ABAP Select data from SAP table EAMS_S_SP_ORD_OPER_PRT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMS_S_SP_ORD_OPER_PRT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMS_S_SP_ORD_OPER_PRT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAMS_S_SP_ORD_OPER_PRT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAMS_S_SP_ORD_OPER_PRT TYPE STANDARD TABLE OF EAMS_S_SP_ORD_OPER_PRT,
      WA_EAMS_S_SP_ORD_OPER_PRT TYPE EAMS_S_SP_ORD_OPER_PRT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAMS_S_SP_ORD_OPER_PRT> TYPE EAMS_S_SP_ORD_OPER_PRT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAMS_S_SP_ORD_OPER_PRT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAMS_S_SP_ORD_OPER_PRT
  INTO TABLE IT_EAMS_S_SP_ORD_OPER_PRT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAMS_S_SP_ORD_OPER_PRT
*  INTO TABLE @DATA(IT_EAMS_S_SP_ORD_OPER_PRT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAMS_S_SP_ORD_OPER_PRT INDEX 1 INTO DATA(WA_EAMS_S_SP_ORD_OPER_PRT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAMS_S_SP_ORD_OPER_PRT ASSIGNING <EAMS_S_SP_ORD_OPER_PRT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMS_S_SP_ORD_OPER_PRT>-EAMS_AUFNR = 1.
<EAMS_S_SP_ORD_OPER_PRT>-EAMS_VORNR = 1.
<EAMS_S_SP_ORD_OPER_PRT>-EAMS_UVORN = 1.
<EAMS_S_SP_ORD_OPER_PRT>-FHMAR = 1.
<EAMS_S_SP_ORD_OPER_PRT>-EAMS_PRTNR = 1.
ENDLOOP.

LOOP AT IT_EAMS_S_SP_ORD_OPER_PRT INTO WA_EAMS_S_SP_ORD_OPER_PRT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAMS_S_SP_ORD_OPER_PRT-ACTIVITY, sy-vline,
WA_EAMS_S_SP_ORD_OPER_PRT-ITEM_NO_OF_PRODUCTION_RESOURCE, sy-vline,
WA_EAMS_S_SP_ORD_OPER_PRT-PRT_PLANT, sy-vline,
WA_EAMS_S_SP_ORD_OPER_PRT-PRT_CATEGORY, sy-vline,
WA_EAMS_S_SP_ORD_OPER_PRT-PRT_NUMBER, sy-vline,
WA_EAMS_S_SP_ORD_OPER_PRT-MATERIAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMS_S_SP_ORD_OPER_PRT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMS_S_SP_ORD_OPER_PRT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMS_S_SP_ORD_OPER_PRT INTO WA_EAMS_S_SP_ORD_OPER_PRT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EAMS_AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-EAMS_AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-EAMS_AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field EAMS_VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-EAMS_VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-EAMS_VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field EAMS_UVORN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-EAMS_UVORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-EAMS_UVORN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FHMAR, internal->external for field FHMAR CALL FUNCTION 'CONVERSION_EXIT_FHMAR_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-FHMAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-FHMAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field ACTIVITY CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-ACTIVITY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-ACTIVITY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FHMAR, internal->external for field PRT_CATEGORY CALL FUNCTION 'CONVERSION_EXIT_FHMAR_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-PRT_CATEGORY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-PRT_CATEGORY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MISCELLANEOUS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-MISCELLANEOUS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-MISCELLANEOUS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOCUMENT_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-DOCUMENT_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-DOCUMENT_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field START_OFFSET_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-START_OFFSET_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-START_OFFSET_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field END_OFFSET_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-END_OFFSET_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-END_OFFSET_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_MEASURE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-PRT_MEASURE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-PRT_MEASURE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_USAGE_VALUE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-PRT_USAGE_VALUE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-PRT_USAGE_VALUE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_USAGE_QUANTITY_SUM_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-PRT_USAGE_QUANTITY_SUM_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-PRT_USAGE_QUANTITY_SUM_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_USAGE_VALUE_SUM_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-PRT_USAGE_VALUE_SUM_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-PRT_USAGE_VALUE_SUM_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRT_MEASUREMENT_POINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-PRT_MEASUREMENT_POINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-PRT_MEASUREMENT_POINT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRT_MEASUREMENT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-PRT_MEASUREMENT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-PRT_MEASUREMENT_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNL, internal->external for field MATERIAL_EXTERNAL CALL FUNCTION 'CONVERSION_EXIT_MATNL_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-MATERIAL_EXTERNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-MATERIAL_EXTERNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNW, internal->external for field MATERIAL_VERSION CALL FUNCTION 'CONVERSION_EXIT_MATNW_OUTPUT' EXPORTING input = WA_EAMS_S_SP_ORD_OPER_PRT-MATERIAL_VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_ORD_OPER_PRT-MATERIAL_VERSION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMS_S_SP_ORD_OPER_PRT_STR,
EAMS_AUFNR TYPE STRING,
EAMS_VORNR TYPE STRING,
EAMS_UVORN TYPE STRING,
FHMAR TYPE STRING,
EAMS_PRTNR TYPE STRING,
ACTIVITY TYPE STRING,
ITEM_NO_OF_PRODUCTION_RESOURCE TYPE STRING,
PRT_PLANT TYPE STRING,
PRT_CATEGORY TYPE STRING,
PRT_NUMBER TYPE STRING,
MATERIAL TYPE STRING,
MISCELLANEOUS TYPE STRING,
DOCUMENT_TYPE TYPE STRING,
DOCUMENT_NUMBER TYPE STRING,
DOCUMENT_PART TYPE STRING,
DOCUMENT_VERSION TYPE STRING,
EQUIPMENT TYPE STRING,
STD_TEXT_KEY TYPE STRING,
DESCRIPTION TYPE STRING,
CTRL_KEY TYPE STRING,
START_REF_DATE TYPE STRING,
START_OFFSET TYPE STRING,
START_OFFSET_UNIT TYPE STRING,
START_OFFSET_UNIT_ISO TYPE STRING,
END_REF_DATE TYPE STRING,
END_OFFSET TYPE STRING,
END_OFFSET_UNIT TYPE STRING,
END_OFFSET_UNIT_ISO TYPE STRING,
PRT_MEASURE_UNIT TYPE STRING,
PRT_MEASURE_UNIT_ISO TYPE STRING,
STD_VALUE_FOR_PRT_QTY TYPE STRING,
FORMULA_TOT_QTY TYPE STRING,
STD_USAGE_VALUE_FOR_PRT TYPE STRING,
PRT_USAGE_VALUE_UNIT TYPE STRING,
PRT_USAGE_VALUE_UNIT_ISO TYPE STRING,
FORMULA_TOT_USAGE TYPE STRING,
PRT_USAGE_QUANTITY_SUM TYPE STRING,
PRT_USAGE_QUANTITY_SUM_UNIT TYPE STRING,
PRT_USAGE_QUANTITY_SUM_UN_ISO TYPE STRING,
PRT_USAGE_VALUE_SUM TYPE STRING,
PRT_USAGE_VALUE_SUM_UNIT TYPE STRING,
PRT_USAGE_VALUE_SUM_UNIT_ISO TYPE STRING,
PRT_MEASUREMENT_POINT TYPE STRING,
PRT_MEASUREMENT_UNIT TYPE STRING,
PRT_MEASUREMENT_UNIT_ISO TYPE STRING,
PRT_ACTUAL_START_DATE TYPE STRING,
PRT_ACTUAL_START_TIME TYPE STRING,
PRT_ACTUAL_FINISH_DATE TYPE STRING,
PRT_ACTUAL_FINISH_TIME TYPE STRING,
PRT_STATUS TYPE STRING,
MATERIAL_EXTERNAL TYPE STRING,
MATERIAL_GUID TYPE STRING,
MATERIAL_VERSION TYPE STRING,
MAT_FHKTX TYPE STRING,
MIS_FHKTX TYPE STRING,
EQU_FHKTX TYPE STRING,
DOC_FHKTX TYPE STRING,
MSP_FHKTX TYPE STRING,
FAKTX TYPE STRING,
FHKTX TYPE STRING,
EAMS_PRT_USAGE_IND_START TYPE STRING,
EAMS_PRT_USAGE_IND_FINISH TYPE STRING,
PLANT_TXT TYPE STRING,
USA_VAL_UNIT_TXT TYPE STRING,
DOCUMENT_TYPE_TXT TYPE STRING,
CTRL_KEY_TXT TYPE STRING,
FORMULA_QTY_TXT TYPE STRING,
FORMULA_USAGE_TXT TYPE STRING,
REMAIN_USAGE_QUANTITY_UNIT_TXT TYPE STRING,
START_OFFSET_UNIT_TXT TYPE STRING,
END_OFFSET_UNIT_TXT TYPE STRING,
SAFETY_CHAR TYPE STRING,
PRT_IND TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMS_S_SP_ORD_OPER_PRT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-EAMS_AUFNR sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-EAMS_VORNR sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-EAMS_UVORN sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-FHMAR sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-EAMS_PRTNR sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-ACTIVITY sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-ITEM_NO_OF_PRODUCTION_RESOURCE sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_PLANT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_CATEGORY sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_NUMBER sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-MATERIAL sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-MISCELLANEOUS sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-DOCUMENT_TYPE sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-DOCUMENT_NUMBER sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-DOCUMENT_PART sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-DOCUMENT_VERSION sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-EQUIPMENT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-STD_TEXT_KEY sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-DESCRIPTION sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-CTRL_KEY sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-START_REF_DATE sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-START_OFFSET sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-START_OFFSET_UNIT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-START_OFFSET_UNIT_ISO sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-END_REF_DATE sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-END_OFFSET sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-END_OFFSET_UNIT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-END_OFFSET_UNIT_ISO sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_MEASURE_UNIT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_MEASURE_UNIT_ISO sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-STD_VALUE_FOR_PRT_QTY sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-FORMULA_TOT_QTY sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-STD_USAGE_VALUE_FOR_PRT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_USAGE_VALUE_UNIT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_USAGE_VALUE_UNIT_ISO sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-FORMULA_TOT_USAGE sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_USAGE_QUANTITY_SUM sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_USAGE_QUANTITY_SUM_UNIT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_USAGE_QUANTITY_SUM_UN_ISO sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_USAGE_VALUE_SUM sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_USAGE_VALUE_SUM_UNIT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_USAGE_VALUE_SUM_UNIT_ISO sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_MEASUREMENT_POINT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_MEASUREMENT_UNIT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_MEASUREMENT_UNIT_ISO sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_ACTUAL_START_DATE sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_ACTUAL_START_TIME sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_ACTUAL_FINISH_DATE sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_ACTUAL_FINISH_TIME sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_STATUS sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-MATERIAL_EXTERNAL sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-MATERIAL_GUID sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-MATERIAL_VERSION sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-MAT_FHKTX sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-MIS_FHKTX sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-EQU_FHKTX sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-DOC_FHKTX sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-MSP_FHKTX sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-FAKTX sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-FHKTX sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-EAMS_PRT_USAGE_IND_START sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-EAMS_PRT_USAGE_IND_FINISH sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PLANT_TXT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-USA_VAL_UNIT_TXT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-DOCUMENT_TYPE_TXT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-CTRL_KEY_TXT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-FORMULA_QTY_TXT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-FORMULA_USAGE_TXT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-REMAIN_USAGE_QUANTITY_UNIT_TXT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-START_OFFSET_UNIT_TXT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-END_OFFSET_UNIT_TXT sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-SAFETY_CHAR sy-vline
WA_EAMS_S_SP_ORD_OPER_PRT_STR-PRT_IND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.