ABAP Select data from SAP table E1PLMZP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1PLMZP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1PLMZP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1PLMZP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1PLMZP TYPE STANDARD TABLE OF E1PLMZP,
      WA_E1PLMZP TYPE E1PLMZP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1PLMZP> TYPE E1PLMZP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1PLMZP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1PLMZP
  INTO TABLE IT_E1PLMZP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1PLMZP
*  INTO TABLE @DATA(IT_E1PLMZP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1PLMZP INDEX 1 INTO DATA(WA_E1PLMZP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1PLMZP ASSIGNING <E1PLMZP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1PLMZP>-ZUONR = 1.
<E1PLMZP>-STLTY = 1.
<E1PLMZP>-STLAN = 1.
<E1PLMZP>-STLNR = 1.
<E1PLMZP>-STLAL = 1.
ENDLOOP.

LOOP AT IT_E1PLMZP INTO WA_E1PLMZP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1PLMZP-BOM_VERSN, sy-vline,
WA_E1PLMZP-STLKN, sy-vline,
WA_E1PLMZP-POSNR, sy-vline,
WA_E1PLMZP-STVKN, sy-vline,
WA_E1PLMZP-STVKN_VERSN, sy-vline,
WA_E1PLMZP-IDNRK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1PLMZP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1PLMZP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1PLMZP INTO WA_E1PLMZP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1PLMZP_STR,
ZUONR TYPE STRING,
STLTY TYPE STRING,
STLAN TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
BOM_VERSN TYPE STRING,
STLKN TYPE STRING,
POSNR TYPE STRING,
STVKN TYPE STRING,
STVKN_VERSN TYPE STRING,
IDNRK TYPE STRING,
BASE_UOM TYPE STRING,
QUANTITY TYPE STRING,
SEQUENCE_NO TYPE STRING,
POSTP TYPE STRING,
SORTF TYPE STRING,
FMENG TYPE STRING,
LOEKZ TYPE STRING,
RGEKZ TYPE STRING,
LGORT TYPE STRING,
AOBAR TYPE STRING,
ABLAD TYPE STRING,
ZEINH TYPE STRING,
DAUER TYPE STRING,
PRODFLOWID TYPE STRING,
AENNR TYPE STRING,
BOMITEM_AENNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1PLMZP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1PLMZP_STR-ZUONR sy-vline
WA_E1PLMZP_STR-STLTY sy-vline
WA_E1PLMZP_STR-STLAN sy-vline
WA_E1PLMZP_STR-STLNR sy-vline
WA_E1PLMZP_STR-STLAL sy-vline
WA_E1PLMZP_STR-BOM_VERSN sy-vline
WA_E1PLMZP_STR-STLKN sy-vline
WA_E1PLMZP_STR-POSNR sy-vline
WA_E1PLMZP_STR-STVKN sy-vline
WA_E1PLMZP_STR-STVKN_VERSN sy-vline
WA_E1PLMZP_STR-IDNRK sy-vline
WA_E1PLMZP_STR-BASE_UOM sy-vline
WA_E1PLMZP_STR-QUANTITY sy-vline
WA_E1PLMZP_STR-SEQUENCE_NO sy-vline
WA_E1PLMZP_STR-POSTP sy-vline
WA_E1PLMZP_STR-SORTF sy-vline
WA_E1PLMZP_STR-FMENG sy-vline
WA_E1PLMZP_STR-LOEKZ sy-vline
WA_E1PLMZP_STR-RGEKZ sy-vline
WA_E1PLMZP_STR-LGORT sy-vline
WA_E1PLMZP_STR-AOBAR sy-vline
WA_E1PLMZP_STR-ABLAD sy-vline
WA_E1PLMZP_STR-ZEINH sy-vline
WA_E1PLMZP_STR-DAUER sy-vline
WA_E1PLMZP_STR-PRODFLOWID sy-vline
WA_E1PLMZP_STR-AENNR sy-vline
WA_E1PLMZP_STR-BOMITEM_AENNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.