ABAP Select data from SAP table E2FIPRT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E2FIPRT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E2FIPRT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E2FIPRT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E2FIPRT TYPE STANDARD TABLE OF E2FIPRT,
      WA_E2FIPRT TYPE E2FIPRT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E2FIPRT> TYPE E2FIPRT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E2FIPRT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E2FIPRT
  INTO TABLE IT_E2FIPRT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E2FIPRT
*  INTO TABLE @DATA(IT_E2FIPRT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E2FIPRT INDEX 1 INTO DATA(WA_E2FIPRT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E2FIPRT ASSIGNING <E2FIPRT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E2FIPRT>-ZFBDT = 1.
<E2FIPRT>-ZBD1T = 1.
<E2FIPRT>-ZBD2T = 1.
<E2FIPRT>-ZBD3T = 1.
<E2FIPRT>-ZBD1P = 1.
ENDLOOP.

LOOP AT IT_E2FIPRT INTO WA_E2FIPRT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E2FIPRT-ZBD2P, sy-vline,
WA_E2FIPRT-SKFBT, sy-vline,
WA_E2FIPRT-SKNTO, sy-vline,
WA_E2FIPRT-SKNT2, sy-vline,
WA_E2FIPRT-SKNT3, sy-vline,
WA_E2FIPRT-WSKTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E2FIPRT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E2FIPRT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E2FIPRT INTO WA_E2FIPRT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field REBZG CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E2FIPRT-REBZG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E2FIPRT-REBZG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ESRRE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E2FIPRT-ESRRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E2FIPRT-ESRRE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EMPFB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E2FIPRT-EMPFB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E2FIPRT-EMPFB.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E2FIPRT_STR,
ZFBDT TYPE STRING,
ZBD1T TYPE STRING,
ZBD2T TYPE STRING,
ZBD3T TYPE STRING,
ZBD1P TYPE STRING,
ZBD2P TYPE STRING,
SKFBT TYPE STRING,
SKNTO TYPE STRING,
SKNT2 TYPE STRING,
SKNT3 TYPE STRING,
WSKTO TYPE STRING,
ZLSCH TYPE STRING,
ZLSPR TYPE STRING,
ZBFIX TYPE STRING,
REBZG TYPE STRING,
REBZJ TYPE STRING,
REBZZ TYPE STRING,
MSCHL TYPE STRING,
MANSP TYPE STRING,
RSTGR TYPE STRING,
QSSKZ TYPE STRING,
QSSHB TYPE STRING,
QSFBT TYPE STRING,
STCEG TYPE STRING,
UZAWE TYPE STRING,
LZBKZ TYPE STRING,
LANDL TYPE STRING,
DIEKZ TYPE STRING,
ESRNR TYPE STRING,
ESRRE TYPE STRING,
ESRPZ TYPE STRING,
HBKID TYPE STRING,
BVTYP TYPE STRING,
EMPFB TYPE STRING,
ZTERM TYPE STRING,
KIDNO TYPE STRING,
PYCUR TYPE STRING,
PYAMT TYPE STRING,END OF T_EKKO_STR. DATA: WA_E2FIPRT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E2FIPRT_STR-ZFBDT sy-vline
WA_E2FIPRT_STR-ZBD1T sy-vline
WA_E2FIPRT_STR-ZBD2T sy-vline
WA_E2FIPRT_STR-ZBD3T sy-vline
WA_E2FIPRT_STR-ZBD1P sy-vline
WA_E2FIPRT_STR-ZBD2P sy-vline
WA_E2FIPRT_STR-SKFBT sy-vline
WA_E2FIPRT_STR-SKNTO sy-vline
WA_E2FIPRT_STR-SKNT2 sy-vline
WA_E2FIPRT_STR-SKNT3 sy-vline
WA_E2FIPRT_STR-WSKTO sy-vline
WA_E2FIPRT_STR-ZLSCH sy-vline
WA_E2FIPRT_STR-ZLSPR sy-vline
WA_E2FIPRT_STR-ZBFIX sy-vline
WA_E2FIPRT_STR-REBZG sy-vline
WA_E2FIPRT_STR-REBZJ sy-vline
WA_E2FIPRT_STR-REBZZ sy-vline
WA_E2FIPRT_STR-MSCHL sy-vline
WA_E2FIPRT_STR-MANSP sy-vline
WA_E2FIPRT_STR-RSTGR sy-vline
WA_E2FIPRT_STR-QSSKZ sy-vline
WA_E2FIPRT_STR-QSSHB sy-vline
WA_E2FIPRT_STR-QSFBT sy-vline
WA_E2FIPRT_STR-STCEG sy-vline
WA_E2FIPRT_STR-UZAWE sy-vline
WA_E2FIPRT_STR-LZBKZ sy-vline
WA_E2FIPRT_STR-LANDL sy-vline
WA_E2FIPRT_STR-DIEKZ sy-vline
WA_E2FIPRT_STR-ESRNR sy-vline
WA_E2FIPRT_STR-ESRRE sy-vline
WA_E2FIPRT_STR-ESRPZ sy-vline
WA_E2FIPRT_STR-HBKID sy-vline
WA_E2FIPRT_STR-BVTYP sy-vline
WA_E2FIPRT_STR-EMPFB sy-vline
WA_E2FIPRT_STR-ZTERM sy-vline
WA_E2FIPRT_STR-KIDNO sy-vline
WA_E2FIPRT_STR-PYCUR sy-vline
WA_E2FIPRT_STR-PYAMT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.