ABAP Select data from SAP table E2EIE_CC_S_ACTVTY_CRIT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E2EIE_CC_S_ACTVTY_CRIT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E2EIE_CC_S_ACTVTY_CRIT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E2EIE_CC_S_ACTVTY_CRIT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E2EIE_CC_S_ACTVTY_CRIT TYPE STANDARD TABLE OF E2EIE_CC_S_ACTVTY_CRIT, WA_E2EIE_CC_S_ACTVTY_CRIT TYPE E2EIE_CC_S_ACTVTY_CRIT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <E2EIE_CC_S_ACTVTY_CRIT> TYPE E2EIE_CC_S_ACTVTY_CRIT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_E2EIE_CC_S_ACTVTY_CRIT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM E2EIE_CC_S_ACTVTY_CRIT INTO TABLE IT_E2EIE_CC_S_ACTVTY_CRIT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM E2EIE_CC_S_ACTVTY_CRIT * INTO TABLE @DATA(IT_E2EIE_CC_S_ACTVTY_CRIT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_E2EIE_CC_S_ACTVTY_CRIT INDEX 1 INTO DATA(WA_E2EIE_CC_S_ACTVTY_CRIT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_E2EIE_CC_S_ACTVTY_CRIT ASSIGNING <E2EIE_CC_S_ACTVTY_CRIT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<E2EIE_CC_S_ACTVTY_CRIT>-CRITERION_KEY = 1.
<E2EIE_CC_S_ACTVTY_CRIT>-ACTIVITY_ID = 1.
<E2EIE_CC_S_ACTVTY_CRIT>-ACTIVITY_SEQ_NUM = 1.
<E2EIE_CC_S_ACTVTY_CRIT>-RELEVANT_IND = 1.
<E2EIE_CC_S_ACTVTY_CRIT>-QUALIFIER_DESCR = 1.
ENDLOOP. LOOP AT IT_E2EIE_CC_S_ACTVTY_CRIT INTO WA_E2EIE_CC_S_ACTVTY_CRIT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E2EIE_CC_S_ACTVTY_CRIT-VISIBILITY, sy-vline,
WA_E2EIE_CC_S_ACTVTY_CRIT-DLV_YEAR_LOW, sy-vline,
WA_E2EIE_CC_S_ACTVTY_CRIT-DLV_NUMBER_LOW, sy-vline,
WA_E2EIE_CC_S_ACTVTY_CRIT-DLV_YEAR_HIGH, sy-vline,
WA_E2EIE_CC_S_ACTVTY_CRIT-DLV_NUMBER_HIGH, sy-vline,
WA_E2EIE_CC_S_ACTVTY_CRIT-EXCLUDING_IND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E2EIE_CC_S_ACTVTY_CRIT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E2EIE_CC_S_ACTVTY_CRIT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E2EIE_CC_S_ACTVTY_CRIT INTO WA_E2EIE_CC_S_ACTVTY_CRIT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E2EIE_CC_S_ACTVTY_CRIT_STR,
CRITERION_KEY TYPE STRING,
ACTIVITY_ID TYPE STRING,
ACTIVITY_SEQ_NUM TYPE STRING,
RELEVANT_IND TYPE STRING,
QUALIFIER_DESCR TYPE STRING,
VISIBILITY TYPE STRING,
DLV_YEAR_LOW TYPE STRING,
DLV_NUMBER_LOW TYPE STRING,
DLV_YEAR_HIGH TYPE STRING,
DLV_NUMBER_HIGH TYPE STRING,
EXCLUDING_IND TYPE STRING,
COUNTRY TYPE STRING,
SOLUTION_ID TYPE STRING,
BLDNG_BLCK_ID TYPE STRING,
SCENARIO_GROUP_ID TYPE STRING,
SCENARIO_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_E2EIE_CC_S_ACTVTY_CRIT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-CRITERION_KEY sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-ACTIVITY_ID sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-ACTIVITY_SEQ_NUM sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-RELEVANT_IND sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-QUALIFIER_DESCR sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-VISIBILITY sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-DLV_YEAR_LOW sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-DLV_NUMBER_LOW sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-DLV_YEAR_HIGH sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-DLV_NUMBER_HIGH sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-EXCLUDING_IND sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-COUNTRY sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-SOLUTION_ID sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-BLDNG_BLCK_ID sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-SCENARIO_GROUP_ID sy-vline
WA_E2EIE_CC_S_ACTVTY_CRIT_STR-SCENARIO_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.