ABAP Select data from SAP table E1P1222 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1P1222 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1P1222. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1P1222 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1P1222 TYPE STANDARD TABLE OF E1P1222,
      WA_E1P1222 TYPE E1P1222,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1P1222> TYPE E1P1222.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1P1222.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1P1222
  INTO TABLE IT_E1P1222.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1P1222
*  INTO TABLE @DATA(IT_E1P12222).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1P1222 INDEX 1 INTO DATA(WA_E1P12222).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1P1222 ASSIGNING <E1P1222>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1P1222>-MANDT = 1.
<E1P1222>-PLVAR = 1.
<E1P1222>-OTYPE = 1.
<E1P1222>-OBJID = 1.
<E1P1222>-INFTY = 1.
ENDLOOP.

LOOP AT IT_E1P1222 INTO WA_E1P1222.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1P1222-SUBTY, sy-vline,
WA_E1P1222-ISTAT, sy-vline,
WA_E1P1222-PRIOX, sy-vline,
WA_E1P1222-BEGDA, sy-vline,
WA_E1P1222-ENDDA, sy-vline,
WA_E1P1222-VARYF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1P1222 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1P1222 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1P1222 INTO WA_E1P1222. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1P1222_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
PRIOX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
TABNR TYPE STRING,
TABSEQNR TYPE STRING,
ATTRIB TYPE STRING,
LOW TYPE STRING,
HIGH TYPE STRING,
EXCLUDED TYPE STRING,
DEFAULTVAL TYPE STRING,
INHERITED TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1P1222_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1P1222_STR-MANDT sy-vline
WA_E1P1222_STR-PLVAR sy-vline
WA_E1P1222_STR-OTYPE sy-vline
WA_E1P1222_STR-OBJID sy-vline
WA_E1P1222_STR-INFTY sy-vline
WA_E1P1222_STR-SUBTY sy-vline
WA_E1P1222_STR-ISTAT sy-vline
WA_E1P1222_STR-PRIOX sy-vline
WA_E1P1222_STR-BEGDA sy-vline
WA_E1P1222_STR-ENDDA sy-vline
WA_E1P1222_STR-VARYF sy-vline
WA_E1P1222_STR-SEQNR sy-vline
WA_E1P1222_STR-AEDTM sy-vline
WA_E1P1222_STR-UNAME sy-vline
WA_E1P1222_STR-REASN sy-vline
WA_E1P1222_STR-HISTO sy-vline
WA_E1P1222_STR-ITXNR sy-vline
WA_E1P1222_STR-TABNR sy-vline
WA_E1P1222_STR-TABSEQNR sy-vline
WA_E1P1222_STR-ATTRIB sy-vline
WA_E1P1222_STR-LOW sy-vline
WA_E1P1222_STR-HIGH sy-vline
WA_E1P1222_STR-EXCLUDED sy-vline
WA_E1P1222_STR-DEFAULTVAL sy-vline
WA_E1P1222_STR-INHERITED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.