ABAP Select data from SAP table EAMS_S_NAV_FL_ID_ATTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMS_S_NAV_FL_ID_ATTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMS_S_NAV_FL_ID_ATTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAMS_S_NAV_FL_ID_ATTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAMS_S_NAV_FL_ID_ATTR TYPE STANDARD TABLE OF EAMS_S_NAV_FL_ID_ATTR,
      WA_EAMS_S_NAV_FL_ID_ATTR TYPE EAMS_S_NAV_FL_ID_ATTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAMS_S_NAV_FL_ID_ATTR> TYPE EAMS_S_NAV_FL_ID_ATTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAMS_S_NAV_FL_ID_ATTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAMS_S_NAV_FL_ID_ATTR
  INTO TABLE IT_EAMS_S_NAV_FL_ID_ATTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAMS_S_NAV_FL_ID_ATTR
*  INTO TABLE @DATA(IT_EAMS_S_NAV_FL_ID_ATTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAMS_S_NAV_FL_ID_ATTR INDEX 1 INTO DATA(WA_EAMS_S_NAV_FL_ID_ATTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAMS_S_NAV_FL_ID_ATTR ASSIGNING <EAMS_S_NAV_FL_ID_ATTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMS_S_NAV_FL_ID_ATTR>-INTID = 1.
<EAMS_S_NAV_FL_ID_ATTR>-NAV_LOGSYS = 1.
<EAMS_S_NAV_FL_ID_ATTR>-DISPLAY_KEY = 1.
<EAMS_S_NAV_FL_ID_ATTR>-DESCRIPTION = 1.
<EAMS_S_NAV_FL_ID_ATTR>-EAMS_TEC_OBJ_NO = 1.
ENDLOOP.

LOOP AT IT_EAMS_S_NAV_FL_ID_ATTR INTO WA_EAMS_S_NAV_FL_ID_ATTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAMS_S_NAV_FL_ID_ATTR-EAMS_TEC_OBJ_DES, sy-vline,
WA_EAMS_S_NAV_FL_ID_ATTR-EAMS_TEC_OBJ_TYPE, sy-vline,
WA_EAMS_S_NAV_FL_ID_ATTR-EAMS_TEC_OBJ_TYP_ICON, sy-vline,
WA_EAMS_S_NAV_FL_ID_ATTR-EAMS_TEC_OBJ_TYPE_DES, sy-vline,
WA_EAMS_S_NAV_FL_ID_ATTR-AUTHGRP, sy-vline,
WA_EAMS_S_NAV_FL_ID_ATTR-OBJECTTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMS_S_NAV_FL_ID_ATTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMS_S_NAV_FL_ID_ATTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMS_S_NAV_FL_ID_ATTR INTO WA_EAMS_S_NAV_FL_ID_ATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field NAV_LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-NAV_LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-NAV_LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_WT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-UNIT_OF_WT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-UNIT_OF_WT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field CONSTYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-CONSTYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-CONSTYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field CONSTTYPE CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-CONSTTYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-CONSTTYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-COSTCENTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field WBS_ELEM CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-WBS_ELEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-WBS_ELEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ASSET_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-ASSET_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-ASSET_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUB_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-SUB_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-SUB_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STANDORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-STANDORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-STANDORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SETTLORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-SETTLORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-SETTLORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field READ_ADRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-READ_ADRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-READ_ADRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNL, internal->external for field CONSTTYPE_EXTERNAL CALL FUNCTION 'CONVERSION_EXIT_MATNL_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-CONSTTYPE_EXTERNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-CONSTTYPE_EXTERNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNW, internal->external for field CONSTTYPE_VERSION CALL FUNCTION 'CONVERSION_EXIT_MATNW_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-CONSTTYPE_VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-CONSTTYPE_VERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LINEAR_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-LINEAR_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-LINEAR_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FIRST_OFFSET_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-FIRST_OFFSET_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-FIRST_OFFSET_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SECOND_OFFSET_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-SECOND_OFFSET_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-SECOND_OFFSET_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MARKER_DISTANCE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_NAV_FL_ID_ATTR-MARKER_DISTANCE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_NAV_FL_ID_ATTR-MARKER_DISTANCE_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMS_S_NAV_FL_ID_ATTR_STR,
INTID TYPE STRING,
NAV_LOGSYS TYPE STRING,
DISPLAY_KEY TYPE STRING,
DESCRIPTION TYPE STRING,
EAMS_TEC_OBJ_NO TYPE STRING,
EAMS_TEC_OBJ_DES TYPE STRING,
EAMS_TEC_OBJ_TYPE TYPE STRING,
EAMS_TEC_OBJ_TYP_ICON TYPE STRING,
EAMS_TEC_OBJ_TYPE_DES TYPE STRING,
AUTHGRP TYPE STRING,
OBJECTTYPE TYPE STRING,
INVENTORY TYPE STRING,
OBJ_SIZE TYPE STRING,
OBJ_WEIGHT TYPE STRING,
UNIT_OF_WT TYPE STRING,
UNIT_ISO TYPE STRING,
ACQDATE TYPE STRING,
ACQUISVAL TYPE STRING,
CURRENCY TYPE STRING,
CURR_ISO TYPE STRING,
MANFACTURE TYPE STRING,
MANCOUNTRY TYPE STRING,
COUNTR_ISO TYPE STRING,
MANSERNO TYPE STRING,
MANMODEL TYPE STRING,
CONSTYEAR TYPE STRING,
CONSTMONTH TYPE STRING,
START_FROM TYPE STRING,
PLANPLANT TYPE STRING,
CONSTTYPE TYPE STRING,
MANPARNO TYPE STRING,
PLANGROUP TYPE STRING,
CATPROFILE TYPE STRING,
WORK_CTR TYPE STRING,
DESCRIPT TYPE STRING,
ABCINDIC TYPE STRING,
SORTFIELD TYPE STRING,
MAINTPLANT TYPE STRING,
MAINTLOC TYPE STRING,
MAINTROOM TYPE STRING,
PLSECTN TYPE STRING,
PP_WKCTR TYPE STRING,
BUS_AREA TYPE STRING,
COSTCENTER TYPE STRING,
WBS_ELEM TYPE STRING,
COMP_CODE TYPE STRING,
ASSET_NO TYPE STRING,
SUB_NUMBER TYPE STRING,
STANDORDER TYPE STRING,
SETTLORDER TYPE STRING,
SALES_ORG TYPE STRING,
DISTR_CHAN TYPE STRING,
DIVISION TYPE STRING,
SALES_OFF TYPE STRING,
SALES_GRP TYPE STRING,
READ_CRDAT TYPE STRING,
READ_CRNAM TYPE STRING,
READ_CHDAT TYPE STRING,
READ_CHNAM TYPE STRING,
READ_ADRNR TYPE STRING,
CONSTTYPE_EXTERNAL TYPE STRING,
CONSTTYPE_GUID TYPE STRING,
CONSTTYPE_VERSION TYPE STRING,
READ_OBJNR TYPE STRING,
SHIFT_REPORT_TYPE TYPE STRING,
SHIFT_NOTE_NOTIFICATION_TYPE TYPE STRING,
START_POINT TYPE STRING,
END_POINT TYPE STRING,
LINEAR_LENGTH TYPE STRING,
LINEAR_UNIT TYPE STRING,
FIRST_OFFSET_TYPE_CODE TYPE STRING,
FIRST_OFFSET_VALUE TYPE STRING,
FIRST_OFFSET_UNIT TYPE STRING,
SECOND_OFFSET_TYPE_CODE TYPE STRING,
SECOND_OFFSET_VALUE TYPE STRING,
SECOND_OFFSET_UNIT TYPE STRING,
SECOND_OFFSET_UNIT_ISO TYPE STRING,
LINEAR_UNIT_ISO TYPE STRING,
FIRST_OFFSET_UNIT_ISO TYPE STRING,
LINEAR_REFERENCE_PATTERN TYPE STRING,
MARKER_START_POINT TYPE STRING,
MARKER_DISTANCE_START_POINT TYPE STRING,
MARKER_END_POINT TYPE STRING,
MARKER_DISTANCE_END_POINT TYPE STRING,
MARKER_DISTANCE_UNIT TYPE STRING,
MARKER_DISTANCE_UNIT_ISO TYPE STRING,
END_TO TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMS_S_NAV_FL_ID_ATTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-INTID sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-NAV_LOGSYS sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-DISPLAY_KEY sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-DESCRIPTION sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-EAMS_TEC_OBJ_NO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-EAMS_TEC_OBJ_DES sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-EAMS_TEC_OBJ_TYPE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-EAMS_TEC_OBJ_TYP_ICON sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-EAMS_TEC_OBJ_TYPE_DES sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-AUTHGRP sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-OBJECTTYPE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-INVENTORY sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-OBJ_SIZE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-OBJ_WEIGHT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-UNIT_OF_WT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-UNIT_ISO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-ACQDATE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-ACQUISVAL sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-CURRENCY sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-CURR_ISO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MANFACTURE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MANCOUNTRY sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-COUNTR_ISO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MANSERNO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MANMODEL sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-CONSTYEAR sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-CONSTMONTH sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-START_FROM sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-PLANPLANT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-CONSTTYPE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MANPARNO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-PLANGROUP sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-CATPROFILE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-WORK_CTR sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-DESCRIPT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-ABCINDIC sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SORTFIELD sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MAINTPLANT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MAINTLOC sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MAINTROOM sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-PLSECTN sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-PP_WKCTR sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-BUS_AREA sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-COSTCENTER sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-WBS_ELEM sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-COMP_CODE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-ASSET_NO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SUB_NUMBER sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-STANDORDER sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SETTLORDER sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SALES_ORG sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-DISTR_CHAN sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-DIVISION sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SALES_OFF sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SALES_GRP sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-READ_CRDAT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-READ_CRNAM sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-READ_CHDAT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-READ_CHNAM sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-READ_ADRNR sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-CONSTTYPE_EXTERNAL sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-CONSTTYPE_GUID sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-CONSTTYPE_VERSION sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-READ_OBJNR sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SHIFT_REPORT_TYPE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SHIFT_NOTE_NOTIFICATION_TYPE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-START_POINT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-END_POINT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-LINEAR_LENGTH sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-LINEAR_UNIT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-FIRST_OFFSET_TYPE_CODE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-FIRST_OFFSET_VALUE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-FIRST_OFFSET_UNIT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SECOND_OFFSET_TYPE_CODE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SECOND_OFFSET_VALUE sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SECOND_OFFSET_UNIT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-SECOND_OFFSET_UNIT_ISO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-LINEAR_UNIT_ISO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-FIRST_OFFSET_UNIT_ISO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-LINEAR_REFERENCE_PATTERN sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MARKER_START_POINT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MARKER_DISTANCE_START_POINT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MARKER_END_POINT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MARKER_DISTANCE_END_POINT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MARKER_DISTANCE_UNIT sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-MARKER_DISTANCE_UNIT_ISO sy-vline
WA_EAMS_S_NAV_FL_ID_ATTR_STR-END_TO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.