ABAP Select data from SAP table E1P1022 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1P1022 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1P1022. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1P1022 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1P1022 TYPE STANDARD TABLE OF E1P1022,
      WA_E1P1022 TYPE E1P1022,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1P1022> TYPE E1P1022.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1P1022.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1P1022
  INTO TABLE IT_E1P1022.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1P1022
*  INTO TABLE @DATA(IT_E1P10222).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1P1022 INDEX 1 INTO DATA(WA_E1P10222).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1P1022 ASSIGNING <E1P1022>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1P1022>-MANDT = 1.
<E1P1022>-PLVAR = 1.
<E1P1022>-OTYPE = 1.
<E1P1022>-OBJID = 1.
<E1P1022>-INFTY = 1.
ENDLOOP.

LOOP AT IT_E1P1022 INTO WA_E1P1022.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1P1022-SUBTY, sy-vline,
WA_E1P1022-ISTAT, sy-vline,
WA_E1P1022-PRIOX, sy-vline,
WA_E1P1022-BEGDA, sy-vline,
WA_E1P1022-ENDDA, sy-vline,
WA_E1P1022-VARYF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1P1022 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1P1022 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1P1022 INTO WA_E1P1022. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1P1022_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
PRIOX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
ACLAS TYPE STRING,
AMUST TYPE STRING,
REFAK TYPE STRING,
BGDAY TYPE STRING,
RDAY1 TYPE STRING,
RDAY2 TYPE STRING,
RDAY3 TYPE STRING,
RDAY4 TYPE STRING,
RDAYL TYPE STRING,
REFRQ TYPE STRING,
NDAYS TYPE STRING,
NHOURS TYPE STRING,
TAGNR_001 TYPE STRING,
ZBLID_001 TYPE STRING,
TAGNR_002 TYPE STRING,
ZBLID_002 TYPE STRING,
TAGNR_003 TYPE STRING,
ZBLID_003 TYPE STRING,
TAGNR_004 TYPE STRING,
ZBLID_004 TYPE STRING,
TAGNR_005 TYPE STRING,
ZBLID_005 TYPE STRING,
TAGNR_006 TYPE STRING,
ZBLID_006 TYPE STRING,
TAGNR_007 TYPE STRING,
ZBLID_007 TYPE STRING,
TAGNR_008 TYPE STRING,
ZBLID_008 TYPE STRING,
TAGNR_009 TYPE STRING,
ZBLID_009 TYPE STRING,
TAGNR_010 TYPE STRING,
ZBLID_010 TYPE STRING,
TAGNR_011 TYPE STRING,
ZBLID_011 TYPE STRING,
TAGNR_012 TYPE STRING,
ZBLID_012 TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1P1022_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1P1022_STR-MANDT sy-vline
WA_E1P1022_STR-PLVAR sy-vline
WA_E1P1022_STR-OTYPE sy-vline
WA_E1P1022_STR-OBJID sy-vline
WA_E1P1022_STR-INFTY sy-vline
WA_E1P1022_STR-SUBTY sy-vline
WA_E1P1022_STR-ISTAT sy-vline
WA_E1P1022_STR-PRIOX sy-vline
WA_E1P1022_STR-BEGDA sy-vline
WA_E1P1022_STR-ENDDA sy-vline
WA_E1P1022_STR-VARYF sy-vline
WA_E1P1022_STR-SEQNR sy-vline
WA_E1P1022_STR-AEDTM sy-vline
WA_E1P1022_STR-UNAME sy-vline
WA_E1P1022_STR-REASN sy-vline
WA_E1P1022_STR-HISTO sy-vline
WA_E1P1022_STR-ITXNR sy-vline
WA_E1P1022_STR-ACLAS sy-vline
WA_E1P1022_STR-AMUST sy-vline
WA_E1P1022_STR-REFAK sy-vline
WA_E1P1022_STR-BGDAY sy-vline
WA_E1P1022_STR-RDAY1 sy-vline
WA_E1P1022_STR-RDAY2 sy-vline
WA_E1P1022_STR-RDAY3 sy-vline
WA_E1P1022_STR-RDAY4 sy-vline
WA_E1P1022_STR-RDAYL sy-vline
WA_E1P1022_STR-REFRQ sy-vline
WA_E1P1022_STR-NDAYS sy-vline
WA_E1P1022_STR-NHOURS sy-vline
WA_E1P1022_STR-TAGNR_001 sy-vline
WA_E1P1022_STR-ZBLID_001 sy-vline
WA_E1P1022_STR-TAGNR_002 sy-vline
WA_E1P1022_STR-ZBLID_002 sy-vline
WA_E1P1022_STR-TAGNR_003 sy-vline
WA_E1P1022_STR-ZBLID_003 sy-vline
WA_E1P1022_STR-TAGNR_004 sy-vline
WA_E1P1022_STR-ZBLID_004 sy-vline
WA_E1P1022_STR-TAGNR_005 sy-vline
WA_E1P1022_STR-ZBLID_005 sy-vline
WA_E1P1022_STR-TAGNR_006 sy-vline
WA_E1P1022_STR-ZBLID_006 sy-vline
WA_E1P1022_STR-TAGNR_007 sy-vline
WA_E1P1022_STR-ZBLID_007 sy-vline
WA_E1P1022_STR-TAGNR_008 sy-vline
WA_E1P1022_STR-ZBLID_008 sy-vline
WA_E1P1022_STR-TAGNR_009 sy-vline
WA_E1P1022_STR-ZBLID_009 sy-vline
WA_E1P1022_STR-TAGNR_010 sy-vline
WA_E1P1022_STR-ZBLID_010 sy-vline
WA_E1P1022_STR-TAGNR_011 sy-vline
WA_E1P1022_STR-ZBLID_011 sy-vline
WA_E1P1022_STR-TAGNR_012 sy-vline
WA_E1P1022_STR-ZBLID_012 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.