ABAP Select data from SAP table E3EDP10 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E3EDP10 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E3EDP10. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E3EDP10 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E3EDP10 TYPE STANDARD TABLE OF E3EDP10,
      WA_E3EDP10 TYPE E3EDP10,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E3EDP10> TYPE E3EDP10.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E3EDP10.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E3EDP10
  INTO TABLE IT_E3EDP10.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E3EDP10
*  INTO TABLE @DATA(IT_E3EDP102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E3EDP10 INDEX 1 INTO DATA(WA_E3EDP102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E3EDP10 ASSIGNING <E3EDP10>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E3EDP10>-IDNKD = 1.
<E3EDP10>-ARKTX = 1.
<E3EDP10>-VRKME = 1.
<E3EDP10>-KWERK = 1.
<E3EDP10>-KLGOR = 1.
ENDLOOP.

LOOP AT IT_E3EDP10 INTO WA_E3EDP10.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E3EDP10-DFABL, sy-vline,
WA_E3EDP10-VBRST, sy-vline,
WA_E3EDP10-BELNR, sy-vline,
WA_E3EDP10-LFIMG, sy-vline,
WA_E3EDP10-VEMNG, sy-vline,
WA_E3EDP10-LIDTL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E3EDP10 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E3EDP10 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E3EDP10 INTO WA_E3EDP10. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field VRKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3EDP10-VRKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDP10-VRKME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E3EDP10_STR,
IDNKD TYPE STRING,
ARKTX TYPE STRING,
VRKME TYPE STRING,
KWERK TYPE STRING,
KLGOR TYPE STRING,
DFABL TYPE STRING,
VBRST TYPE STRING,
BELNR TYPE STRING,
LFIMG TYPE STRING,
VEMNG TYPE STRING,
LIDTL TYPE STRING,
LIFST TYPE STRING,
KRITB TYPE STRING,
ABHOR TYPE STRING,
ABDAT TYPE STRING,
FZDIF TYPE STRING,
AKUBM TYPE STRING,
AKUEM TYPE STRING,
DESRE TYPE STRING,
ECHNO TYPE STRING,
ECHDT TYPE STRING,
ABFDE TYPE STRING,
MFADT TYPE STRING,
ABMDE TYPE STRING,
FPSDN TYPE STRING,
LABKY TYPE STRING,
TSTKY TYPE STRING,
DOKPF TYPE STRING,
KZAUS TYPE STRING,
ABRAB TYPE STRING,
ABRBI TYPE STRING,
SCREL TYPE STRING,
NULDT TYPE STRING,
TEART TYPE STRING,
SOLLFZ TYPE STRING,
SOLLDT TYPE STRING,
IDNLF TYPE STRING,
BSTDK TYPE STRING,
LABNK TYPE STRING,
ABNRA TYPE STRING,
ABNRD TYPE STRING,
VTRNR TYPE STRING,
MFRFZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_E3EDP10_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E3EDP10_STR-IDNKD sy-vline
WA_E3EDP10_STR-ARKTX sy-vline
WA_E3EDP10_STR-VRKME sy-vline
WA_E3EDP10_STR-KWERK sy-vline
WA_E3EDP10_STR-KLGOR sy-vline
WA_E3EDP10_STR-DFABL sy-vline
WA_E3EDP10_STR-VBRST sy-vline
WA_E3EDP10_STR-BELNR sy-vline
WA_E3EDP10_STR-LFIMG sy-vline
WA_E3EDP10_STR-VEMNG sy-vline
WA_E3EDP10_STR-LIDTL sy-vline
WA_E3EDP10_STR-LIFST sy-vline
WA_E3EDP10_STR-KRITB sy-vline
WA_E3EDP10_STR-ABHOR sy-vline
WA_E3EDP10_STR-ABDAT sy-vline
WA_E3EDP10_STR-FZDIF sy-vline
WA_E3EDP10_STR-AKUBM sy-vline
WA_E3EDP10_STR-AKUEM sy-vline
WA_E3EDP10_STR-DESRE sy-vline
WA_E3EDP10_STR-ECHNO sy-vline
WA_E3EDP10_STR-ECHDT sy-vline
WA_E3EDP10_STR-ABFDE sy-vline
WA_E3EDP10_STR-MFADT sy-vline
WA_E3EDP10_STR-ABMDE sy-vline
WA_E3EDP10_STR-FPSDN sy-vline
WA_E3EDP10_STR-LABKY sy-vline
WA_E3EDP10_STR-TSTKY sy-vline
WA_E3EDP10_STR-DOKPF sy-vline
WA_E3EDP10_STR-KZAUS sy-vline
WA_E3EDP10_STR-ABRAB sy-vline
WA_E3EDP10_STR-ABRBI sy-vline
WA_E3EDP10_STR-SCREL sy-vline
WA_E3EDP10_STR-NULDT sy-vline
WA_E3EDP10_STR-TEART sy-vline
WA_E3EDP10_STR-SOLLFZ sy-vline
WA_E3EDP10_STR-SOLLDT sy-vline
WA_E3EDP10_STR-IDNLF sy-vline
WA_E3EDP10_STR-BSTDK sy-vline
WA_E3EDP10_STR-LABNK sy-vline
WA_E3EDP10_STR-ABNRA sy-vline
WA_E3EDP10_STR-ABNRD sy-vline
WA_E3EDP10_STR-VTRNR sy-vline
WA_E3EDP10_STR-MFRFZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.