ABAP Select data from SAP table E3OILPS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E3OILPS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E3OILPS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E3OILPS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E3OILPS TYPE STANDARD TABLE OF E3OILPS,
      WA_E3OILPS TYPE E3OILPS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E3OILPS> TYPE E3OILPS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E3OILPS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E3OILPS
  INTO TABLE IT_E3OILPS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E3OILPS
*  INTO TABLE @DATA(IT_E3OILPS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E3OILPS INDEX 1 INTO DATA(WA_E3OILPS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E3OILPS ASSIGNING <E3OILPS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E3OILPS>-SEQNR = 1.
<E3OILPS>-SOCNR = 1.
<E3OILPS>-SOCKL = 1.
<E3OILPS>-SOCTYP = 1.
<E3OILPS>-EQUNR = 1.
ENDLOOP.

LOOP AT IT_E3OILPS INTO WA_E3OILPS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E3OILPS-TPLNR, sy-vline,
WA_E3OILPS-HZEIN, sy-vline,
WA_E3OILPS-SERGE, sy-vline,
WA_E3OILPS-TYPBZ, sy-vline,
WA_E3OILPS-BAUJJ, sy-vline,
WA_E3OILPS-BAUMM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E3OILPS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E3OILPS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E3OILPS INTO WA_E3OILPS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SEQNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3OILPS-SEQNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILPS-SEQNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3OILPS-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILPS-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_E3OILPS-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILPS-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLUN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3OILPS-VOLUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILPS-VOLUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MASUN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3OILPS-MASUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILPS-MASUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LENUN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3OILPS-LENUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILPS-LENUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FRTUN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3OILPS-FRTUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILPS-FRTUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TIMUN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3OILPS-TIMUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILPS-TIMUN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TMPUN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3OILPS-TMPUN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3OILPS-TMPUN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E3OILPS_STR,
SEQNR TYPE STRING,
SOCNR TYPE STRING,
SOCKL TYPE STRING,
SOCTYP TYPE STRING,
EQUNR TYPE STRING,
TPLNR TYPE STRING,
HZEIN TYPE STRING,
SERGE TYPE STRING,
TYPBZ TYPE STRING,
BAUJJ TYPE STRING,
BAUMM TYPE STRING,
VOLUN TYPE STRING,
MASUN TYPE STRING,
LENUN TYPE STRING,
FRTUN TYPE STRING,
TIMUN TYPE STRING,
TMPUN TYPE STRING,
KAPAZ TYPE STRING,
MXMAS TYPE STRING,
GXDAT TYPE STRING,
GXTIM TYPE STRING,
GXREA TYPE STRING,
SOGRP TYPE STRING,
SLVNR TYPE STRING,
MAXDP TYPE STRING,
MINDP TYPE STRING,
MAXIN TYPE STRING,
MAXOUT TYPE STRING,
UNPKZ TYPE STRING,
UNPPC TYPE STRING,
WASKZ TYPE STRING,
WASPC TYPE STRING,
FLMAS TYPE STRING,
GFLAG TYPE STRING,
HFLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E3OILPS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E3OILPS_STR-SEQNR sy-vline
WA_E3OILPS_STR-SOCNR sy-vline
WA_E3OILPS_STR-SOCKL sy-vline
WA_E3OILPS_STR-SOCTYP sy-vline
WA_E3OILPS_STR-EQUNR sy-vline
WA_E3OILPS_STR-TPLNR sy-vline
WA_E3OILPS_STR-HZEIN sy-vline
WA_E3OILPS_STR-SERGE sy-vline
WA_E3OILPS_STR-TYPBZ sy-vline
WA_E3OILPS_STR-BAUJJ sy-vline
WA_E3OILPS_STR-BAUMM sy-vline
WA_E3OILPS_STR-VOLUN sy-vline
WA_E3OILPS_STR-MASUN sy-vline
WA_E3OILPS_STR-LENUN sy-vline
WA_E3OILPS_STR-FRTUN sy-vline
WA_E3OILPS_STR-TIMUN sy-vline
WA_E3OILPS_STR-TMPUN sy-vline
WA_E3OILPS_STR-KAPAZ sy-vline
WA_E3OILPS_STR-MXMAS sy-vline
WA_E3OILPS_STR-GXDAT sy-vline
WA_E3OILPS_STR-GXTIM sy-vline
WA_E3OILPS_STR-GXREA sy-vline
WA_E3OILPS_STR-SOGRP sy-vline
WA_E3OILPS_STR-SLVNR sy-vline
WA_E3OILPS_STR-MAXDP sy-vline
WA_E3OILPS_STR-MINDP sy-vline
WA_E3OILPS_STR-MAXIN sy-vline
WA_E3OILPS_STR-MAXOUT sy-vline
WA_E3OILPS_STR-UNPKZ sy-vline
WA_E3OILPS_STR-UNPPC sy-vline
WA_E3OILPS_STR-WASKZ sy-vline
WA_E3OILPS_STR-WASPC sy-vline
WA_E3OILPS_STR-FLMAS sy-vline
WA_E3OILPS_STR-GFLAG sy-vline
WA_E3OILPS_STR-HFLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.