ABAP Select data from SAP table EAMS_S_GEF_SRV_EQUI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMS_S_GEF_SRV_EQUI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMS_S_GEF_SRV_EQUI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAMS_S_GEF_SRV_EQUI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAMS_S_GEF_SRV_EQUI TYPE STANDARD TABLE OF EAMS_S_GEF_SRV_EQUI,
      WA_EAMS_S_GEF_SRV_EQUI TYPE EAMS_S_GEF_SRV_EQUI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAMS_S_GEF_SRV_EQUI> TYPE EAMS_S_GEF_SRV_EQUI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAMS_S_GEF_SRV_EQUI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAMS_S_GEF_SRV_EQUI
  INTO TABLE IT_EAMS_S_GEF_SRV_EQUI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAMS_S_GEF_SRV_EQUI
*  INTO TABLE @DATA(IT_EAMS_S_GEF_SRV_EQUI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAMS_S_GEF_SRV_EQUI INDEX 1 INTO DATA(WA_EAMS_S_GEF_SRV_EQUI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAMS_S_GEF_SRV_EQUI ASSIGNING <EAMS_S_GEF_SRV_EQUI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMS_S_GEF_SRV_EQUI>-LONG_TEXT = 1.
<EAMS_S_GEF_SRV_EQUI>-SYS_STAT_UI_TEXT = 1.
<EAMS_S_GEF_SRV_EQUI>-USR_STAT_UI_TEXT = 1.
<EAMS_S_GEF_SRV_EQUI>-OBJ_TYPE_UI_TEXT = 1.
<EAMS_S_GEF_SRV_EQUI>-OBJ_CAT_UI_TEXT = 1.
ENDLOOP.

LOOP AT IT_EAMS_S_GEF_SRV_EQUI INTO WA_EAMS_S_GEF_SRV_EQUI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAMS_S_GEF_SRV_EQUI-INACTIVE, sy-vline,
WA_EAMS_S_GEF_SRV_EQUI-EAMS_EQUNR, sy-vline,
WA_EAMS_S_GEF_SRV_EQUI-AUTHGRP, sy-vline,
WA_EAMS_S_GEF_SRV_EQUI-OBJECTTYPE, sy-vline,
WA_EAMS_S_GEF_SRV_EQUI-INVENTORY, sy-vline,
WA_EAMS_S_GEF_SRV_EQUI-OBJ_SIZE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMS_S_GEF_SRV_EQUI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMS_S_GEF_SRV_EQUI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMS_S_GEF_SRV_EQUI INTO WA_EAMS_S_GEF_SRV_EQUI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EAMS_EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-EAMS_EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-EAMS_EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_WT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-UNIT_OF_WT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-UNIT_OF_WT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field CONSTYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-CONSTYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-CONSTYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field CONSTTYPE CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-CONSTTYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-CONSTTYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-COSTCENTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field WBS_ELEM CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-WBS_ELEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-WBS_ELEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ASSET_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-ASSET_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-ASSET_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUB_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-SUB_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-SUB_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STANDORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-STANDORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-STANDORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SETTLORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-SETTLORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-SETTLORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field READ_ADRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-READ_ADRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-READ_ADRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNL, internal->external for field CONSTTYPE_EXTERNAL CALL FUNCTION 'CONVERSION_EXIT_MATNL_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-CONSTTYPE_EXTERNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-CONSTTYPE_EXTERNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNW, internal->external for field CONSTTYPE_VERSION CALL FUNCTION 'CONVERSION_EXIT_MATNW_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-CONSTTYPE_VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-CONSTTYPE_VERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LINEAR_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-LINEAR_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-LINEAR_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FIRST_OFFSET_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-FIRST_OFFSET_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-FIRST_OFFSET_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SECOND_OFFSET_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-SECOND_OFFSET_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-SECOND_OFFSET_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MARKER_DISTANCE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-MARKER_DISTANCE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-MARKER_DISTANCE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field CONFIGMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-CONFIGMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-CONFIGMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNO CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-SERIALNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-SERIALNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field READ_SUPEQ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-READ_SUPEQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-READ_SUPEQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNL, internal->external for field CONFIGMAT_EXTERNAL CALL FUNCTION 'CONVERSION_EXIT_MATNL_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-CONFIGMAT_EXTERNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-CONFIGMAT_EXTERNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNW, internal->external for field CONFIGMAT_VERSION CALL FUNCTION 'CONVERSION_EXIT_MATNW_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-CONFIGMAT_VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-CONFIGMAT_VERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNL, internal->external for field MATERIAL_EXTERNAL CALL FUNCTION 'CONVERSION_EXIT_MATNL_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-MATERIAL_EXTERNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-MATERIAL_EXTERNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATNW, internal->external for field MATERIAL_VERSION CALL FUNCTION 'CONVERSION_EXIT_MATNW_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-MATERIAL_VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-MATERIAL_VERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field READ_MAINTENANCE_PLAN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-READ_MAINTENANCE_PLAN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-READ_MAINTENANCE_PLAN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field READ_MEASURING_POINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-READ_MEASURING_POINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-READ_MEASURING_POINT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DIM_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-DIM_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-DIM_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_POWER CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-UNIT_POWER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-UNIT_POWER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_CAP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-UNIT_CAP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-UNIT_CAP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WGT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-WGT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-WGT_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LOAD_DIM_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-LOAD_DIM_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-LOAD_DIM_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOL_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-VOL_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-VOL_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field SPEED_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMS_S_GEF_SRV_EQUI-SPEED_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMS_S_GEF_SRV_EQUI-SPEED_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMS_S_GEF_SRV_EQUI_STR,
LONG_TEXT TYPE STRING,
SYS_STAT_UI_TEXT TYPE STRING,
USR_STAT_UI_TEXT TYPE STRING,
OBJ_TYPE_UI_TEXT TYPE STRING,
OBJ_CAT_UI_TEXT TYPE STRING,
INACTIVE TYPE STRING,
EAMS_EQUNR TYPE STRING,
AUTHGRP TYPE STRING,
OBJECTTYPE TYPE STRING,
INVENTORY TYPE STRING,
OBJ_SIZE TYPE STRING,
OBJ_WEIGHT TYPE STRING,
UNIT_OF_WT TYPE STRING,
UNIT_ISO TYPE STRING,
ACQDATE TYPE STRING,
ACQUISVAL TYPE STRING,
CURRENCY TYPE STRING,
CURR_ISO TYPE STRING,
MANFACTURE TYPE STRING,
MANCOUNTRY TYPE STRING,
COUNTR_ISO TYPE STRING,
MANSERNO TYPE STRING,
MANMODEL TYPE STRING,
CONSTYEAR TYPE STRING,
CONSTMONTH TYPE STRING,
START_FROM TYPE STRING,
PLANPLANT TYPE STRING,
CONSTTYPE TYPE STRING,
MANPARNO TYPE STRING,
PLANGROUP TYPE STRING,
CATPROFILE TYPE STRING,
WORK_CTR TYPE STRING,
DESCRIPT TYPE STRING,
ABCINDIC TYPE STRING,
SORTFIELD TYPE STRING,
MAINTPLANT TYPE STRING,
MAINTLOC TYPE STRING,
MAINTROOM TYPE STRING,
PLSECTN TYPE STRING,
PP_WKCTR TYPE STRING,
BUS_AREA TYPE STRING,
COSTCENTER TYPE STRING,
WBS_ELEM TYPE STRING,
COMP_CODE TYPE STRING,
ASSET_NO TYPE STRING,
SUB_NUMBER TYPE STRING,
STANDORDER TYPE STRING,
SETTLORDER TYPE STRING,
SALES_ORG TYPE STRING,
DISTR_CHAN TYPE STRING,
DIVISION TYPE STRING,
SALES_OFF TYPE STRING,
SALES_GRP TYPE STRING,
READ_CRDAT TYPE STRING,
READ_CRNAM TYPE STRING,
READ_CHDAT TYPE STRING,
READ_CHNAM TYPE STRING,
READ_ADRNR TYPE STRING,
CONSTTYPE_EXTERNAL TYPE STRING,
CONSTTYPE_GUID TYPE STRING,
CONSTTYPE_VERSION TYPE STRING,
READ_OBJNR TYPE STRING,
SHIFT_REPORT_TYPE TYPE STRING,
SHIFT_NOTE_NOTIFICATION_TYPE TYPE STRING,
START_POINT TYPE STRING,
END_POINT TYPE STRING,
LINEAR_LENGTH TYPE STRING,
LINEAR_UNIT TYPE STRING,
FIRST_OFFSET_TYPE_CODE TYPE STRING,
FIRST_OFFSET_VALUE TYPE STRING,
FIRST_OFFSET_UNIT TYPE STRING,
SECOND_OFFSET_TYPE_CODE TYPE STRING,
SECOND_OFFSET_VALUE TYPE STRING,
SECOND_OFFSET_UNIT TYPE STRING,
SECOND_OFFSET_UNIT_ISO TYPE STRING,
LINEAR_UNIT_ISO TYPE STRING,
FIRST_OFFSET_UNIT_ISO TYPE STRING,
LINEAR_REFERENCE_PATTERN TYPE STRING,
MARKER_START_POINT TYPE STRING,
MARKER_DISTANCE_START_POINT TYPE STRING,
MARKER_END_POINT TYPE STRING,
MARKER_DISTANCE_END_POINT TYPE STRING,
MARKER_DISTANCE_UNIT TYPE STRING,
MARKER_DISTANCE_UNIT_ISO TYPE STRING,
CONFIGMAT TYPE STRING,
MATERIAL TYPE STRING,
SERIALNO TYPE STRING,
EQUICATGRY TYPE STRING,
BATCH TYPE STRING,
MANDRAWNO TYPE STRING,
DELIVDATE TYPE STRING,
FREE_DATE1 TYPE STRING,
FREE_NOTE1 TYPE STRING,
FREE_NUM1 TYPE STRING,
TECHID TYPE STRING,
LICENSE TYPE STRING,
FREE_DATE2 TYPE STRING,
FREE_NOTE2 TYPE STRING,
FREE_NUM2 TYPE STRING,
READ_CUOBJ TYPE STRING,
READ_CUREF TYPE STRING,
READ_SUPEQ TYPE STRING,
READ_FLOC TYPE STRING,
INST_POS TYPE STRING,
CONFIGMAT_EXTERNAL TYPE STRING,
CONFIGMAT_GUID TYPE STRING,
CONFIGMAT_VERSION TYPE STRING,
MATERIAL_EXTERNAL TYPE STRING,
MATERIAL_GUID TYPE STRING,
MATERIAL_VERSION TYPE STRING,
CONFIG_CONTROL_IND TYPE STRING,
IPPE_GUID TYPE STRING,
TECHS TYPE STRING,
FUNC_ID TYPE STRING,
UII TYPE STRING,
IUID_TYPE TYPE STRING,
UII_PLANT TYPE STRING,
READ_MAINTENANCE_PLAN TYPE STRING,
READ_MEASURING_POINT TYPE STRING,
READ_VALID_FROM TYPE STRING,
FLEET_NUM TYPE STRING,
FLEET_VIN TYPE STRING,
CHASSIS_NUM TYPE STRING,
LICENSE_NUM TYPE STRING,
EXPIRY_DATE TYPE STRING,
FLEET_HGT TYPE STRING,
FLEET_WID TYPE STRING,
FLEET_LEN TYPE STRING,
DIM_UNIT TYPE STRING,
DIM_UNIT_ISO TYPE STRING,
PRI_CALC TYPE STRING,
REPLA_DATE TYPE STRING,
REPLA_ODOM TYPE STRING,
REPLA_OPH TYPE STRING,
NUM_AXLE TYPE STRING,
MAX_OCCUPANTS TYPE STRING,
CARD_NUM TYPE STRING,
KEY_NUM TYPE STRING,
FLEET_USE TYPE STRING,
ENGINE_TYPE TYPE STRING,
ENGINE_POWER TYPE STRING,
UNIT_POWER TYPE STRING,
UNIT_POWER_ISO TYPE STRING,
REVOLUTIONS TYPE STRING,
ENGINE_CYL TYPE STRING,
ENGINE_CAP TYPE STRING,
UNIT_CAP TYPE STRING,
UNIT_CAP_ISO TYPE STRING,
ENGINE_SNR TYPE STRING,
FUEL_PRI TYPE STRING,
FUEL_SEC TYPE STRING,
OIL_TYPE TYPE STRING,
GROSS_WGT TYPE STRING,
LOAD_WGT TYPE STRING,
WGT_UNIT TYPE STRING,
WGT_UNIT_ISO TYPE STRING,
LOAD_HGT TYPE STRING,
LOAD_WID TYPE STRING,
LOAD_LEN TYPE STRING,
LOAD_DIM_UNIT TYPE STRING,
LOAD_DIM_UNIT_ISO TYPE STRING,
LOAD_VOL TYPE STRING,
VOL_UNIT TYPE STRING,
VOL_UNIT_ISO TYPE STRING,
NO_COMPART TYPE STRING,
SPEED_MAX TYPE STRING,
SPEED_UNIT TYPE STRING,
SPEED_UNIT_ISO TYPE STRING,
CONSUMP_TOL TYPE STRING,
CONSUMP_MOVE TYPE STRING,
EAMS_OBJNR TYPE STRING,
EAMS_TEC_OBJ_TYPE TYPE STRING,
EAMS_TEC_OBJ_TYPE_TXT TYPE STRING,
PLANPLANT_TXT TYPE STRING,
PLANGROUP_TXT TYPE STRING,
ABCINDIC_TXT TYPE STRING,
MAINTPLANT_TXT TYPE STRING,
PLSECTN_TXT TYPE STRING,
COSTCENTER_TXT TYPE STRING,
WBS_ELEM_TXT TYPE STRING,
COMP_CODE_TXT TYPE STRING,
ASSET_NO_TXT TYPE STRING,
SALES_ORG_TXT TYPE STRING,
DISTR_CHAN_TXT TYPE STRING,
DIVISION_TXT TYPE STRING,
MAINTLOC_TXT TYPE STRING,
OBJECTTYPE_TXT TYPE STRING,
UNIT_OF_WT_TXT TYPE STRING,
CONSTTYPE_TXT TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,
WERGW TYPE STRING,
MAIN_WORK_CENTER TYPE STRING,
SWERK TYPE STRING,
LOC_WORK_CENTER TYPE STRING,
MAIN_WORK_CENTER_DESCR TYPE STRING,
WORK_CENTER_DESCR TYPE STRING,
MAINTPLANT_DESCR TYPE STRING,
SYS_STATUS TYPE STRING,
USERSTATUS TYPE STRING,
PLANT_TXT TYPE STRING,
EAML_LFE_IND TYPE STRING,
LINEAR_UNIT_TXT TYPE STRING,
MARKER_DISTANCE_UNIT_TXT TYPE STRING,
FIRST_OFFSET_UNIT_TXT TYPE STRING,
SECOND_OFFSET_UNIT_TXT TYPE STRING,
EQUICATGRY_TXT TYPE STRING,
INSTALLATIONLOCATION TYPE STRING,
INSTALLATIONLOCATION_LABEL TYPE STRING,
SAFETY_CHAR TYPE STRING,
PRT_IND TYPE STRING,
SAFETY_CHAR_TXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMS_S_GEF_SRV_EQUI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LONG_TEXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SYS_STAT_UI_TEXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-USR_STAT_UI_TEXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-OBJ_TYPE_UI_TEXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-OBJ_CAT_UI_TEXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-INACTIVE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-EAMS_EQUNR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-AUTHGRP sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-OBJECTTYPE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-INVENTORY sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-OBJ_SIZE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-OBJ_WEIGHT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-UNIT_OF_WT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-UNIT_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ACQDATE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ACQUISVAL sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CURRENCY sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CURR_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MANFACTURE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MANCOUNTRY sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-COUNTR_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MANSERNO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MANMODEL sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONSTYEAR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONSTMONTH sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-START_FROM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-PLANPLANT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONSTTYPE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MANPARNO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-PLANGROUP sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CATPROFILE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-WORK_CTR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-DESCRIPT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ABCINDIC sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SORTFIELD sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MAINTPLANT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MAINTLOC sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MAINTROOM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-PLSECTN sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-PP_WKCTR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-BUS_AREA sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-COSTCENTER sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-WBS_ELEM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-COMP_CODE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ASSET_NO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SUB_NUMBER sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-STANDORDER sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SETTLORDER sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SALES_ORG sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-DISTR_CHAN sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-DIVISION sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SALES_OFF sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SALES_GRP sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_CRDAT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_CRNAM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_CHDAT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_CHNAM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_ADRNR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONSTTYPE_EXTERNAL sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONSTTYPE_GUID sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONSTTYPE_VERSION sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_OBJNR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SHIFT_REPORT_TYPE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SHIFT_NOTE_NOTIFICATION_TYPE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-START_POINT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-END_POINT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LINEAR_LENGTH sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LINEAR_UNIT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FIRST_OFFSET_TYPE_CODE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FIRST_OFFSET_VALUE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FIRST_OFFSET_UNIT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SECOND_OFFSET_TYPE_CODE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SECOND_OFFSET_VALUE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SECOND_OFFSET_UNIT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SECOND_OFFSET_UNIT_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LINEAR_UNIT_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FIRST_OFFSET_UNIT_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LINEAR_REFERENCE_PATTERN sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MARKER_START_POINT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MARKER_DISTANCE_START_POINT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MARKER_END_POINT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MARKER_DISTANCE_END_POINT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MARKER_DISTANCE_UNIT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MARKER_DISTANCE_UNIT_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONFIGMAT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MATERIAL sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SERIALNO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-EQUICATGRY sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-BATCH sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MANDRAWNO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-DELIVDATE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FREE_DATE1 sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FREE_NOTE1 sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FREE_NUM1 sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-TECHID sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LICENSE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FREE_DATE2 sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FREE_NOTE2 sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FREE_NUM2 sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_CUOBJ sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_CUREF sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_SUPEQ sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_FLOC sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-INST_POS sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONFIGMAT_EXTERNAL sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONFIGMAT_GUID sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONFIGMAT_VERSION sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MATERIAL_EXTERNAL sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MATERIAL_GUID sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MATERIAL_VERSION sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONFIG_CONTROL_IND sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-IPPE_GUID sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-TECHS sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FUNC_ID sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-UII sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-IUID_TYPE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-UII_PLANT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_MAINTENANCE_PLAN sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_MEASURING_POINT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-READ_VALID_FROM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FLEET_NUM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FLEET_VIN sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CHASSIS_NUM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LICENSE_NUM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-EXPIRY_DATE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FLEET_HGT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FLEET_WID sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FLEET_LEN sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-DIM_UNIT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-DIM_UNIT_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-PRI_CALC sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-REPLA_DATE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-REPLA_ODOM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-REPLA_OPH sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-NUM_AXLE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MAX_OCCUPANTS sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CARD_NUM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-KEY_NUM sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FLEET_USE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ENGINE_TYPE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ENGINE_POWER sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-UNIT_POWER sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-UNIT_POWER_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-REVOLUTIONS sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ENGINE_CYL sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ENGINE_CAP sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-UNIT_CAP sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-UNIT_CAP_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ENGINE_SNR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FUEL_PRI sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FUEL_SEC sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-OIL_TYPE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-GROSS_WGT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LOAD_WGT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-WGT_UNIT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-WGT_UNIT_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LOAD_HGT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LOAD_WID sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LOAD_LEN sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LOAD_DIM_UNIT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LOAD_DIM_UNIT_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LOAD_VOL sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-VOL_UNIT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-VOL_UNIT_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-NO_COMPART sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SPEED_MAX sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SPEED_UNIT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SPEED_UNIT_ISO sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONSUMP_TOL sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONSUMP_MOVE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-EAMS_OBJNR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-EAMS_TEC_OBJ_TYPE sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-EAMS_TEC_OBJ_TYPE_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-PLANPLANT_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-PLANGROUP_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ABCINDIC_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MAINTPLANT_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-PLSECTN_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-COSTCENTER_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-WBS_ELEM_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-COMP_CODE_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-ASSET_NO_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SALES_ORG_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-DISTR_CHAN_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-DIVISION_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MAINTLOC_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-OBJECTTYPE_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-UNIT_OF_WT_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-CONSTTYPE_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-DATAB sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-DATBI sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-WERGW sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MAIN_WORK_CENTER sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SWERK sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LOC_WORK_CENTER sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MAIN_WORK_CENTER_DESCR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-WORK_CENTER_DESCR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MAINTPLANT_DESCR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SYS_STATUS sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-USERSTATUS sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-PLANT_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-EAML_LFE_IND sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-LINEAR_UNIT_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-MARKER_DISTANCE_UNIT_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-FIRST_OFFSET_UNIT_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SECOND_OFFSET_UNIT_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-EQUICATGRY_TXT sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-INSTALLATIONLOCATION sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-INSTALLATIONLOCATION_LABEL sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SAFETY_CHAR sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-PRT_IND sy-vline
WA_EAMS_S_GEF_SRV_EQUI_STR-SAFETY_CHAR_TXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.