ABAP Select data from SAP table E3OILS3 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E3OILS3 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E3OILS3. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E3OILS3 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E3OILS3 TYPE STANDARD TABLE OF E3OILS3,
      WA_E3OILS3 TYPE E3OILS3,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E3OILS3> TYPE E3OILS3.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E3OILS3.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E3OILS3
  INTO TABLE IT_E3OILS3.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E3OILS3
*  INTO TABLE @DATA(IT_E3OILS32).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E3OILS3 INDEX 1 INTO DATA(WA_E3OILS32).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E3OILS3 ASSIGNING <E3OILS3>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E3OILS3>-MAT_ITM = 1.
<E3OILS3>-LABST = 1.
<E3OILS3>-GLQTY = 1.
<E3OILS3>-RSNCDV = 1.
<E3OILS3>-MBLNR = 1.
ENDLOOP.

LOOP AT IT_E3OILS3 INTO WA_E3OILS3.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E3OILS3-MJAHR, sy-vline,
WA_E3OILS3-ZEILE, sy-vline,
WA_E3OILS3-LABST_P, sy-vline,
WA_E3OILS3-GLQTY_P, sy-vline,
WA_E3OILS3-UPDATEFLAG, sy-vline,
WA_E3OILS3-REAS_CODED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E3OILS3 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E3OILS3 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E3OILS3 INTO WA_E3OILS3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field MBLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3OILS3-MBLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILS3-MBLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field MJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_E3OILS3-MJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILS3-MJAHR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E3OILS3_STR,
MAT_ITM TYPE STRING,
LABST TYPE STRING,
GLQTY TYPE STRING,
RSNCDV TYPE STRING,
MBLNR TYPE STRING,
MJAHR TYPE STRING,
ZEILE TYPE STRING,
LABST_P TYPE STRING,
GLQTY_P TYPE STRING,
UPDATEFLAG TYPE STRING,
REAS_CODED TYPE STRING,END OF T_EKKO_STR. DATA: WA_E3OILS3_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E3OILS3_STR-MAT_ITM sy-vline
WA_E3OILS3_STR-LABST sy-vline
WA_E3OILS3_STR-GLQTY sy-vline
WA_E3OILS3_STR-RSNCDV sy-vline
WA_E3OILS3_STR-MBLNR sy-vline
WA_E3OILS3_STR-MJAHR sy-vline
WA_E3OILS3_STR-ZEILE sy-vline
WA_E3OILS3_STR-LABST_P sy-vline
WA_E3OILS3_STR-GLQTY_P sy-vline
WA_E3OILS3_STR-UPDATEFLAG sy-vline
WA_E3OILS3_STR-REAS_CODED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.