ABAP Select data from SAP table E2EIE_TC_ACTNS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E2EIE_TC_ACTNS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E2EIE_TC_ACTNS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E2EIE_TC_ACTNS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E2EIE_TC_ACTNS TYPE STANDARD TABLE OF E2EIE_TC_ACTNS,
      WA_E2EIE_TC_ACTNS TYPE E2EIE_TC_ACTNS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E2EIE_TC_ACTNS> TYPE E2EIE_TC_ACTNS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E2EIE_TC_ACTNS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E2EIE_TC_ACTNS
  INTO TABLE IT_E2EIE_TC_ACTNS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E2EIE_TC_ACTNS
*  INTO TABLE @DATA(IT_E2EIE_TC_ACTNS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E2EIE_TC_ACTNS INDEX 1 INTO DATA(WA_E2EIE_TC_ACTNS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E2EIE_TC_ACTNS ASSIGNING <E2EIE_TC_ACTNS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E2EIE_TC_ACTNS>-ACTIONID = 1.
<E2EIE_TC_ACTNS>-VERSION = 1.
<E2EIE_TC_ACTNS>-NAME = 1.
<E2EIE_TC_ACTNS>-DESCRIPTION = 1.
<E2EIE_TC_ACTNS>-TEXT = 1.
ENDLOOP.

LOOP AT IT_E2EIE_TC_ACTNS INTO WA_E2EIE_TC_ACTNS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E2EIE_TC_ACTNS-CHANGES, sy-vline,
WA_E2EIE_TC_ACTNS-TYPE, sy-vline,
WA_E2EIE_TC_ACTNS-PREACT, sy-vline,
WA_E2EIE_TC_ACTNS-FOLACT, sy-vline,
WA_E2EIE_TC_ACTNS-STEPID, sy-vline,
WA_E2EIE_TC_ACTNS-APPTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E2EIE_TC_ACTNS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E2EIE_TC_ACTNS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E2EIE_TC_ACTNS INTO WA_E2EIE_TC_ACTNS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E2EIE_TC_ACTNS_STR,
ACTIONID TYPE STRING,
VERSION TYPE STRING,
NAME TYPE STRING,
DESCRIPTION TYPE STRING,
TEXT TYPE STRING,
CHANGES TYPE STRING,
TYPE TYPE STRING,
PREACT TYPE STRING,
FOLACT TYPE STRING,
STEPID TYPE STRING,
APPTYPE TYPE STRING,
KEYWORD TYPE STRING,
SELVERSION TYPE STRING,
OBJECT TYPE STRING,
VALUE TYPE STRING,
VALUETYPE TYPE STRING,
DAYSADD TYPE STRING,
ELEMENTID TYPE STRING,
F4URL TYPE STRING,
I18N TYPE STRING,
ENTITYSET TYPE STRING,
CHECKPOINTS TYPE STRING,
FILTER TYPE STRING,
FILTER2 TYPE STRING,
FILTER3 TYPE STRING,
FILTER4 TYPE STRING,
FILTER5 TYPE STRING,
PROPERTY1 TYPE STRING,
PROPERTY2 TYPE STRING,
PROPERTY3 TYPE STRING,
ACTIVATE TYPE STRING,
CHABLE TYPE STRING,
INSERTNEW TYPE STRING,
UNAME TYPE STRING,
UDATE TYPE STRING,
FLAG TYPE STRING,
FIELD1 TYPE STRING,
FIELD2 TYPE STRING,
FIELD3 TYPE STRING,
FIELD4 TYPE STRING,
FIELD5 TYPE STRING,
FIELD6 TYPE STRING,
FIELD7 TYPE STRING,END OF T_EKKO_STR. DATA: WA_E2EIE_TC_ACTNS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E2EIE_TC_ACTNS_STR-ACTIONID sy-vline
WA_E2EIE_TC_ACTNS_STR-VERSION sy-vline
WA_E2EIE_TC_ACTNS_STR-NAME sy-vline
WA_E2EIE_TC_ACTNS_STR-DESCRIPTION sy-vline
WA_E2EIE_TC_ACTNS_STR-TEXT sy-vline
WA_E2EIE_TC_ACTNS_STR-CHANGES sy-vline
WA_E2EIE_TC_ACTNS_STR-TYPE sy-vline
WA_E2EIE_TC_ACTNS_STR-PREACT sy-vline
WA_E2EIE_TC_ACTNS_STR-FOLACT sy-vline
WA_E2EIE_TC_ACTNS_STR-STEPID sy-vline
WA_E2EIE_TC_ACTNS_STR-APPTYPE sy-vline
WA_E2EIE_TC_ACTNS_STR-KEYWORD sy-vline
WA_E2EIE_TC_ACTNS_STR-SELVERSION sy-vline
WA_E2EIE_TC_ACTNS_STR-OBJECT sy-vline
WA_E2EIE_TC_ACTNS_STR-VALUE sy-vline
WA_E2EIE_TC_ACTNS_STR-VALUETYPE sy-vline
WA_E2EIE_TC_ACTNS_STR-DAYSADD sy-vline
WA_E2EIE_TC_ACTNS_STR-ELEMENTID sy-vline
WA_E2EIE_TC_ACTNS_STR-F4URL sy-vline
WA_E2EIE_TC_ACTNS_STR-I18N sy-vline
WA_E2EIE_TC_ACTNS_STR-ENTITYSET sy-vline
WA_E2EIE_TC_ACTNS_STR-CHECKPOINTS sy-vline
WA_E2EIE_TC_ACTNS_STR-FILTER sy-vline
WA_E2EIE_TC_ACTNS_STR-FILTER2 sy-vline
WA_E2EIE_TC_ACTNS_STR-FILTER3 sy-vline
WA_E2EIE_TC_ACTNS_STR-FILTER4 sy-vline
WA_E2EIE_TC_ACTNS_STR-FILTER5 sy-vline
WA_E2EIE_TC_ACTNS_STR-PROPERTY1 sy-vline
WA_E2EIE_TC_ACTNS_STR-PROPERTY2 sy-vline
WA_E2EIE_TC_ACTNS_STR-PROPERTY3 sy-vline
WA_E2EIE_TC_ACTNS_STR-ACTIVATE sy-vline
WA_E2EIE_TC_ACTNS_STR-CHABLE sy-vline
WA_E2EIE_TC_ACTNS_STR-INSERTNEW sy-vline
WA_E2EIE_TC_ACTNS_STR-UNAME sy-vline
WA_E2EIE_TC_ACTNS_STR-UDATE sy-vline
WA_E2EIE_TC_ACTNS_STR-FLAG sy-vline
WA_E2EIE_TC_ACTNS_STR-FIELD1 sy-vline
WA_E2EIE_TC_ACTNS_STR-FIELD2 sy-vline
WA_E2EIE_TC_ACTNS_STR-FIELD3 sy-vline
WA_E2EIE_TC_ACTNS_STR-FIELD4 sy-vline
WA_E2EIE_TC_ACTNS_STR-FIELD5 sy-vline
WA_E2EIE_TC_ACTNS_STR-FIELD6 sy-vline
WA_E2EIE_TC_ACTNS_STR-FIELD7 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.