ABAP Select data from SAP table EAMS_S_BO_TLOP_DESCR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMS_S_BO_TLOP_DESCR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMS_S_BO_TLOP_DESCR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAMS_S_BO_TLOP_DESCR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAMS_S_BO_TLOP_DESCR TYPE STANDARD TABLE OF EAMS_S_BO_TLOP_DESCR,
      WA_EAMS_S_BO_TLOP_DESCR TYPE EAMS_S_BO_TLOP_DESCR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAMS_S_BO_TLOP_DESCR> TYPE EAMS_S_BO_TLOP_DESCR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAMS_S_BO_TLOP_DESCR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAMS_S_BO_TLOP_DESCR
  INTO TABLE IT_EAMS_S_BO_TLOP_DESCR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAMS_S_BO_TLOP_DESCR
*  INTO TABLE @DATA(IT_EAMS_S_BO_TLOP_DESCR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAMS_S_BO_TLOP_DESCR INDEX 1 INTO DATA(WA_EAMS_S_BO_TLOP_DESCR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAMS_S_BO_TLOP_DESCR ASSIGNING <EAMS_S_BO_TLOP_DESCR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMS_S_BO_TLOP_DESCR>-CONTROL_KEY_TXT = 1.
<EAMS_S_BO_TLOP_DESCR>-PLANT_TXT = 1.
<EAMS_S_BO_TLOP_DESCR>-MEASUREMENT_UNIT_TXT = 1.
<EAMS_S_BO_TLOP_DESCR>-WAGE_TYPE_TXT = 1.
<EAMS_S_BO_TLOP_DESCR>-SUITABILITY_TXT = 1.
ENDLOOP.

LOOP AT IT_EAMS_S_BO_TLOP_DESCR INTO WA_EAMS_S_BO_TLOP_DESCR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAMS_S_BO_TLOP_DESCR-WAGE_GROUP_TXT, sy-vline,
WA_EAMS_S_BO_TLOP_DESCR-PURCH_GROUP_TXT, sy-vline,
WA_EAMS_S_BO_TLOP_DESCR-ACTIVITY_TYPE_TXT, sy-vline,
WA_EAMS_S_BO_TLOP_DESCR-SYSTEM_CONDITION_TXT, sy-vline,
WA_EAMS_S_BO_TLOP_DESCR-ASSEMBLY_TXT, sy-vline,
WA_EAMS_S_BO_TLOP_DESCR-CAPREQ_DISTR_KEY_TXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMS_S_BO_TLOP_DESCR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMS_S_BO_TLOP_DESCR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMS_S_BO_TLOP_DESCR INTO WA_EAMS_S_BO_TLOP_DESCR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMS_S_BO_TLOP_DESCR_STR,
CONTROL_KEY_TXT TYPE STRING,
PLANT_TXT TYPE STRING,
MEASUREMENT_UNIT_TXT TYPE STRING,
WAGE_TYPE_TXT TYPE STRING,
SUITABILITY_TXT TYPE STRING,
WAGE_GROUP_TXT TYPE STRING,
PURCH_GROUP_TXT TYPE STRING,
ACTIVITY_TYPE_TXT TYPE STRING,
SYSTEM_CONDITION_TXT TYPE STRING,
ASSEMBLY_TXT TYPE STRING,
CAPREQ_DISTR_KEY_TXT TYPE STRING,
OPER_ORDER_QUAN_UNIT_TXT TYPE STRING,
MAINT_WORK_CENTER_TXT TYPE STRING,
FUNCTIONAL_LOCATION_TXT TYPE STRING,
EQUIPMENT_TXT TYPE STRING,
PURCH_ORG_TXT TYPE STRING,
DURATION_UNIT_TXT TYPE STRING,
USR00_TXT TYPE STRING,
USR01_TXT TYPE STRING,
USR02_TXT TYPE STRING,
USR03_TXT TYPE STRING,
USR04_TXT TYPE STRING,
USR05_TXT TYPE STRING,
USR06_TXT TYPE STRING,
USR07_TXT TYPE STRING,
USR08_TXT TYPE STRING,
USR09_TXT TYPE STRING,
USR10_TXT TYPE STRING,
USR11_TXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMS_S_BO_TLOP_DESCR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-CONTROL_KEY_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-PLANT_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-MEASUREMENT_UNIT_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-WAGE_TYPE_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-SUITABILITY_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-WAGE_GROUP_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-PURCH_GROUP_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-ACTIVITY_TYPE_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-SYSTEM_CONDITION_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-ASSEMBLY_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-CAPREQ_DISTR_KEY_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-OPER_ORDER_QUAN_UNIT_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-MAINT_WORK_CENTER_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-FUNCTIONAL_LOCATION_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-EQUIPMENT_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-PURCH_ORG_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-DURATION_UNIT_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR00_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR01_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR02_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR03_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR04_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR05_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR06_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR07_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR08_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR09_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR10_TXT sy-vline
WA_EAMS_S_BO_TLOP_DESCR_STR-USR11_TXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.