ABAP Select data from SAP table E1PLFLL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1PLFLL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1PLFLL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1PLFLL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1PLFLL TYPE STANDARD TABLE OF E1PLFLL,
      WA_E1PLFLL TYPE E1PLFLL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1PLFLL> TYPE E1PLFLL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1PLFLL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1PLFLL
  INTO TABLE IT_E1PLFLL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1PLFLL
*  INTO TABLE @DATA(IT_E1PLFLL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1PLFLL INDEX 1 INTO DATA(WA_E1PLFLL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1PLFLL ASSIGNING <E1PLFLL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1PLFLL>-MSGFN = 1.
<E1PLFLL>-PLNFL = 1.
<E1PLFLL>-AUSCHL = 1.
<E1PLFLL>-DATUB = 1.
<E1PLFLL>-DATUV = 1.
ENDLOOP.

LOOP AT IT_E1PLFLL INTO WA_E1PLFLL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1PLFLL-FLGAT, sy-vline,
WA_E1PLFLL-LOSBS, sy-vline,
WA_E1PLFLL-LOSVN, sy-vline,
WA_E1PLFLL-LTXA1, sy-vline,
WA_E1PLFLL-VORNR1, sy-vline,
WA_E1PLFLL-VORNR2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1PLFLL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1PLFLL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1PLFLL INTO WA_E1PLFLL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E1PLFLL-PLNFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1PLFLL-PLNFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR1 CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_E1PLFLL-VORNR1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1PLFLL-VORNR1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR2 CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_E1PLFLL-VORNR2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1PLFLL-VORNR2.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1PLFLL_STR,
MSGFN TYPE STRING,
PLNFL TYPE STRING,
AUSCHL TYPE STRING,
DATUB TYPE STRING,
DATUV TYPE STRING,
FLGAT TYPE STRING,
LOSBS TYPE STRING,
LOSVN TYPE STRING,
LTXA1 TYPE STRING,
VORNR1 TYPE STRING,
VORNR2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1PLFLL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1PLFLL_STR-MSGFN sy-vline
WA_E1PLFLL_STR-PLNFL sy-vline
WA_E1PLFLL_STR-AUSCHL sy-vline
WA_E1PLFLL_STR-DATUB sy-vline
WA_E1PLFLL_STR-DATUV sy-vline
WA_E1PLFLL_STR-FLGAT sy-vline
WA_E1PLFLL_STR-LOSBS sy-vline
WA_E1PLFLL_STR-LOSVN sy-vline
WA_E1PLFLL_STR-LTXA1 sy-vline
WA_E1PLFLL_STR-VORNR1 sy-vline
WA_E1PLFLL_STR-VORNR2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.