ABAP Select data from SAP table E3CVBK0 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E3CVBK0 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E3CVBK0. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E3CVBK0 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E3CVBK0 TYPE STANDARD TABLE OF E3CVBK0,
      WA_E3CVBK0 TYPE E3CVBK0,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E3CVBK0> TYPE E3CVBK0.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E3CVBK0.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E3CVBK0
  INTO TABLE IT_E3CVBK0.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E3CVBK0
*  INTO TABLE @DATA(IT_E3CVBK02).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E3CVBK0 INDEX 1 INTO DATA(WA_E3CVBK02).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E3CVBK0 ASSIGNING <E3CVBK0>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E3CVBK0>-SUPKZ = 1.
<E3CVBK0>-VBELN = 1.
<E3CVBK0>-POSNR = 1.
<E3CVBK0>-KONDA = 1.
<E3CVBK0>-KDGRP = 1.
ENDLOOP.

LOOP AT IT_E3CVBK0 INTO WA_E3CVBK0.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E3CVBK0-BZIRK, sy-vline,
WA_E3CVBK0-PLTYP, sy-vline,
WA_E3CVBK0-INCO1, sy-vline,
WA_E3CVBK0-INCO2, sy-vline,
WA_E3CVBK0-KZAZU, sy-vline,
WA_E3CVBK0-PERFK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E3CVBK0 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E3CVBK0 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E3CVBK0 INTO WA_E3CVBK0. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3CVBK0-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBK0-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURRF CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_E3CVBK0-KURRF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBK0-KURRF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSK CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_E3CVBK0-KURSK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBK0-KURSK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_E3CVBK0-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBK0-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field STCUR CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_E3CVBK0-STCUR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBK0-STCUR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E3CVBK0_STR,
SUPKZ TYPE STRING,
VBELN TYPE STRING,
POSNR TYPE STRING,
KONDA TYPE STRING,
KDGRP TYPE STRING,
BZIRK TYPE STRING,
PLTYP TYPE STRING,
INCO1 TYPE STRING,
INCO2 TYPE STRING,
KZAZU TYPE STRING,
PERFK TYPE STRING,
PERRL TYPE STRING,
MRNKZ TYPE STRING,
KURRF TYPE STRING,
VALTG TYPE STRING,
VALDT TYPE STRING,
ZTERM TYPE STRING,
ZLSCH TYPE STRING,
KTGRD TYPE STRING,
KURSK TYPE STRING,
PRSDT TYPE STRING,
FKDAT TYPE STRING,
FBUDA TYPE STRING,
GJAHR TYPE STRING,
POPER TYPE STRING,
STCUR TYPE STRING,
MSCHL TYPE STRING,
MANSP TYPE STRING,
FPLNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_E3CVBK0_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E3CVBK0_STR-SUPKZ sy-vline
WA_E3CVBK0_STR-VBELN sy-vline
WA_E3CVBK0_STR-POSNR sy-vline
WA_E3CVBK0_STR-KONDA sy-vline
WA_E3CVBK0_STR-KDGRP sy-vline
WA_E3CVBK0_STR-BZIRK sy-vline
WA_E3CVBK0_STR-PLTYP sy-vline
WA_E3CVBK0_STR-INCO1 sy-vline
WA_E3CVBK0_STR-INCO2 sy-vline
WA_E3CVBK0_STR-KZAZU sy-vline
WA_E3CVBK0_STR-PERFK sy-vline
WA_E3CVBK0_STR-PERRL sy-vline
WA_E3CVBK0_STR-MRNKZ sy-vline
WA_E3CVBK0_STR-KURRF sy-vline
WA_E3CVBK0_STR-VALTG sy-vline
WA_E3CVBK0_STR-VALDT sy-vline
WA_E3CVBK0_STR-ZTERM sy-vline
WA_E3CVBK0_STR-ZLSCH sy-vline
WA_E3CVBK0_STR-KTGRD sy-vline
WA_E3CVBK0_STR-KURSK sy-vline
WA_E3CVBK0_STR-PRSDT sy-vline
WA_E3CVBK0_STR-FKDAT sy-vline
WA_E3CVBK0_STR-FBUDA sy-vline
WA_E3CVBK0_STR-GJAHR sy-vline
WA_E3CVBK0_STR-POPER sy-vline
WA_E3CVBK0_STR-STCUR sy-vline
WA_E3CVBK0_STR-MSCHL sy-vline
WA_E3CVBK0_STR-MANSP sy-vline
WA_E3CVBK0_STR-FPLNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.