ABAP Select data from SAP table EAMS_S_SP_TASKLIST_SEARCH_RSLT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMS_S_SP_TASKLIST_SEARCH_RSLT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMS_S_SP_TASKLIST_SEARCH_RSLT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAMS_S_SP_TASKLIST_SEARCH_RSLT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAMS_S_SP_TASKLIST_SEARCH_RSLT TYPE STANDARD TABLE OF EAMS_S_SP_TASKLIST_SEARCH_RSLT,
      WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT TYPE EAMS_S_SP_TASKLIST_SEARCH_RSLT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAMS_S_SP_TASKLIST_SEARCH_RSLT> TYPE EAMS_S_SP_TASKLIST_SEARCH_RSLT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAMS_S_SP_TASKLIST_SEARCH_RSLT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAMS_S_SP_TASKLIST_SEARCH_RSLT
  INTO TABLE IT_EAMS_S_SP_TASKLIST_SEARCH_RSLT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAMS_S_SP_TASKLIST_SEARCH_RSLT
*  INTO TABLE @DATA(IT_EAMS_S_SP_TASKLIST_SEARCH_RSLT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAMS_S_SP_TASKLIST_SEARCH_RSLT INDEX 1 INTO DATA(WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAMS_S_SP_TASKLIST_SEARCH_RSLT ASSIGNING <EAMS_S_SP_TASKLIST_SEARCH_RSLT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMS_S_SP_TASKLIST_SEARCH_RSLT>-QUERY_ID = 1.
<EAMS_S_SP_TASKLIST_SEARCH_RSLT>-OTYPE_NAME = 1.
<EAMS_S_SP_TASKLIST_SEARCH_RSLT>-OTYPE_DESC = 1.
<EAMS_S_SP_TASKLIST_SEARCH_RSLT>-OBJECT_ID = 1.
<EAMS_S_SP_TASKLIST_SEARCH_RSLT>-DISPLAY_KEY = 1.
ENDLOOP.

LOOP AT IT_EAMS_S_SP_TASKLIST_SEARCH_RSLT INTO WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-DESCRIPTION, sy-vline,
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-ICON_OBJECT_TYPE, sy-vline,
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-CONNECTOR_ID, sy-vline,
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-TASKLIST_KEY_CC, sy-vline,
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-KTEXT, sy-vline,
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-WERKS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMS_S_SP_TASKLIST_SEARCH_RSLT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMS_S_SP_TASKLIST_SEARCH_RSLT INTO WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field ISTRU CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-ISTRU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-ISTRU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR_EXT CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-TPLNR_EXT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-TPLNR_EXT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR_EXT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-EQUNR_EXT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-EQUNR_EXT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT-PLNAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR,
QUERY_ID TYPE STRING,
OTYPE_NAME TYPE STRING,
OTYPE_DESC TYPE STRING,
OBJECT_ID TYPE STRING,
DISPLAY_KEY TYPE STRING,
DESCRIPTION TYPE STRING,
ICON_OBJECT_TYPE TYPE STRING,
CONNECTOR_ID TYPE STRING,
TASKLIST_KEY_CC TYPE STRING,
KTEXT TYPE STRING,
WERKS TYPE STRING,
STATU TYPE STRING,
IWERK TYPE STRING,
STRAT TYPE STRING,
ISTRU TYPE STRING,
ANLZU TYPE STRING,
VERWE TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
TPLNR_EXT TYPE STRING,
EQUNR_EXT TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
DELKZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-QUERY_ID sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-OTYPE_NAME sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-OTYPE_DESC sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-OBJECT_ID sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-DISPLAY_KEY sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-DESCRIPTION sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-ICON_OBJECT_TYPE sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-CONNECTOR_ID sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-TASKLIST_KEY_CC sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-KTEXT sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-WERKS sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-STATU sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-IWERK sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-STRAT sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-ISTRU sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-ANLZU sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-VERWE sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-AEDAT sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-AENAM sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-TPLNR_EXT sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-EQUNR_EXT sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-PLNTY sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-PLNNR sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-PLNAL sy-vline
WA_EAMS_S_SP_TASKLIST_SEARCH_RSLT_STR-DELKZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.