ABAP Select data from SAP table EAMI_SMDS_DEV_COMP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAMI_SMDS_DEV_COMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAMI_SMDS_DEV_COMP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAMI_SMDS_DEV_COMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAMI_SMDS_DEV_COMP TYPE STANDARD TABLE OF EAMI_SMDS_DEV_COMP,
      WA_EAMI_SMDS_DEV_COMP TYPE EAMI_SMDS_DEV_COMP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAMI_SMDS_DEV_COMP> TYPE EAMI_SMDS_DEV_COMP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAMI_SMDS_DEV_COMP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAMI_SMDS_DEV_COMP
  INTO TABLE IT_EAMI_SMDS_DEV_COMP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAMI_SMDS_DEV_COMP
*  INTO TABLE @DATA(IT_EAMI_SMDS_DEV_COMP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAMI_SMDS_DEV_COMP INDEX 1 INTO DATA(WA_EAMI_SMDS_DEV_COMP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAMI_SMDS_DEV_COMP ASSIGNING <EAMI_SMDS_DEV_COMP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAMI_SMDS_DEV_COMP>-EQUNREGR = 1.
<EAMI_SMDS_DEV_COMP>-BISEGR = 1.
<EAMI_SMDS_DEV_COMP>-ABEGR = 1.
<EAMI_SMDS_DEV_COMP>-GERAETEGR = 1.
<EAMI_SMDS_DEV_COMP>-MATNREGR = 1.
ENDLOOP.

LOOP AT IT_EAMI_SMDS_DEV_COMP INTO WA_EAMI_SMDS_DEV_COMP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAMI_SMDS_DEV_COMP-UIIEGR, sy-vline,
WA_EAMI_SMDS_DEV_COMP-HERSTEGR, sy-vline,
WA_EAMI_SMDS_DEV_COMP-ZWGRUPPEEGR, sy-vline,
WA_EAMI_SMDS_DEV_COMP-LOGIKNREGR, sy-vline,
WA_EAMI_SMDS_DEV_COMP-DEVLOCEGR, sy-vline,
WA_EAMI_SMDS_DEV_COMP-AMSEGR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAMI_SMDS_DEV_COMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAMI_SMDS_DEV_COMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAMI_SMDS_DEV_COMP INTO WA_EAMI_SMDS_DEV_COMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EQUNREGR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMI_SMDS_DEV_COMP-EQUNREGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMI_SMDS_DEV_COMP-EQUNREGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field GERAETEGR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EAMI_SMDS_DEV_COMP-GERAETEGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMI_SMDS_DEV_COMP-GERAETEGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNREGR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAMI_SMDS_DEV_COMP-MATNREGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMI_SMDS_DEV_COMP-MATNREGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ZWGRUPPEEGR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMI_SMDS_DEV_COMP-ZWGRUPPEEGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMI_SMDS_DEV_COMP-ZWGRUPPEEGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field DEVLOCEGR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EAMI_SMDS_DEV_COMP-DEVLOCEGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMI_SMDS_DEV_COMP-DEVLOCEGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNRETZ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMI_SMDS_DEV_COMP-EQUNRETZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMI_SMDS_DEV_COMP-EQUNRETZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MASSREADETZ CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAMI_SMDS_DEV_COMP-MASSREADETZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMI_SMDS_DEV_COMP-MASSREADETZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLAGEEAS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAMI_SMDS_DEV_COMP-ANLAGEEAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAMI_SMDS_DEV_COMP-ANLAGEEAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAMI_SMDS_DEV_COMP_STR,
EQUNREGR TYPE STRING,
BISEGR TYPE STRING,
ABEGR TYPE STRING,
GERAETEGR TYPE STRING,
MATNREGR TYPE STRING,
UIIEGR TYPE STRING,
HERSTEGR TYPE STRING,
ZWGRUPPEEGR TYPE STRING,
LOGIKNREGR TYPE STRING,
DEVLOCEGR TYPE STRING,
AMSEGR TYPE STRING,
AMCG_CAP_GRPEGR TYPE STRING,
CAP_ACT_GRPEGR TYPE STRING,
EQUNRETZ TYPE STRING,
ZWNUMMERETZ TYPE STRING,
BISETZ TYPE STRING,
ABETZ TYPE STRING,
LOGIKZWETZ TYPE STRING,
KENNZIFFETZ TYPE STRING,
ZWTYPETZ TYPE STRING,
TOUPERIODETZ TYPE STRING,
MASSREADETZ TYPE STRING,
STANZVORETZ TYPE STRING,
STANZNACETZ TYPE STRING,
ZWFAKTETZ TYPE STRING,
VEE_CODEETZ TYPE STRING,
LOGIKNREZG TYPE STRING,
BISEZG TYPE STRING,
ZUARTEZG TYPE STRING,
LOGIKNR2EZG TYPE STRING,
ABEZG TYPE STRING,
LOGIKZWEZZ TYPE STRING,
BISEZZ TYPE STRING,
ZUARTEZZ TYPE STRING,
LOGIKNR2EZZ TYPE STRING,
ABEZZ TYPE STRING,
ABRFAKTEZZ TYPE STRING,
INT_UIEUI TYPE STRING,
DATETOEUI TYPE STRING,
TIMETOEUI TYPE STRING,
DATEFROMEUI TYPE STRING,
TIMEFROMEUI TYPE STRING,
EXT_UIEUI TYPE STRING,
SERGEITO TYPE STRING,
MAPARITO TYPE STRING,
ANLAGEEAS TYPE STRING,
LOGIKZWEAS TYPE STRING,
BISEAS TYPE STRING,
ABEAS TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAMI_SMDS_DEV_COMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-EQUNREGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-BISEGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ABEGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-GERAETEGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-MATNREGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-UIIEGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-HERSTEGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ZWGRUPPEEGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-LOGIKNREGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-DEVLOCEGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-AMSEGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-AMCG_CAP_GRPEGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-CAP_ACT_GRPEGR sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-EQUNRETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ZWNUMMERETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-BISETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ABETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-LOGIKZWETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-KENNZIFFETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ZWTYPETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-TOUPERIODETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-MASSREADETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-STANZVORETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-STANZNACETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ZWFAKTETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-VEE_CODEETZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-LOGIKNREZG sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-BISEZG sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ZUARTEZG sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-LOGIKNR2EZG sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ABEZG sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-LOGIKZWEZZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-BISEZZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ZUARTEZZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-LOGIKNR2EZZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ABEZZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ABRFAKTEZZ sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-INT_UIEUI sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-DATETOEUI sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-TIMETOEUI sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-DATEFROMEUI sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-TIMEFROMEUI sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-EXT_UIEUI sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-SERGEITO sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-MAPARITO sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ANLAGEEAS sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-LOGIKZWEAS sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-BISEAS sy-vline
WA_EAMI_SMDS_DEV_COMP_STR-ABEAS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.