ABAP Select data from SAP table E2EIE_TC_TEMPL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E2EIE_TC_TEMPL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E2EIE_TC_TEMPL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E2EIE_TC_TEMPL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E2EIE_TC_TEMPL TYPE STANDARD TABLE OF E2EIE_TC_TEMPL,
      WA_E2EIE_TC_TEMPL TYPE E2EIE_TC_TEMPL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E2EIE_TC_TEMPL> TYPE E2EIE_TC_TEMPL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E2EIE_TC_TEMPL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E2EIE_TC_TEMPL
  INTO TABLE IT_E2EIE_TC_TEMPL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E2EIE_TC_TEMPL
*  INTO TABLE @DATA(IT_E2EIE_TC_TEMPL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E2EIE_TC_TEMPL INDEX 1 INTO DATA(WA_E2EIE_TC_TEMPL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E2EIE_TC_TEMPL ASSIGNING <E2EIE_TC_TEMPL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E2EIE_TC_TEMPL>-PRJID = 1.
<E2EIE_TC_TEMPL>-BPDID = 1.
<E2EIE_TC_TEMPL>-VERSION = 1.
<E2EIE_TC_TEMPL>-SEQNUM = 1.
<E2EIE_TC_TEMPL>-APP = 1.
ENDLOOP.

LOOP AT IT_E2EIE_TC_TEMPL INTO WA_E2EIE_TC_TEMPL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E2EIE_TC_TEMPL-ACTIVATE, sy-vline,
WA_E2EIE_TC_TEMPL-BPDTYPE, sy-vline,
WA_E2EIE_TC_TEMPL-DESCRIPTION, sy-vline,
WA_E2EIE_TC_TEMPL-BPDTEXT, sy-vline,
WA_E2EIE_TC_TEMPL-SPRAS, sy-vline,
WA_E2EIE_TC_TEMPL-LAND1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E2EIE_TC_TEMPL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E2EIE_TC_TEMPL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E2EIE_TC_TEMPL INTO WA_E2EIE_TC_TEMPL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_E2EIE_TC_TEMPL-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E2EIE_TC_TEMPL-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E2EIE_TC_TEMPL_STR,
PRJID TYPE STRING,
BPDID TYPE STRING,
VERSION TYPE STRING,
SEQNUM TYPE STRING,
APP TYPE STRING,
ACTIVATE TYPE STRING,
BPDTYPE TYPE STRING,
DESCRIPTION TYPE STRING,
BPDTEXT TYPE STRING,
SPRAS TYPE STRING,
LAND1 TYPE STRING,
STATUS TYPE STRING,
USERNAME TYPE STRING,
CDAT TYPE STRING,
TIME TYPE STRING,
FLAG TYPE STRING,
COUNTRY TYPE STRING,
E2EBPD TYPE STRING,END OF T_EKKO_STR. DATA: WA_E2EIE_TC_TEMPL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E2EIE_TC_TEMPL_STR-PRJID sy-vline
WA_E2EIE_TC_TEMPL_STR-BPDID sy-vline
WA_E2EIE_TC_TEMPL_STR-VERSION sy-vline
WA_E2EIE_TC_TEMPL_STR-SEQNUM sy-vline
WA_E2EIE_TC_TEMPL_STR-APP sy-vline
WA_E2EIE_TC_TEMPL_STR-ACTIVATE sy-vline
WA_E2EIE_TC_TEMPL_STR-BPDTYPE sy-vline
WA_E2EIE_TC_TEMPL_STR-DESCRIPTION sy-vline
WA_E2EIE_TC_TEMPL_STR-BPDTEXT sy-vline
WA_E2EIE_TC_TEMPL_STR-SPRAS sy-vline
WA_E2EIE_TC_TEMPL_STR-LAND1 sy-vline
WA_E2EIE_TC_TEMPL_STR-STATUS sy-vline
WA_E2EIE_TC_TEMPL_STR-USERNAME sy-vline
WA_E2EIE_TC_TEMPL_STR-CDAT sy-vline
WA_E2EIE_TC_TEMPL_STR-TIME sy-vline
WA_E2EIE_TC_TEMPL_STR-FLAG sy-vline
WA_E2EIE_TC_TEMPL_STR-COUNTRY sy-vline
WA_E2EIE_TC_TEMPL_STR-E2EBPD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.