ABAP Select data from SAP table E1P0665 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1P0665 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1P0665. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1P0665 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1P0665 TYPE STANDARD TABLE OF E1P0665,
      WA_E1P0665 TYPE E1P0665,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1P0665> TYPE E1P0665.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1P0665.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1P0665
  INTO TABLE IT_E1P0665.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1P0665
*  INTO TABLE @DATA(IT_E1P06652).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1P0665 INDEX 1 INTO DATA(WA_E1P06652).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1P0665 ASSIGNING <E1P0665>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1P0665>-PERNR = 1.
<E1P0665>-INFTY = 1.
<E1P0665>-SUBTY = 1.
<E1P0665>-OBJPS = 1.
<E1P0665>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_E1P0665 INTO WA_E1P0665.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1P0665-ENDDA, sy-vline,
WA_E1P0665-BEGDA, sy-vline,
WA_E1P0665-SEQNR, sy-vline,
WA_E1P0665-AEDTM, sy-vline,
WA_E1P0665-UNAME, sy-vline,
WA_E1P0665-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1P0665 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1P0665 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1P0665 INTO WA_E1P0665. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1P0665_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
STATUS01 TYPE STRING,
STATUS01_DAT TYPE STRING,
STATUS02 TYPE STRING,
STATUS02_DAT TYPE STRING,
EMFSL TYPE STRING,
REGNRPUO TYPE STRING,
CIRCUIT TYPE STRING,
OVERDRACHT_DAT TYPE STRING,
OVERDRACHT_WRD TYPE STRING,
TERUGFACTOR TYPE STRING,
OVERDRACHT_WRDF TYPE STRING,
BET01 TYPE STRING,
BET02 TYPE STRING,
BET03 TYPE STRING,
BET04 TYPE STRING,
BET05 TYPE STRING,
BET06 TYPE STRING,
BET07 TYPE STRING,
BET08 TYPE STRING,
BET09 TYPE STRING,
BET10 TYPE STRING,
KASSE TYPE STRING,
BEG_DP TYPE STRING,
EIND_DP TYPE STRING,
CONTACT_PERS TYPE STRING,
AFWOV_DAT TYPE STRING,
ACC_PARTNR TYPE STRING,
REGNRPUO_LANG TYPE STRING,
CPERS_LANG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1P0665_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1P0665_STR-PERNR sy-vline
WA_E1P0665_STR-INFTY sy-vline
WA_E1P0665_STR-SUBTY sy-vline
WA_E1P0665_STR-OBJPS sy-vline
WA_E1P0665_STR-SPRPS sy-vline
WA_E1P0665_STR-ENDDA sy-vline
WA_E1P0665_STR-BEGDA sy-vline
WA_E1P0665_STR-SEQNR sy-vline
WA_E1P0665_STR-AEDTM sy-vline
WA_E1P0665_STR-UNAME sy-vline
WA_E1P0665_STR-HISTO sy-vline
WA_E1P0665_STR-ITXEX sy-vline
WA_E1P0665_STR-REFEX sy-vline
WA_E1P0665_STR-ORDEX sy-vline
WA_E1P0665_STR-ITBLD sy-vline
WA_E1P0665_STR-PREAS sy-vline
WA_E1P0665_STR-FLAG1 sy-vline
WA_E1P0665_STR-FLAG2 sy-vline
WA_E1P0665_STR-FLAG3 sy-vline
WA_E1P0665_STR-FLAG4 sy-vline
WA_E1P0665_STR-RESE1 sy-vline
WA_E1P0665_STR-RESE2 sy-vline
WA_E1P0665_STR-GRPVL sy-vline
WA_E1P0665_STR-STATUS01 sy-vline
WA_E1P0665_STR-STATUS01_DAT sy-vline
WA_E1P0665_STR-STATUS02 sy-vline
WA_E1P0665_STR-STATUS02_DAT sy-vline
WA_E1P0665_STR-EMFSL sy-vline
WA_E1P0665_STR-REGNRPUO sy-vline
WA_E1P0665_STR-CIRCUIT sy-vline
WA_E1P0665_STR-OVERDRACHT_DAT sy-vline
WA_E1P0665_STR-OVERDRACHT_WRD sy-vline
WA_E1P0665_STR-TERUGFACTOR sy-vline
WA_E1P0665_STR-OVERDRACHT_WRDF sy-vline
WA_E1P0665_STR-BET01 sy-vline
WA_E1P0665_STR-BET02 sy-vline
WA_E1P0665_STR-BET03 sy-vline
WA_E1P0665_STR-BET04 sy-vline
WA_E1P0665_STR-BET05 sy-vline
WA_E1P0665_STR-BET06 sy-vline
WA_E1P0665_STR-BET07 sy-vline
WA_E1P0665_STR-BET08 sy-vline
WA_E1P0665_STR-BET09 sy-vline
WA_E1P0665_STR-BET10 sy-vline
WA_E1P0665_STR-KASSE sy-vline
WA_E1P0665_STR-BEG_DP sy-vline
WA_E1P0665_STR-EIND_DP sy-vline
WA_E1P0665_STR-CONTACT_PERS sy-vline
WA_E1P0665_STR-AFWOV_DAT sy-vline
WA_E1P0665_STR-ACC_PARTNR sy-vline
WA_E1P0665_STR-REGNRPUO_LANG sy-vline
WA_E1P0665_STR-CPERS_LANG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.