ABAP Select data from SAP table E3EDL33 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E3EDL33 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E3EDL33. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E3EDL33 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E3EDL33 TYPE STANDARD TABLE OF E3EDL33,
      WA_E3EDL33 TYPE E3EDL33,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E3EDL33> TYPE E3EDL33.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E3EDL33.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E3EDL33
  INTO TABLE IT_E3EDL33.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E3EDL33
*  INTO TABLE @DATA(IT_E3EDL332).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E3EDL33 INDEX 1 INTO DATA(WA_E3EDL332).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E3EDL33 ASSIGNING <E3EDL33>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E3EDL33>-ALAND = 1.
<E3EDL33>-EXPVZ = 1.
<E3EDL33>-ZOLLA = 1.
<E3EDL33>-ZOLLB = 1.
<E3EDL33>-ZOLL1 = 1.
ENDLOOP.

LOOP AT IT_E3EDL33 INTO WA_E3EDL33.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E3EDL33-ZOLL2, sy-vline,
WA_E3EDL33-ZOLL3, sy-vline,
WA_E3EDL33-ZOLL4, sy-vline,
WA_E3EDL33-ZOLL5, sy-vline,
WA_E3EDL33-ZOLL6, sy-vline,
WA_E3EDL33-KZGBE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E3EDL33 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E3EDL33 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E3EDL33 INTO WA_E3EDL33. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E3EDL33_STR,
ALAND TYPE STRING,
EXPVZ TYPE STRING,
ZOLLA TYPE STRING,
ZOLLB TYPE STRING,
ZOLL1 TYPE STRING,
ZOLL2 TYPE STRING,
ZOLL3 TYPE STRING,
ZOLL4 TYPE STRING,
ZOLL5 TYPE STRING,
ZOLL6 TYPE STRING,
KZGBE TYPE STRING,
KZABE TYPE STRING,
STGBE TYPE STRING,
STABE TYPE STRING,
CONTA TYPE STRING,
GRWCU TYPE STRING,
IEVER TYPE STRING,END OF T_EKKO_STR. DATA: WA_E3EDL33_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E3EDL33_STR-ALAND sy-vline
WA_E3EDL33_STR-EXPVZ sy-vline
WA_E3EDL33_STR-ZOLLA sy-vline
WA_E3EDL33_STR-ZOLLB sy-vline
WA_E3EDL33_STR-ZOLL1 sy-vline
WA_E3EDL33_STR-ZOLL2 sy-vline
WA_E3EDL33_STR-ZOLL3 sy-vline
WA_E3EDL33_STR-ZOLL4 sy-vline
WA_E3EDL33_STR-ZOLL5 sy-vline
WA_E3EDL33_STR-ZOLL6 sy-vline
WA_E3EDL33_STR-KZGBE sy-vline
WA_E3EDL33_STR-KZABE sy-vline
WA_E3EDL33_STR-STGBE sy-vline
WA_E3EDL33_STR-STABE sy-vline
WA_E3EDL33_STR-CONTA sy-vline
WA_E3EDL33_STR-GRWCU sy-vline
WA_E3EDL33_STR-IEVER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.