ABAP Select data from SAP table E3CVBPA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E3CVBPA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E3CVBPA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E3CVBPA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E3CVBPA TYPE STANDARD TABLE OF E3CVBPA,
      WA_E3CVBPA TYPE E3CVBPA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E3CVBPA> TYPE E3CVBPA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E3CVBPA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E3CVBPA
  INTO TABLE IT_E3CVBPA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E3CVBPA
*  INTO TABLE @DATA(IT_E3CVBPA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E3CVBPA INDEX 1 INTO DATA(WA_E3CVBPA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E3CVBPA ASSIGNING <E3CVBPA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E3CVBPA>-SUPKZ = 1.
<E3CVBPA>-VBELN = 1.
<E3CVBPA>-POSNR = 1.
<E3CVBPA>-PARVW = 1.
<E3CVBPA>-KUNNR = 1.
ENDLOOP.

LOOP AT IT_E3CVBPA INTO WA_E3CVBPA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E3CVBPA-LIFNR, sy-vline,
WA_E3CVBPA-PERNR, sy-vline,
WA_E3CVBPA-PARNR, sy-vline,
WA_E3CVBPA-ADRNR, sy-vline,
WA_E3CVBPA-ABLAD, sy-vline,
WA_E3CVBPA-LAND1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E3CVBPA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E3CVBPA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E3CVBPA INTO WA_E3CVBPA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3CVBPA-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBPA-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_E3CVBPA-PARVW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBPA-PARVW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3CVBPA-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBPA-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3CVBPA-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBPA-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3CVBPA-ADRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBPA-ADRNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E3CVBPA_STR,
SUPKZ TYPE STRING,
VBELN TYPE STRING,
POSNR TYPE STRING,
PARVW TYPE STRING,
KUNNR TYPE STRING,
LIFNR TYPE STRING,
PERNR TYPE STRING,
PARNR TYPE STRING,
ADRNR TYPE STRING,
ABLAD TYPE STRING,
LAND1 TYPE STRING,
ADRDA TYPE STRING,
XCPDK TYPE STRING,
HITYP TYPE STRING,
PRFRE TYPE STRING,
BOKRE TYPE STRING,
HISTUNR TYPE STRING,
KNREF TYPE STRING,
LZONE TYPE STRING,
HZUOR TYPE STRING,END OF T_EKKO_STR. DATA: WA_E3CVBPA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E3CVBPA_STR-SUPKZ sy-vline
WA_E3CVBPA_STR-VBELN sy-vline
WA_E3CVBPA_STR-POSNR sy-vline
WA_E3CVBPA_STR-PARVW sy-vline
WA_E3CVBPA_STR-KUNNR sy-vline
WA_E3CVBPA_STR-LIFNR sy-vline
WA_E3CVBPA_STR-PERNR sy-vline
WA_E3CVBPA_STR-PARNR sy-vline
WA_E3CVBPA_STR-ADRNR sy-vline
WA_E3CVBPA_STR-ABLAD sy-vline
WA_E3CVBPA_STR-LAND1 sy-vline
WA_E3CVBPA_STR-ADRDA sy-vline
WA_E3CVBPA_STR-XCPDK sy-vline
WA_E3CVBPA_STR-HITYP sy-vline
WA_E3CVBPA_STR-PRFRE sy-vline
WA_E3CVBPA_STR-BOKRE sy-vline
WA_E3CVBPA_STR-HISTUNR sy-vline
WA_E3CVBPA_STR-KNREF sy-vline
WA_E3CVBPA_STR-LZONE sy-vline
WA_E3CVBPA_STR-HZUOR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.