ABAP Select data from SAP table E3CVBFA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E3CVBFA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E3CVBFA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E3CVBFA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E3CVBFA TYPE STANDARD TABLE OF E3CVBFA,
      WA_E3CVBFA TYPE E3CVBFA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E3CVBFA> TYPE E3CVBFA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E3CVBFA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E3CVBFA
  INTO TABLE IT_E3CVBFA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E3CVBFA
*  INTO TABLE @DATA(IT_E3CVBFA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E3CVBFA INDEX 1 INTO DATA(WA_E3CVBFA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E3CVBFA ASSIGNING <E3CVBFA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E3CVBFA>-SUPKZ = 1.
<E3CVBFA>-VBELV = 1.
<E3CVBFA>-POSNV = 1.
<E3CVBFA>-VBELN = 1.
<E3CVBFA>-POSNN = 1.
ENDLOOP.

LOOP AT IT_E3CVBFA INTO WA_E3CVBFA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E3CVBFA-VBTYP_N, sy-vline,
WA_E3CVBFA-RFMNG, sy-vline,
WA_E3CVBFA-MEINS, sy-vline,
WA_E3CVBFA-RFWRT, sy-vline,
WA_E3CVBFA-WAERS, sy-vline,
WA_E3CVBFA-VBTYP_V, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E3CVBFA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E3CVBFA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E3CVBFA INTO WA_E3CVBFA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3CVBFA-VBELV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBFA-VBELV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E3CVBFA-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBFA-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3CVBFA-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBFA-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_E3CVBFA-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBFA-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3CVBFA-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBFA-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_E3CVBFA-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E3CVBFA-VOLEH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E3CVBFA_STR,
SUPKZ TYPE STRING,
VBELV TYPE STRING,
POSNV TYPE STRING,
VBELN TYPE STRING,
POSNN TYPE STRING,
VBTYP_N TYPE STRING,
RFMNG TYPE STRING,
MEINS TYPE STRING,
RFWRT TYPE STRING,
WAERS TYPE STRING,
VBTYP_V TYPE STRING,
PLMIN TYPE STRING,
TAQUI TYPE STRING,
ERDAT TYPE STRING,
ERZET TYPE STRING,
MATNR TYPE STRING,
BWART TYPE STRING,
BDART TYPE STRING,
PLART TYPE STRING,
STUFE TYPE STRING,
LGNUM TYPE STRING,
AEDAT TYPE STRING,
FKTYP TYPE STRING,
BRGEW TYPE STRING,
GEWEI TYPE STRING,
VOLUM TYPE STRING,
VOLEH TYPE STRING,
FPLNR TYPE STRING,
FPLTR TYPE STRING,
RFMNG_FLO TYPE STRING,END OF T_EKKO_STR. DATA: WA_E3CVBFA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E3CVBFA_STR-SUPKZ sy-vline
WA_E3CVBFA_STR-VBELV sy-vline
WA_E3CVBFA_STR-POSNV sy-vline
WA_E3CVBFA_STR-VBELN sy-vline
WA_E3CVBFA_STR-POSNN sy-vline
WA_E3CVBFA_STR-VBTYP_N sy-vline
WA_E3CVBFA_STR-RFMNG sy-vline
WA_E3CVBFA_STR-MEINS sy-vline
WA_E3CVBFA_STR-RFWRT sy-vline
WA_E3CVBFA_STR-WAERS sy-vline
WA_E3CVBFA_STR-VBTYP_V sy-vline
WA_E3CVBFA_STR-PLMIN sy-vline
WA_E3CVBFA_STR-TAQUI sy-vline
WA_E3CVBFA_STR-ERDAT sy-vline
WA_E3CVBFA_STR-ERZET sy-vline
WA_E3CVBFA_STR-MATNR sy-vline
WA_E3CVBFA_STR-BWART sy-vline
WA_E3CVBFA_STR-BDART sy-vline
WA_E3CVBFA_STR-PLART sy-vline
WA_E3CVBFA_STR-STUFE sy-vline
WA_E3CVBFA_STR-LGNUM sy-vline
WA_E3CVBFA_STR-AEDAT sy-vline
WA_E3CVBFA_STR-FKTYP sy-vline
WA_E3CVBFA_STR-BRGEW sy-vline
WA_E3CVBFA_STR-GEWEI sy-vline
WA_E3CVBFA_STR-VOLUM sy-vline
WA_E3CVBFA_STR-VOLEH sy-vline
WA_E3CVBFA_STR-FPLNR sy-vline
WA_E3CVBFA_STR-FPLTR sy-vline
WA_E3CVBFA_STR-RFMNG_FLO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.