ABAP Select data from SAP table E3EDL07 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E3EDL07 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E3EDL07. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E3EDL07 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E3EDL07 TYPE STANDARD TABLE OF E3EDL07,
      WA_E3EDL07 TYPE E3EDL07,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E3EDL07> TYPE E3EDL07.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E3EDL07.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E3EDL07
  INTO TABLE IT_E3EDL07.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E3EDL07
*  INTO TABLE @DATA(IT_E3EDL072).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E3EDL07 INDEX 1 INTO DATA(WA_E3EDL072).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E3EDL07 ASSIGNING <E3EDL07>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E3EDL07>-VENUM = 1.
<E3EDL07>-EXIDV = 1.
<E3EDL07>-BRGEW = 1.
<E3EDL07>-NTGEW = 1.
<E3EDL07>-MAGEW = 1.
ENDLOOP.

LOOP AT IT_E3EDL07 INTO WA_E3EDL07.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E3EDL07-TARAG, sy-vline,
WA_E3EDL07-GEWEI, sy-vline,
WA_E3EDL07-BTVOL, sy-vline,
WA_E3EDL07-NTVOL, sy-vline,
WA_E3EDL07-MAVOL, sy-vline,
WA_E3EDL07-TAVOL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E3EDL07 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E3EDL07 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E3EDL07 INTO WA_E3EDL07. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VENUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3EDL07-VENUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDL07-VENUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXIDV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3EDL07-EXIDV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDL07-EXIDV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3EDL07-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDL07-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3EDL07-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDL07-VOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field VHILM CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_E3EDL07-VHILM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDL07-VHILM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEABM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3EDL07-MEABM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDL07-MEABM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LADEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3EDL07-LADEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDL07-LADEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FAREH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3EDL07-FAREH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDL07-FAREH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHENT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3EDL07-EHENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDL07-EHENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXIDV2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3EDL07-EXIDV2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3EDL07-EXIDV2.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E3EDL07_STR,
VENUM TYPE STRING,
EXIDV TYPE STRING,
BRGEW TYPE STRING,
NTGEW TYPE STRING,
MAGEW TYPE STRING,
TARAG TYPE STRING,
GEWEI TYPE STRING,
BTVOL TYPE STRING,
NTVOL TYPE STRING,
MAVOL TYPE STRING,
TAVOL TYPE STRING,
VOLEH TYPE STRING,
VEGR1 TYPE STRING,
VEGR1_BEZ TYPE STRING,
VEGR2 TYPE STRING,
VEGR2_BEZ TYPE STRING,
VEGR3 TYPE STRING,
VEGR3_BEZ TYPE STRING,
VEGR4 TYPE STRING,
VEGR4_BEZ TYPE STRING,
VEGR5 TYPE STRING,
VEGR5_BEZ TYPE STRING,
VHILM TYPE STRING,
LAENG TYPE STRING,
BREIT TYPE STRING,
HOEHE TYPE STRING,
MEABM TYPE STRING,
INHALT TYPE STRING,
VHART TYPE STRING,
VHART_BEZ TYPE STRING,
MAGRV TYPE STRING,
MAGRV_BEZ TYPE STRING,
LADLG TYPE STRING,
LADEH TYPE STRING,
FARZT TYPE STRING,
FAREH TYPE STRING,
ENTFE TYPE STRING,
EHENT TYPE STRING,
VELTP TYPE STRING,
EXIDV2 TYPE STRING,
LANDT TYPE STRING,
LANDF TYPE STRING,
NAMEF TYPE STRING,
NAMBE TYPE STRING,
VHILM_KU TYPE STRING,
VEBEZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_E3EDL07_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E3EDL07_STR-VENUM sy-vline
WA_E3EDL07_STR-EXIDV sy-vline
WA_E3EDL07_STR-BRGEW sy-vline
WA_E3EDL07_STR-NTGEW sy-vline
WA_E3EDL07_STR-MAGEW sy-vline
WA_E3EDL07_STR-TARAG sy-vline
WA_E3EDL07_STR-GEWEI sy-vline
WA_E3EDL07_STR-BTVOL sy-vline
WA_E3EDL07_STR-NTVOL sy-vline
WA_E3EDL07_STR-MAVOL sy-vline
WA_E3EDL07_STR-TAVOL sy-vline
WA_E3EDL07_STR-VOLEH sy-vline
WA_E3EDL07_STR-VEGR1 sy-vline
WA_E3EDL07_STR-VEGR1_BEZ sy-vline
WA_E3EDL07_STR-VEGR2 sy-vline
WA_E3EDL07_STR-VEGR2_BEZ sy-vline
WA_E3EDL07_STR-VEGR3 sy-vline
WA_E3EDL07_STR-VEGR3_BEZ sy-vline
WA_E3EDL07_STR-VEGR4 sy-vline
WA_E3EDL07_STR-VEGR4_BEZ sy-vline
WA_E3EDL07_STR-VEGR5 sy-vline
WA_E3EDL07_STR-VEGR5_BEZ sy-vline
WA_E3EDL07_STR-VHILM sy-vline
WA_E3EDL07_STR-LAENG sy-vline
WA_E3EDL07_STR-BREIT sy-vline
WA_E3EDL07_STR-HOEHE sy-vline
WA_E3EDL07_STR-MEABM sy-vline
WA_E3EDL07_STR-INHALT sy-vline
WA_E3EDL07_STR-VHART sy-vline
WA_E3EDL07_STR-VHART_BEZ sy-vline
WA_E3EDL07_STR-MAGRV sy-vline
WA_E3EDL07_STR-MAGRV_BEZ sy-vline
WA_E3EDL07_STR-LADLG sy-vline
WA_E3EDL07_STR-LADEH sy-vline
WA_E3EDL07_STR-FARZT sy-vline
WA_E3EDL07_STR-FAREH sy-vline
WA_E3EDL07_STR-ENTFE sy-vline
WA_E3EDL07_STR-EHENT sy-vline
WA_E3EDL07_STR-VELTP sy-vline
WA_E3EDL07_STR-EXIDV2 sy-vline
WA_E3EDL07_STR-LANDT sy-vline
WA_E3EDL07_STR-LANDF sy-vline
WA_E3EDL07_STR-NAMEF sy-vline
WA_E3EDL07_STR-NAMBE sy-vline
WA_E3EDL07_STR-VHILM_KU sy-vline
WA_E3EDL07_STR-VEBEZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.