ABAP Select data from SAP table E3TPTRP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E3TPTRP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E3TPTRP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E3TPTRP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E3TPTRP TYPE STANDARD TABLE OF E3TPTRP,
      WA_E3TPTRP TYPE E3TPTRP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E3TPTRP> TYPE E3TPTRP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E3TPTRP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E3TPTRP
  INTO TABLE IT_E3TPTRP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E3TPTRP
*  INTO TABLE @DATA(IT_E3TPTRP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E3TPTRP INDEX 1 INTO DATA(WA_E3TPTRP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E3TPTRP ASSIGNING <E3TPTRP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E3TPTRP>-SHPPPT = 1.
<E3TPTRP>-SHPID = 1.
<E3TPTRP>-SHPTYP = 1.
<E3TPTRP>-LEGIND = 1.
<E3TPTRP>-LOCCL1 = 1.
ENDLOOP.

LOOP AT IT_E3TPTRP INTO WA_E3TPTRP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E3TPTRP-LOCID1, sy-vline,
WA_E3TPTRP-SUBID1, sy-vline,
WA_E3TPTRP-ADRNR1, sy-vline,
WA_E3TPTRP-LOCCL2, sy-vline,
WA_E3TPTRP-LOCID2, sy-vline,
WA_E3TPTRP-SUBID2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E3TPTRP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E3TPTRP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E3TPTRP INTO WA_E3TPTRP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SHPID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3TPTRP-SHPID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3TPTRP-SHPID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNR1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3TPTRP-ADRNR1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3TPTRP-ADRNR1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNR2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3TPTRP-ADRNR2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3TPTRP-ADRNR2.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E3TPTRP_STR,
SHPPPT TYPE STRING,
SHPID TYPE STRING,
SHPTYP TYPE STRING,
LEGIND TYPE STRING,
LOCCL1 TYPE STRING,
LOCID1 TYPE STRING,
SUBID1 TYPE STRING,
ADRNR1 TYPE STRING,
LOCCL2 TYPE STRING,
LOCID2 TYPE STRING,
SUBID2 TYPE STRING,
ADRNR2 TYPE STRING,
DATBEG TYPE STRING,
TIMBEG TYPE STRING,
TZONBG TYPE STRING,
DATEND TYPE STRING,
TIMEND TYPE STRING,
TZONEN TYPE STRING,END OF T_EKKO_STR. DATA: WA_E3TPTRP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E3TPTRP_STR-SHPPPT sy-vline
WA_E3TPTRP_STR-SHPID sy-vline
WA_E3TPTRP_STR-SHPTYP sy-vline
WA_E3TPTRP_STR-LEGIND sy-vline
WA_E3TPTRP_STR-LOCCL1 sy-vline
WA_E3TPTRP_STR-LOCID1 sy-vline
WA_E3TPTRP_STR-SUBID1 sy-vline
WA_E3TPTRP_STR-ADRNR1 sy-vline
WA_E3TPTRP_STR-LOCCL2 sy-vline
WA_E3TPTRP_STR-LOCID2 sy-vline
WA_E3TPTRP_STR-SUBID2 sy-vline
WA_E3TPTRP_STR-ADRNR2 sy-vline
WA_E3TPTRP_STR-DATBEG sy-vline
WA_E3TPTRP_STR-TIMBEG sy-vline
WA_E3TPTRP_STR-TZONBG sy-vline
WA_E3TPTRP_STR-DATEND sy-vline
WA_E3TPTRP_STR-TIMEND sy-vline
WA_E3TPTRP_STR-TZONEN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.