ABAP Select data from SAP table EAM_S_TL_OPR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EAM_S_TL_OPR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EAM_S_TL_OPR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EAM_S_TL_OPR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EAM_S_TL_OPR TYPE STANDARD TABLE OF EAM_S_TL_OPR,
      WA_EAM_S_TL_OPR TYPE EAM_S_TL_OPR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EAM_S_TL_OPR> TYPE EAM_S_TL_OPR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EAM_S_TL_OPR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EAM_S_TL_OPR
  INTO TABLE IT_EAM_S_TL_OPR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EAM_S_TL_OPR
*  INTO TABLE @DATA(IT_EAM_S_TL_OPR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EAM_S_TL_OPR INDEX 1 INTO DATA(WA_EAM_S_TL_OPR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EAM_S_TL_OPR ASSIGNING <EAM_S_TL_OPR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EAM_S_TL_OPR>-PLNTY = 1.
<EAM_S_TL_OPR>-PLNNR = 1.
<EAM_S_TL_OPR>-PLNAL = 1.
<EAM_S_TL_OPR>-PLNKN = 1.
<EAM_S_TL_OPR>-VORNR = 1.
ENDLOOP.

LOOP AT IT_EAM_S_TL_OPR INTO WA_EAM_S_TL_OPR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EAM_S_TL_OPR-UVORN, sy-vline,
WA_EAM_S_TL_OPR-STEUS, sy-vline,
WA_EAM_S_TL_OPR-ARBPL, sy-vline,
WA_EAM_S_TL_OPR-WERKS, sy-vline,
WA_EAM_S_TL_OPR-KTSCH, sy-vline,
WA_EAM_S_TL_OPR-LTXA1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EAM_S_TL_OPR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EAM_S_TL_OPR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EAM_S_TL_OPR INTO WA_EAM_S_TL_OPR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field UVORN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-UVORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-UVORN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TXTSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-TXTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-TXTSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BMEIH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-BMEIH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-BMEIH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SAKTO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-SAKTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-SAKTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-INFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-INFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ISTRU CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-ISTRU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-ISTRU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DAUNE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-DAUNE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-DAUNE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ARBEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-ARBEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-ARBEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-USE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-USE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-USE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-USE05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-EHOFFB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-EHOFFB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-EHOFFE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-EHOFFE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUBPLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-SUBPLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-SUBPLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUBPLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-SUBPLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-SUBPLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MOEPC, internal->external for field EXECUTION_STAGE CALL FUNCTION 'CONVERSION_EXIT_MOEPC_OUTPUT' EXPORTING input = WA_EAM_S_TL_OPR-EXECUTION_STAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EAM_S_TL_OPR-EXECUTION_STAGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EAM_S_TL_OPR_STR,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNAL TYPE STRING,
PLNKN TYPE STRING,
VORNR TYPE STRING,
UVORN TYPE STRING,
STEUS TYPE STRING,
ARBPL TYPE STRING,
WERKS TYPE STRING,
KTSCH TYPE STRING,
LTXA1 TYPE STRING,
TXTSP TYPE STRING,
LOANZ TYPE STRING,
LOART TYPE STRING,
QUALF TYPE STRING,
LOGRP TYPE STRING,
SORTL TYPE STRING,
LIFNR TYPE STRING,
BMEIH TYPE STRING,
BMVRG TYPE STRING,
PREIS TYPE STRING,
PEINH TYPE STRING,
SAKTO TYPE STRING,
WAERS TYPE STRING,
INFNR TYPE STRING,
EKORG TYPE STRING,
EKGRP TYPE STRING,
MATKL TYPE STRING,
ANZZL TYPE STRING,
PRZNT TYPE STRING,
INDET TYPE STRING,
LARNT TYPE STRING,
ANLZU TYPE STRING,
ISTRU TYPE STRING,
VERTL TYPE STRING,
PLIFZ TYPE STRING,
DAUNO TYPE STRING,
DAUNE TYPE STRING,
EINSA TYPE STRING,
EINSE TYPE STRING,
ARBEI TYPE STRING,
ARBEH TYPE STRING,
SLWID TYPE STRING,
AUFKT TYPE STRING,
USR00 TYPE STRING,
USR01 TYPE STRING,
USR02 TYPE STRING,
USR03 TYPE STRING,
USR04 TYPE STRING,
USE04 TYPE STRING,
USR05 TYPE STRING,
USE05 TYPE STRING,
USR06 TYPE STRING,
USE06 TYPE STRING,
USR07 TYPE STRING,
USE07 TYPE STRING,
USR08 TYPE STRING,
USR09 TYPE STRING,
USR10 TYPE STRING,
USR11 TYPE STRING,
OFFSTB TYPE STRING,
EHOFFB TYPE STRING,
OFFSTE TYPE STRING,
EHOFFE TYPE STRING,
EQUNR TYPE STRING,
TPLNR TYPE STRING,
EBELP TYPE STRING,
EBELN TYPE STRING,
LTXA2 TYPE STRING,
SUMNR TYPE STRING,
SUBPLNTY TYPE STRING,
SUBPLNNR TYPE STRING,
SUBPLNAL TYPE STRING,
XEXCLTL TYPE STRING,
PACKNO TYPE STRING,
EXECUTION_STAGE TYPE STRING,
CL_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_EAM_S_TL_OPR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EAM_S_TL_OPR_STR-PLNTY sy-vline
WA_EAM_S_TL_OPR_STR-PLNNR sy-vline
WA_EAM_S_TL_OPR_STR-PLNAL sy-vline
WA_EAM_S_TL_OPR_STR-PLNKN sy-vline
WA_EAM_S_TL_OPR_STR-VORNR sy-vline
WA_EAM_S_TL_OPR_STR-UVORN sy-vline
WA_EAM_S_TL_OPR_STR-STEUS sy-vline
WA_EAM_S_TL_OPR_STR-ARBPL sy-vline
WA_EAM_S_TL_OPR_STR-WERKS sy-vline
WA_EAM_S_TL_OPR_STR-KTSCH sy-vline
WA_EAM_S_TL_OPR_STR-LTXA1 sy-vline
WA_EAM_S_TL_OPR_STR-TXTSP sy-vline
WA_EAM_S_TL_OPR_STR-LOANZ sy-vline
WA_EAM_S_TL_OPR_STR-LOART sy-vline
WA_EAM_S_TL_OPR_STR-QUALF sy-vline
WA_EAM_S_TL_OPR_STR-LOGRP sy-vline
WA_EAM_S_TL_OPR_STR-SORTL sy-vline
WA_EAM_S_TL_OPR_STR-LIFNR sy-vline
WA_EAM_S_TL_OPR_STR-BMEIH sy-vline
WA_EAM_S_TL_OPR_STR-BMVRG sy-vline
WA_EAM_S_TL_OPR_STR-PREIS sy-vline
WA_EAM_S_TL_OPR_STR-PEINH sy-vline
WA_EAM_S_TL_OPR_STR-SAKTO sy-vline
WA_EAM_S_TL_OPR_STR-WAERS sy-vline
WA_EAM_S_TL_OPR_STR-INFNR sy-vline
WA_EAM_S_TL_OPR_STR-EKORG sy-vline
WA_EAM_S_TL_OPR_STR-EKGRP sy-vline
WA_EAM_S_TL_OPR_STR-MATKL sy-vline
WA_EAM_S_TL_OPR_STR-ANZZL sy-vline
WA_EAM_S_TL_OPR_STR-PRZNT sy-vline
WA_EAM_S_TL_OPR_STR-INDET sy-vline
WA_EAM_S_TL_OPR_STR-LARNT sy-vline
WA_EAM_S_TL_OPR_STR-ANLZU sy-vline
WA_EAM_S_TL_OPR_STR-ISTRU sy-vline
WA_EAM_S_TL_OPR_STR-VERTL sy-vline
WA_EAM_S_TL_OPR_STR-PLIFZ sy-vline
WA_EAM_S_TL_OPR_STR-DAUNO sy-vline
WA_EAM_S_TL_OPR_STR-DAUNE sy-vline
WA_EAM_S_TL_OPR_STR-EINSA sy-vline
WA_EAM_S_TL_OPR_STR-EINSE sy-vline
WA_EAM_S_TL_OPR_STR-ARBEI sy-vline
WA_EAM_S_TL_OPR_STR-ARBEH sy-vline
WA_EAM_S_TL_OPR_STR-SLWID sy-vline
WA_EAM_S_TL_OPR_STR-AUFKT sy-vline
WA_EAM_S_TL_OPR_STR-USR00 sy-vline
WA_EAM_S_TL_OPR_STR-USR01 sy-vline
WA_EAM_S_TL_OPR_STR-USR02 sy-vline
WA_EAM_S_TL_OPR_STR-USR03 sy-vline
WA_EAM_S_TL_OPR_STR-USR04 sy-vline
WA_EAM_S_TL_OPR_STR-USE04 sy-vline
WA_EAM_S_TL_OPR_STR-USR05 sy-vline
WA_EAM_S_TL_OPR_STR-USE05 sy-vline
WA_EAM_S_TL_OPR_STR-USR06 sy-vline
WA_EAM_S_TL_OPR_STR-USE06 sy-vline
WA_EAM_S_TL_OPR_STR-USR07 sy-vline
WA_EAM_S_TL_OPR_STR-USE07 sy-vline
WA_EAM_S_TL_OPR_STR-USR08 sy-vline
WA_EAM_S_TL_OPR_STR-USR09 sy-vline
WA_EAM_S_TL_OPR_STR-USR10 sy-vline
WA_EAM_S_TL_OPR_STR-USR11 sy-vline
WA_EAM_S_TL_OPR_STR-OFFSTB sy-vline
WA_EAM_S_TL_OPR_STR-EHOFFB sy-vline
WA_EAM_S_TL_OPR_STR-OFFSTE sy-vline
WA_EAM_S_TL_OPR_STR-EHOFFE sy-vline
WA_EAM_S_TL_OPR_STR-EQUNR sy-vline
WA_EAM_S_TL_OPR_STR-TPLNR sy-vline
WA_EAM_S_TL_OPR_STR-EBELP sy-vline
WA_EAM_S_TL_OPR_STR-EBELN sy-vline
WA_EAM_S_TL_OPR_STR-LTXA2 sy-vline
WA_EAM_S_TL_OPR_STR-SUMNR sy-vline
WA_EAM_S_TL_OPR_STR-SUBPLNTY sy-vline
WA_EAM_S_TL_OPR_STR-SUBPLNNR sy-vline
WA_EAM_S_TL_OPR_STR-SUBPLNAL sy-vline
WA_EAM_S_TL_OPR_STR-XEXCLTL sy-vline
WA_EAM_S_TL_OPR_STR-PACKNO sy-vline
WA_EAM_S_TL_OPR_STR-EXECUTION_STAGE sy-vline
WA_EAM_S_TL_OPR_STR-CL_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.