING,
DEBWECHS TYPE STRING,
DEPARTUREDATE TYPE STRING,
ABSSTOPKZ TYPE STRING,
ABSSTOPANFO TYPE STRING,
SCHLUSSRECH TYPE STRING,
BLDAT TYPE STRING,
BUDAT TYPE STRING,
OPBEL TYPE STRING,
AUTBEST TYPE STRING,
FORMBEST TYPE STRING,
ANZBEST TYPE STRING,
DELAYED_PRINT TYPE STRING,
AUSWFORM TYPE STRING,
AUTSICHWARN TYPE STRING,
BPC_CCLASS TYPE STRING,
BPC_ACTIVITY TYPE STRING,
BPC_ACTIVITY2 TYPE STRING,
GPVKCHDATE TYPE STRING,
FROMMOVEIN TYPE STRING,
GPVKREVERSE TYPE STRING,
STORGPART TYPE STRING,
STORKTO TYPE STRING,
STORAUSZ TYPE STRING,
SSWTCREASON TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
BEGRU TYPE STRING,
LOEVM TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAUS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAUS_STR-MANDT sy-vline
WA_EAUS_STR-AUSZBELEG sy-vline
WA_EAUS_STR-KUNDE sy-vline
WA_EAUS_STR-VKONT sy-vline
WA_EAUS_STR-BVAR sy-vline
WA_EAUS_STR-VORLAUSZ sy-vline
WA_EAUS_STR-DEBWECHS sy-vline
WA_EAUS_STR-DEPARTUREDATE sy-vline
WA_EAUS_STR-ABSSTOPKZ sy-vline
WA_EAUS_STR-ABSSTOPANFO sy-vline
WA_EAUS_STR-SCHLUSSRECH sy-vline
WA_EAUS_STR-BLDAT sy-vline
WA_EAUS_STR-BUDAT sy-vline
WA_EAUS_STR-OPBEL sy-vline
WA_EAUS_STR-AUTBEST sy-vline
WA_EAUS_STR-FORMBEST sy-vline
WA_EAUS_STR-ANZBEST sy-vline
WA_EAUS_STR-DELAYED_PRINT sy-vline
WA_EAUS_STR-AUSWFORM sy-vline
WA_EAUS_STR-AUTSICHWARN sy-vline
WA_EAUS_STR-BPC_CCLASS sy-vline
WA_EAUS_STR-BPC_ACTIVITY sy-vline
WA_EAUS_STR-BPC_ACTIVITY2 sy-vline
WA_EAUS_STR-GPVKCHDATE sy-vline
WA_EAUS_STR-FROMMOVEIN sy-vline
WA_EAUS_STR-GPVKREVERSE sy-vline
WA_EAUS_STR-STORGPART sy-vline
WA_EAUS_STR-STORKTO sy-vline
WA_EAUS_STR-STORAUSZ sy-vline
WA_EAUS_STR-SSWTCREASON sy-vline
WA_EAUS_STR-ERDAT sy-vline
WA_EAUS_STR-ERNAM sy-vline
WA_EAUS_STR-AEDAT sy-vline
WA_EAUS_STR-AENAM sy-vline
WA_EAUS_STR-BEGRU sy-vline
WA_EAUS_STR-LOEVM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.