ABAP Select data from SAP table E2EIE_TC_LOG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E2EIE_TC_LOG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E2EIE_TC_LOG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E2EIE_TC_LOG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E2EIE_TC_LOG TYPE STANDARD TABLE OF E2EIE_TC_LOG,
      WA_E2EIE_TC_LOG TYPE E2EIE_TC_LOG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E2EIE_TC_LOG> TYPE E2EIE_TC_LOG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E2EIE_TC_LOG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E2EIE_TC_LOG
  INTO TABLE IT_E2EIE_TC_LOG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E2EIE_TC_LOG
*  INTO TABLE @DATA(IT_E2EIE_TC_LOG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E2EIE_TC_LOG INDEX 1 INTO DATA(WA_E2EIE_TC_LOG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E2EIE_TC_LOG ASSIGNING <E2EIE_TC_LOG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E2EIE_TC_LOG>-MANDT = 1.
<E2EIE_TC_LOG>-LOGID = 1.
<E2EIE_TC_LOG>-TESTPLANID = 1.
<E2EIE_TC_LOG>-BPDNUM = 1.
<E2EIE_TC_LOG>-PEROBJECT = 1.
ENDLOOP.

LOOP AT IT_E2EIE_TC_LOG INTO WA_E2EIE_TC_LOG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E2EIE_TC_LOG-VARIANT, sy-vline,
WA_E2EIE_TC_LOG-SEQNUM, sy-vline,
WA_E2EIE_TC_LOG-OBJECTID, sy-vline,
WA_E2EIE_TC_LOG-RUNRESULT, sy-vline,
WA_E2EIE_TC_LOG-STATUS, sy-vline,
WA_E2EIE_TC_LOG-PICURL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E2EIE_TC_LOG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E2EIE_TC_LOG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E2EIE_TC_LOG INTO WA_E2EIE_TC_LOG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E2EIE_TC_LOG_STR,
MANDT TYPE STRING,
LOGID TYPE STRING,
TESTPLANID TYPE STRING,
BPDNUM TYPE STRING,
PEROBJECT TYPE STRING,
VARIANT TYPE STRING,
SEQNUM TYPE STRING,
OBJECTID TYPE STRING,
RUNRESULT TYPE STRING,
STATUS TYPE STRING,
PICURL TYPE STRING,
LOGDATUM TYPE STRING,
LOGTIME TYPE STRING,
LOGSTAMP TYPE STRING,
UNAME TYPE STRING,
FIELD1 TYPE STRING,
FIELD2 TYPE STRING,
FIELD3 TYPE STRING,
FIELD4 TYPE STRING,
FIELD5 TYPE STRING,
FIELD6 TYPE STRING,
FIELD7 TYPE STRING,
FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E2EIE_TC_LOG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E2EIE_TC_LOG_STR-MANDT sy-vline
WA_E2EIE_TC_LOG_STR-LOGID sy-vline
WA_E2EIE_TC_LOG_STR-TESTPLANID sy-vline
WA_E2EIE_TC_LOG_STR-BPDNUM sy-vline
WA_E2EIE_TC_LOG_STR-PEROBJECT sy-vline
WA_E2EIE_TC_LOG_STR-VARIANT sy-vline
WA_E2EIE_TC_LOG_STR-SEQNUM sy-vline
WA_E2EIE_TC_LOG_STR-OBJECTID sy-vline
WA_E2EIE_TC_LOG_STR-RUNRESULT sy-vline
WA_E2EIE_TC_LOG_STR-STATUS sy-vline
WA_E2EIE_TC_LOG_STR-PICURL sy-vline
WA_E2EIE_TC_LOG_STR-LOGDATUM sy-vline
WA_E2EIE_TC_LOG_STR-LOGTIME sy-vline
WA_E2EIE_TC_LOG_STR-LOGSTAMP sy-vline
WA_E2EIE_TC_LOG_STR-UNAME sy-vline
WA_E2EIE_TC_LOG_STR-FIELD1 sy-vline
WA_E2EIE_TC_LOG_STR-FIELD2 sy-vline
WA_E2EIE_TC_LOG_STR-FIELD3 sy-vline
WA_E2EIE_TC_LOG_STR-FIELD4 sy-vline
WA_E2EIE_TC_LOG_STR-FIELD5 sy-vline
WA_E2EIE_TC_LOG_STR-FIELD6 sy-vline
WA_E2EIE_TC_LOG_STR-FIELD7 sy-vline
WA_E2EIE_TC_LOG_STR-FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.