ABAP Select data from SAP table E1P2010 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1P2010 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1P2010. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1P2010 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1P2010 TYPE STANDARD TABLE OF E1P2010,
      WA_E1P2010 TYPE E1P2010,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1P2010> TYPE E1P2010.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1P2010.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1P2010
  INTO TABLE IT_E1P2010.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1P2010
*  INTO TABLE @DATA(IT_E1P20102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1P2010 INDEX 1 INTO DATA(WA_E1P20102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1P2010 ASSIGNING <E1P2010>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1P2010>-PERNR = 1.
<E1P2010>-INFTY = 1.
<E1P2010>-SUBTY = 1.
<E1P2010>-OBJPS = 1.
<E1P2010>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_E1P2010 INTO WA_E1P2010.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1P2010-ENDDA, sy-vline,
WA_E1P2010-BEGDA, sy-vline,
WA_E1P2010-SEQNR, sy-vline,
WA_E1P2010-AEDTM, sy-vline,
WA_E1P2010-UNAME, sy-vline,
WA_E1P2010-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1P2010 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1P2010 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1P2010 INTO WA_E1P2010. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1P2010_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
BEGUZ TYPE STRING,
ENDUZ TYPE STRING,
VTKEN TYPE STRING,
STDAZ TYPE STRING,
LGART TYPE STRING,
ANZHL TYPE STRING,
ZEINH TYPE STRING,
BWGRL TYPE STRING,
AUFKZ TYPE STRING,
BETRG TYPE STRING,
ENDOF TYPE STRING,
UFLD1 TYPE STRING,
UFLD2 TYPE STRING,
UFLD3 TYPE STRING,
KEYPR TYPE STRING,
TRFGR TYPE STRING,
TRFST TYPE STRING,
PRAKN TYPE STRING,
PRAKZ TYPE STRING,
OTYPE TYPE STRING,
PLANS TYPE STRING,
VERSL TYPE STRING,
EXBEL TYPE STRING,
WAERS TYPE STRING,
LOGSYS TYPE STRING,
AWTYP TYPE STRING,
AWREF TYPE STRING,
AWORG TYPE STRING,
WTART TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1P2010_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1P2010_STR-PERNR sy-vline
WA_E1P2010_STR-INFTY sy-vline
WA_E1P2010_STR-SUBTY sy-vline
WA_E1P2010_STR-OBJPS sy-vline
WA_E1P2010_STR-SPRPS sy-vline
WA_E1P2010_STR-ENDDA sy-vline
WA_E1P2010_STR-BEGDA sy-vline
WA_E1P2010_STR-SEQNR sy-vline
WA_E1P2010_STR-AEDTM sy-vline
WA_E1P2010_STR-UNAME sy-vline
WA_E1P2010_STR-HISTO sy-vline
WA_E1P2010_STR-ITXEX sy-vline
WA_E1P2010_STR-REFEX sy-vline
WA_E1P2010_STR-ORDEX sy-vline
WA_E1P2010_STR-ITBLD sy-vline
WA_E1P2010_STR-PREAS sy-vline
WA_E1P2010_STR-FLAG1 sy-vline
WA_E1P2010_STR-FLAG2 sy-vline
WA_E1P2010_STR-FLAG3 sy-vline
WA_E1P2010_STR-FLAG4 sy-vline
WA_E1P2010_STR-RESE1 sy-vline
WA_E1P2010_STR-RESE2 sy-vline
WA_E1P2010_STR-GRPVL sy-vline
WA_E1P2010_STR-BEGUZ sy-vline
WA_E1P2010_STR-ENDUZ sy-vline
WA_E1P2010_STR-VTKEN sy-vline
WA_E1P2010_STR-STDAZ sy-vline
WA_E1P2010_STR-LGART sy-vline
WA_E1P2010_STR-ANZHL sy-vline
WA_E1P2010_STR-ZEINH sy-vline
WA_E1P2010_STR-BWGRL sy-vline
WA_E1P2010_STR-AUFKZ sy-vline
WA_E1P2010_STR-BETRG sy-vline
WA_E1P2010_STR-ENDOF sy-vline
WA_E1P2010_STR-UFLD1 sy-vline
WA_E1P2010_STR-UFLD2 sy-vline
WA_E1P2010_STR-UFLD3 sy-vline
WA_E1P2010_STR-KEYPR sy-vline
WA_E1P2010_STR-TRFGR sy-vline
WA_E1P2010_STR-TRFST sy-vline
WA_E1P2010_STR-PRAKN sy-vline
WA_E1P2010_STR-PRAKZ sy-vline
WA_E1P2010_STR-OTYPE sy-vline
WA_E1P2010_STR-PLANS sy-vline
WA_E1P2010_STR-VERSL sy-vline
WA_E1P2010_STR-EXBEL sy-vline
WA_E1P2010_STR-WAERS sy-vline
WA_E1P2010_STR-LOGSYS sy-vline
WA_E1P2010_STR-AWTYP sy-vline
WA_E1P2010_STR-AWREF sy-vline
WA_E1P2010_STR-AWORG sy-vline
WA_E1P2010_STR-WTART sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.