ABAP Select data from SAP table EAMS_S_SP_MPOS_LIST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMS_S_SP_MPOS_LIST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMS_S_SP_MPOS_LIST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAMS_S_SP_MPOS_LIST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAMS_S_SP_MPOS_LIST TYPE STANDARD TABLE OF EAMS_S_SP_MPOS_LIST,
      WA_EAMS_S_SP_MPOS_LIST TYPE EAMS_S_SP_MPOS_LIST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAMS_S_SP_MPOS_LIST> TYPE EAMS_S_SP_MPOS_LIST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAMS_S_SP_MPOS_LIST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAMS_S_SP_MPOS_LIST
  INTO TABLE IT_EAMS_S_SP_MPOS_LIST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAMS_S_SP_MPOS_LIST
*  INTO TABLE @DATA(IT_EAMS_S_SP_MPOS_LIST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAMS_S_SP_MPOS_LIST INDEX 1 INTO DATA(WA_EAMS_S_SP_MPOS_LIST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAMS_S_SP_MPOS_LIST ASSIGNING <EAMS_S_SP_MPOS_LIST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMS_S_SP_MPOS_LIST>-EAMS_WAPOS = 1.
<EAMS_S_SP_MPOS_LIST>-PSTXT = 1.
<EAMS_S_SP_MPOS_LIST>-EAMS_TEC_OBJ_NO = 1.
<EAMS_S_SP_MPOS_LIST>-EAMS_TEC_OBJ_DES = 1.
<EAMS_S_SP_MPOS_LIST>-EAMS_TEC_OBJ_TYPE = 1.
ENDLOOP.

LOOP AT IT_EAMS_S_SP_MPOS_LIST INTO WA_EAMS_S_SP_MPOS_LIST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAMS_S_SP_MPOS_LIST-EAMS_TEC_OBJ_TYPE_DESC, sy-vline,
WA_EAMS_S_SP_MPOS_LIST-EAMS_OBJ_LIST_EXISTS, sy-vline,
WA_EAMS_S_SP_MPOS_LIST-IND_ABRVO, sy-vline,
WA_EAMS_S_SP_MPOS_LIST-EAMS_TL_AVAILABLE, sy-vline,
WA_EAMS_S_SP_MPOS_LIST-BAUTL, sy-vline,
WA_EAMS_S_SP_MPOS_LIST-SERIALNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMS_S_SP_MPOS_LIST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMS_S_SP_MPOS_LIST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMS_S_SP_MPOS_LIST INTO WA_EAMS_S_SP_MPOS_LIST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EAMS_WAPOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_SP_MPOS_LIST-EAMS_WAPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_MPOS_LIST-EAMS_WAPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BAUTL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMS_S_SP_MPOS_LIST-BAUTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_MPOS_LIST-BAUTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EAMS_S_SP_MPOS_LIST-SERIALNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_MPOS_LIST-SERIALNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field SERMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMS_S_SP_MPOS_LIST-SERMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_MPOS_LIST-SERMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PHYNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_SP_MPOS_LIST-PHYNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_SP_MPOS_LIST-PHYNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMS_S_SP_MPOS_LIST_STR,
EAMS_WAPOS TYPE STRING,
PSTXT TYPE STRING,
EAMS_TEC_OBJ_NO TYPE STRING,
EAMS_TEC_OBJ_DES TYPE STRING,
EAMS_TEC_OBJ_TYPE TYPE STRING,
EAMS_TEC_OBJ_TYPE_DESC TYPE STRING,
EAMS_OBJ_LIST_EXISTS TYPE STRING,
IND_ABRVO TYPE STRING,
EAMS_TL_AVAILABLE TYPE STRING,
BAUTL TYPE STRING,
SERIALNR TYPE STRING,
SERMAT TYPE STRING,
DEVICEID TYPE STRING,
PHYNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMS_S_SP_MPOS_LIST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-EAMS_WAPOS sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-PSTXT sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-EAMS_TEC_OBJ_NO sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-EAMS_TEC_OBJ_DES sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-EAMS_TEC_OBJ_TYPE sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-EAMS_TEC_OBJ_TYPE_DESC sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-EAMS_OBJ_LIST_EXISTS sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-IND_ABRVO sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-EAMS_TL_AVAILABLE sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-BAUTL sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-SERIALNR sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-SERMAT sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-DEVICEID sy-vline
WA_EAMS_S_SP_MPOS_LIST_STR-PHYNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.